Improved Left Ventricular Mass Quantification With Partial Voxel Interpolation: In Vivo and Necropsy Validation of a Novel Cardiac MRI Segmentation Algorithm
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background—: Cardiac magnetic resonance (CMR) typically quantifies LV mass (LVM) by means of manual planimetry (MP), but this approach is time-consuming and does not account for partial voxel components— myocardium admixed with blood in a single voxel. Automated segmentation (AS) can account for partial voxels, but this has not been used for LVM quantification. This study used automated CMR segmentation to test the influence of partial voxels on quantification of LVM. Methods and Results—: LVM was quantified by AS and MP in 126 consecutive patients and 10 laboratory animals undergoing CMR. AS yielded both partial voxel (AS PV ) and full voxel (AS FV ) measurements. Methods were independently compared with LVM quantified on echocardiography (echo) and an ex vivo standard of LVM at necropsy. AS quantified LVM in all patients, yielding a 12-fold decrease in processing time versus MP (0:21±0:04 versus 4:18±1:02 minutes; P <0.001). AS FV mass (136±35 g) was slightly lower than MP (139±35; Δ=3±9 g, P <0.001). Both methods yielded similar proportions of patients with LV remodeling ( P =0.73) and hypertrophy ( P =1.00). Regarding partial voxel segmentation, AS PV yielded higher LVM (159±38 g) than MP (Δ=20±10 g) and AS FV (Δ=23±6 g, both P <0.001), corresponding to relative increases of 14% and 17%. In multivariable analysis, magnitude of difference between AS PV and AS FV correlated with larger voxel size (partial r =0.37, P <0.001) even after controlling for LV chamber volume ( r =0.28, P =0.002) and total LVM ( r =0.19, P =0.03). Among patients, AS PV yielded better agreement with echo (Δ=20±25 g) than did AS FV (Δ=43±24 g) or MP (Δ=40±22 g, both P <0.001). Among laboratory animals, AS PV and ex vivo results were similar (Δ=1±3 g, P =0.3), whereas AS FV (6±3 g, P <0.001) and MP (4±5 g, P =0.02) yielded small but significant differences with LVM at necropsy. Conclusions—: Automated segmentation of myocardial partial voxels yields a 14–17% increase in LVM versus full voxel segmentation, with increased differences correlated with lower spatial resolution. Partial voxel segmentation yields improved CMR agreement with echo and necropsy-verified LVM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Cited by
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K., Cloutier, L., Gelfer, M., Lamarre-Cliche, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 684
Metadata
- Authors
- Codella, N. C. F., Lee, H. Y., Fieno, D. S., Chen, D. W., Hurtado-Rua, S., Kochar, M., Finn, J. P., Judd, R., Goyal, P., Schenendorf, J., Cham, M. D., Devereux, R. B., Prince, M., Wang, Y., & Weinsaft, J. W.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2012-01
- Volume
- 5
- Issue
- 1
- Pages
- 137-146
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2155396404
- Cited by
- 56
- References
- 1
- FWCI
- 3.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Left Ventricular Mass Quantification With Partial Voxel Interpolation: In Vivo and Necropsy Validation of a Novel Cardiac MRI Segmentation Algorithm. https://app.cochat.ai/papers/10.1161/circimaging.111.966754
- The paper
- Codella, N. C. F., Lee, H. Y., Fieno, D. S., Chen, D. W., Hurtado-Rua, S., Kochar, M., Finn, J. P., Judd, R., Goyal, P., Schenendorf, J., Cham, M. D., Devereux, R. B., Prince, M., Wang, Y., & Weinsaft, J. W. (2012). Improved Left Ventricular Mass Quantification With Partial Voxel Interpolation: In Vivo and Necropsy Validation of a Novel Cardiac MRI Segmentation Algorithm. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.111.966754
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.