The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Cognitive Machine-Learning Algorithm for Cardiac Imaging: A Pilot Study for Differentiating Constrictive Pericarditis From Restrictive Cardiomyopathy
Open accessAbstract
Background—: Associating a patient’s profile with the memories of prototypical patients built through previous repeat clinical experience is a key process in clinical judgment. We hypothesized that a similar process using a cognitive computing tool would be well suited for learning and recalling multidimensional attributes of speckle tracking echocardiography data sets derived from patients with known constrictive pericarditis and restrictive cardiomyopathy. Methods and Results—: Clinical and echocardiographic data of 50 patients with constrictive pericarditis and 44 with restrictive cardiomyopathy were used for developing an associative memory classifier–based machine-learning algorithm. The speckle tracking echocardiography data were normalized in reference to 47 controls with no structural heart disease, and the diagnostic area under the receiver operating characteristic curve of the associative memory classifier was evaluated for differentiating constrictive pericarditis from restrictive cardiomyopathy. Using only speckle tracking echocardiography variables, associative memory classifier achieved a diagnostic area under the curve of 89.2%, which improved to 96.2% with addition of 4 echocardiographic variables. In comparison, the area under the curve of early diastolic mitral annular velocity and left ventricular longitudinal strain were 82.1% and 63.7%, respectively. Furthermore, the associative memory classifier demonstrated greater accuracy and shorter learning curves than other machine-learning approaches, with accuracy asymptotically approaching 90% after a training fraction of 0.3 and remaining flat at higher training fractions. Conclusions—: This study demonstrates feasibility of a cognitive machine-learning approach for learning and recalling patterns observed during echocardiographic evaluations. Incorporation of machine-learning algorithms in cardiac imaging may aid standardized assessments and support the quality of interpretations, particularly for novice readers with limited experience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Neural networks and physical systems with emergent collective computational abilities.
Hopfield, J. J. (1982) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.79.8.2554 · Cited by 19,270
Bellman, R. E. (2010) · doi:10.1515/9781400835386 · Cited by 14,588
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
Recommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Recommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Identification of ischemic heart disease via machine learning analysis on magnetocardiograms
Tantimongcolwat, T., Naenna, T., Isarankura-Na-Ayudhya, C., Embrechts, M. J., & Prachayasittikul, V. (2008) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2008.04.009 · Cited by 57
Cited by
Artificial Intelligence in Precision Cardiovascular Medicine
Krittanawong, C., Zhang, H., Wang, Z., Aydar, M., & Kitai, T. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.03.571 · Cited by 1,120
Fast and accurate view classification of echocardiograms using deep learning
Madani, A., Arnaout, R., Mofrad, M., & Arnaout, R. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0013-1 · Cited by 585
Machine learning in cardiovascular medicine: are we there yet?
