Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 177

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Noninvasive Vascular Function Measurement in the Community: Cross-Sectional Relations and Comparison of Methods

Schnabel, Renate B., Schulz, Andreas, Wild, Philipp S., Sinning, Christoph R., Wilde, Sandra, Eleftheriadis, Medea, Herkenhoff, Stephanie, Zeller, Tanja, Lubos, Edith, Lackner, Karl J., Warnholtz, Ascan, Gori, Tommaso, Blankenberg, Stefan, Münzel, Thomas · 2011 · Circulation: Cardiovascular Imaging

Abstract

Background—: Several methods of noninvasive vascular function testing have been suggested for cardiovascular risk screening in the community. A direct comparison of the different methods and their relation to classical cardiovascular risk factors in a large cohort is missing. Methods and Results—: In 5000 individuals (mean age, 55.5±10.9 years; age range, 35 to 74 years; women, 49.2%) of the population-based Gutenberg Heart Study, we performed simultaneous measurement of flow-mediated dilation (FMD) and peripheral arterial volume pulse determined by infrared photo (reflection index) and pneumatic plethysmography (PAT) and explored their associations. All function measures were recorded at baseline and after reactive hyperemia induced by 5-minute brachial artery occlusion. Correlations between different measures of vascular function were statistically significant but moderate. The strongest association for hyperemic response variables was observed for PAT ratio and FMD (Spearman r =0.17; age- and sex-adjusted partial correlation, 0.068). Classical risk factors explained between 15.8% (baseline reflection index) and 58.4% (brachial artery diameter) of the baseline values but only accounted for 3.2% (reflection index), 15.4% (FMD), and 13.9% (PAT ratio) of the variability of reflective hyperemic response. Regression models varied in their relations to classical risk factors for the individual vascular function measures. Consistently associated with different vascular function methods were age, sex, body mass index, and indicators of hypertension. Peripheral tonometry also showed a relation to fasting glucose concentrations. Conclusions—: Noninvasive measures of conduit artery and peripheral arterial function are modestly correlated, differ in their relation to classical cardiovascular risk factors, and may thus reflect different pathologies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circimaging.110.961557

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 177

Metadata

Authors
Schnabel, R. B., Schulz, A., Wild, P. S., Sinning, C. R., Wilde, S., Eleftheriadis, M., Herkenhoff, S., Zeller, T., Lubos, E., Lackner, K. J., Warnholtz, A., Gori, T., Blankenberg, S., & Münzel, T.
Venue
Circulation: Cardiovascular Imaging
Published
2011-07
Volume
4
Issue
4
Pages
371-380
ISSN
  • 1941-9651 (ISSN-L)
  • 1942-0080
OpenAlex
W2731336454
Cited by
177
References
3
FWCI
11.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Noninvasive Vascular Function Measurement in the Community: Cross-Sectional Relations and Comparison of Methods. https://app.cochat.ai/papers/10.1161/circimaging.110.961557
The paper
Schnabel, R. B., Schulz, A., Wild, P. S., Sinning, C. R., Wilde, S., Eleftheriadis, M., Herkenhoff, S., Zeller, T., Lubos, E., Lackner, K. J., Warnholtz, A., Gori, T., Blankenberg, S., & Münzel, T. (2011). Noninvasive Vascular Function Measurement in the Community: Cross-Sectional Relations and Comparison of Methods. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.110.961557

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.