CoChat

Resting Ventricular–Vascular Function and Exercise Capacity in Heart Failure With Preserved Ejection Fraction: A RELAX Trial Ancillary Study

Open access
Mohammed, Selma F., Borlaug, Barry A., McNulty, Steven, Lewis, Gregory D., Lin, Grace, Zakeri, Rosita, Semigran, Marc J., LeWinter, Martin, Hernandez, Adrian F., Braunwald, Eugene, Redfield, Margaret M. · 2014 · Circulation: Heart Failure
Cited by 48

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Background—: Exercise intolerance is a hallmark of heart failure, but factors associated with impaired exercise capacity in heart failure with preserved ejection fraction are unclear. We hypothesized that in heart failure with preserved ejection fraction, the severity of resting ventricular and vascular dysfunction are associated with impairment in exercise tolerance as assessed by peak oxygen consumption. Methods and Results—: Subjects with heart failure with preserved ejection fraction enrolled in the PhosphodiesteRasE-5 Inhibition to Improve CLinical Status And EXercise Capacity in Diastolic Heart Failure (RELAX) clinical trial (n=216) underwent baseline Doppler echocardiography, cardiopulmonary exercise testing, and cardiac MRI. RELAX participants were elderly (median age 69 years) and 48% were women. Ejection fraction (60%) and stroke volume (77 mL) were normal, while diastolic dysfunction (medial E / e ′, 16; deceleration time, 185 ms; left atrial volume, 44 mL/m 2 ) and increased arterial load (arterial elastance, 1.51 mm Hg/mL) were evident. Peak oxygen consumption was reduced (11.7 mLkg −1 min −1 , 1141 mL/min) and age, sex, body mass index, hemoglobin, and chronotropic response collectively explained 64% of the variance in raw peak oxygen consumption (mL/min). After adjustment for these variables, left ventricular structure (diastolic dimension [1.5%, P =0.008] and left ventricular mass [1.6%, P =0.008]), resting stroke volume (2.0%, P =0.002), left ventricular diastolic dysfunction (deceleration time [0.9%, P =0.03] and E / e ′ [1.4%, P =0.009]), and arterial function (arterial elastance [2.1%, P =0.002] and systemic arterial compliance [1.5%, P =0.007]), each explained only a small additional portion of the variance in peak oxygen consumption. Conclusions—: In heart failure with preserved ejection fraction, potentially modifiable factors (obesity, anemia, and chronotropic incompetence) are strongly associated with exercise capacity, whereas resting measures of ventricular and vascular structure and function are not. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT00763867

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circheartfailure.114.001192

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Mohammed, S. F., Borlaug, B. A., McNulty, S., Lewis, G. D., Lin, G., Zakeri, R., Semigran, M. J., LeWinter, M., Hernandez, A. F., Braunwald, E., & Redfield, M. M.
Venue
Circulation: Heart Failure
Published
2014-07
Volume
7
Issue
4
Pages
580-589
ISSN
  • 1941-3289 (ISSN-L)
  • 1941-3297
OpenAlex
W2050585111
Cited by
48
References
11
FWCI
12.41
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.