Shameer, K., Johnson, K. W., Glicksberg, B. S., Dudley, J. T., & Sengupta, P. P. (2018) · Heart · doi:10.1136/heartjnl-2017-311198 · Cited by 555
Self-citationAl’Aref, S. J., Anchouche, K., Singh, G., Slomka, P. J., Kolli, K. K., Kumar, A., Pandey, M., Maliakal, G., van Rosendael, A. R., Beecy, A. N., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy404 · Cited by 534
Narang, A., Bae, R., Hong, H., Thomas, Y., Surette, S., Cadieu, C., Chaudhry, A., Martin, R. P., McCarthy, P. M., Rubenson, D. S., et al. (2021) · JAMA Cardiology · doi:10.1001/jamacardio.2021.0185 · Cited by 442
Narula, S., Shameer, K., Salem Omar, A. M., Dudley, J. T., & Sengupta, P. P. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.08.062 · Cited by 410
Self-citationDeep Learning for Prediction of Obstructive Disease From Fast Myocardial Perfusion SPECT
Betancur, J., Commandeur, F., Motlagh, M., Sharir, T., Einstein, A. J., Bokhari, S., Fish, M. B., Ruddy, T. D., Kaufmann, P., Sinusas, A. J., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2018.01.020 · Cited by 358
Systems biology in cardiovascular disease: a multiomics approach
Joshi, A., Rienks, M., Theofilatos, K., & Mayr, M. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-020-00477-1 · Cited by 301
Artificial Intelligence in Cardiology: Present and Future
Lopez-Jimenez, F., Attia, Z., Arruda-Olson, A. M., Carter, R., Chareonthaitawee, P., Jouni, H., Kapa, S., Lerman, A., Luong, C., Medina-Inojosa, J. R., et al. (2020) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2020.01.038 · Cited by 280
Artificial intelligence and echocardiography
Alsharqi, M., Woodward, W. J., Mumith, J. A., Markham, D. C., Upton, R., & Leeson, P. (2018) · Echo Research & Practice · doi:10.1530/erp-18-0056 · Cited by 262
khan, Z. F., & Alotaibi, S. R. (2020) · Journal of Healthcare Engineering · doi:10.1155/2020/8894694 · Cited by 235
Application of mobile health, telemedicine and artificial intelligence to echocardiography
Seetharam, K., Kagiyama, N., & Sengupta, P. P. (2019) · Echo Research & Practice · doi:10.1530/erp-18-0081 · Cited by 111
Self-citationApplications of Artificial Intelligence in Cardiology. The Future is Already Here
Dorado-Díaz, P. I., Sampedro-Gómez, J., Vicente-Palacios, V., & Sánchez, P. L. (2019) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2019.05.014 · Cited by 111
Enabling Precision Cardiology Through Multiscale Biology and Systems Medicine
Johnson, K. W., Shameer, K., Glicksberg, B. S., Readhead, B., Sengupta, P. P., Björkegren, J. L. M., Kovacic, J. C., & Dudley, J. T. (2017) · JACC: Basic to Translational Science · doi:10.1016/j.jacbts.2016.11.010 · Cited by 83
“Furthermore, machine learning methods have already been successfully applied to echocardiography results (41,42).”
BackgroundMethodSelf-citationArtificial Intelligence in Cardiovascular Medicine
Seetharam, K., Shrestha, S., & Sengupta, P. P. (2019) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-019-0728-1 · Cited by 76
Self-citationHanneman, K., Playford, D., Dey, D., van Assen, M., Mastrodicasa, D., Cook, T. S., Gichoya, J. W., Williamson, E. E., Rubin, G. D., & on behalf of the American Heart Association Council on Cardiovascular Radiology and Intervention; and Council on Lifelong Congenital Heart Disease and Heart Health in the Young (2024) · Circulation · doi:10.1161/cir.0000000000001202 · Cited by 72
Will Artificial Intelligence Replace the Human Echocardiographer?: Clinical Considerations
Sengupta, P. P., & Adjeroh, D. A. (2018) · Circulation · doi:10.1161/circulationaha.118.037095 · Cited by 50
Self-citationCharting the Unseen: How Non-Invasive Imaging Could Redefine Cardiovascular Prevention
Trimarchi, G., Pizzino, F., Paradossi, U., Gueli, I. A., Palazzini, M., Gentile, P., Di Spigno, F., Ammirati, E., Garascia, A., Tedeschi, A., et al. (2024) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd11080245 · Cited by 45
Metadata
- Authors
- Sengupta, P. P., Huang, Y.-M., Bansal, M., Ashrafi, A., Fisher, M., Shameer, K., Gall, W., & Dudley, J. T.
- Venue
- Circulation: Cardiovascular Imaging
- Published
- 2016-06
- Volume
- 9
- Issue
- 6
- ISSN
- 1941-9651 (ISSN-L)
- 1942-0080
- OpenAlex
- W2413889045
- Cited by
- 203
- References
- 9
- FWCI
- 30.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.