Six-Minute Walk Test and Cardiopulmonary Exercise Testing in Patients With Chronic Heart Failure: A Comparative Analysis on Clinical and Prognostic Insights
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Background— The six-minute walk test (6MWT) and cardiopulmonary exercise testing (CPET) are the 2 testing modalities most broadly used for assessing functional limitation in patients with heart failure (HF). A comprehensive comparison on clinical and prognostic validity of the 2 techniques has not been performed and is the aim of the present investigation. Methods and Results— Two hundred fifty-three patients diagnosed with systolic (n=211) or diastolic (n=42) HF (age: 61.9�10.1 years; New York Heart Association Class: 2.2�0.78) underwent a 6MWT and a symptom-limited CPET evaluation and were prospectively followed up. During the 4-year tracking period, there were 43 cardiac-related deaths with an annual cardiac mortality rate of 8.7%. The 6MWT distance correlated with CPET-derived variables (ie, peak V o 2 , V o 2 at anaerobic threshold, and V e /V co 2 slope) and was significantly reduced in proportion with lower peak V o 2 and higher V e /V co 2 slope classes and presence of an exercise oscillatory breathing (EOB) pattern ( P <0.01). However, no significant differences were observed in distance covered between survivors and nonsurvivors (353.2�95.8 m versus 338.5�76.4 m; P =NS). At univariate and multivariate Cox proportional analyses, the association of the 6MWT distance with survival was not significant either as a continuous or dicotomized variable (≤300 m). Conversely, CPET-derived variables emerged as prognostic with the strongest association found for EOB (systolic HF) and V e /V co 2 slope (entire population with HF and patients with a 6MWT≤300 m). Conclusions— The 6MWT is confirmed to be a simple and reliable first-line test for quantification of exercise intolerance in patients with HF. However, there is no supportive evidence for its use as a prognostic marker in alternative to or in conjunction with CPET-derived variables.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ATS Statement: Guidelines for the Six-Minute Walk Test
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.166.1.at1102 · Cited by 11,195
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Nagueh, S. F., Middleton, K. J., Kopelen, H. A., Zoghbi, W. A., & Quiñones, M. A. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00344-6 · Cited by 3,029
Paulus, W. J., Tschöpe, C., Sanderson, J. E., Rusconi, C., Flachskampf, F. A., Rademakers, F. E., Marino, P., Smiseth, O. A., De Keulenaer, G., Leite-Moreira, A. F., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm037 · Cited by 2,679
Self-citationCahalin, L. P., Mathier, M. A., Semigran, M. J., Dec, G. W., & DiSalvo, T. G. (1996) · Chest · doi:10.1378/chest.110.2.325 · Cited by 762
Bittner, V. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510140062030 · Cited by 711
How to diagnose diastolic heart failure
Paulus, W. J., Brutsaert, D. L., Gillebert, T. C., Rademakers, F., Stanislas, U., Leite-Moreira, A. F., Om, H., Zh, J., Kaufmann, P. A., Mandinov, L., et al. (1998) · Ghent University Academic Bibliography (Ghent University) · Cited by 649
Kasner, M., Westermann, D., Steendijk, P., Gaub, R., Wilkenshoff, U., Weitmann, K., Hoffmann, W., Poller, W., Schultheiss, H.-P., Pauschinger, M., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.661983 · Cited by 565
Chua, T. P., Ponikowski, P., Harrington, D., Anker, S. D., Webb-Peploe, K., Clark, A. L., Poole-Wilson, P. A., & Coats, A. J. S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00078-8 · Cited by 563
Abraham, W. T., Young, J. B., León, A. R., Adler, S., Bank, A. J., Hall, S. A., Lieberman, R., Liem, L. B., O’Connell, J. B., Schroeder, J. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000146336.92331.d1 · Cited by 559
Cited by
Crespo-Leiro, M. G., Metra, M., Lund, L. H., Milicic, D., Costanzo, M. R., Filippatos, G., Gustafsson, F., Tsui, S., Barge-Caballero, E., De Jonge, N., et al. (2018) · European Journal of Heart Failure · doi:10.1002/ejhf.1236 · Cited by 880
Exercise Intolerance in Patients With Heart Failure
Del Buono, M. G., Arena, R., Borlaug, B. A., Carbone, S., Canada, J. M., Kirkman, D. L., Garten, R., Rodriguez-Miguelez, P., Guazzi, M., Lavie, C. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.072 · Cited by 477
“An early study demonstrated that a 6MWT distance <300 m is an independent prognostic marker of subsequent CV death in patients with NYHA functional class II to III heart failure with reduced left ventricular ejection fraction (HFrEF) (16), but more recent studies have provided conflicting data in patients with HF, inc…”
BackgroundSelf-citation6-minute walking test: a useful tool in the management of heart failure patients
Giannitsi, S., Bougiakli, M., Bechlioulis, A., Kotsia, A., Michalis, L. K., & Naka, K. K. (2019) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/1753944719870084 · Cited by 375
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Forman, D. E., Fleg, J. L., Kitzman, D. W., Brawner, C. A., Swank, A. M., McKelvie, R. S., Clare, R. M., Ellis, S. J., Dunlap, M. E., & Bittner, V. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.08.1010 · Cited by 220
“Oscillatory expiratory breathing, end-tidal partial pressure of carbon dioxide, VE/VO2 ratios, recovery gas exchange dynamics, and heart rate and blood pressure responses are among an extensive array of CPX assessments that can be used to enhance prognostic assessment (1,2,38).”
BackgroundBeatty, A. L., Schiller, N. B., & Whooley, M. A. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2012.2198 · Cited by 174
“The results of this study also expand beyond previous studies that have investigated the 6MWT in patients with heart failure.(13-17,31) Although 6MWT distance did not reliably correlate with cardiopulmonary exercise testingmeasures inprevious studies,(31,32) most studies found that the 6MWT still predicted hospitaliza…”
Cahalin, L. P., Arena, R., Labate, V., Bandera, F., & Guazzi, M. (2014) · European Journal of Preventive Cardiology · doi:10.1177/2047487313475892 · Cited by 11
Self-citation
Metadata
- Authors
- Guazzi, M., Dickstein, K., Vicenzi, M., & Arena, R.
- Venue
- Circulation: Heart Failure
- Published
- 2009-11
- Volume
- 2
- Issue
- 6
- Pages
- 549-555
- ISSN
- 1941-3289 (ISSN-L)
- 1941-3297
- OpenAlex
- W2155366163
- Cited by
- 223
- References
- 35
- FWCI
- 17.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.