The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Bioabsorbable Coronary Stents
Open accessAbstract
P ercutaneous coronary intervention (PCI) with bioabsorb-able stents has created interest because the need for mechanical support for the healing artery is temporary, and beyond the first few months there are potential disadvantages of a permanent metallic prosthesis.Stents improve immediate outcomes, including profoundly reducing acute vessel occlusion after PCI by scaffolding intimal tissue flaps that have separated from deeper layers and by optimizing vessel caliber.They limit restenosis by preventing negative remodeling. 1 The intimal hyperplastic healing response to PCI that contributes to restenosis, especially after bare metal stenting, can be limited by coating stents with antiproliferative medications.2,3 Potential advantages of having the stent disappear from the treated site include reduced or abolished late stent thrombosis, improved lesion imaging with computed tomography or magnetic resonance, facilitation of repeat treatments (surgical or percutaneous) to the same site, restoration of vasomotion, and freedom from side-branch obstruction by struts and from strut fracture-induced restenosis.Bioabsorbable stents have a potential pediatric role because they allow vessel growth and do not need eventual surgical removal. 2 The progression of stenosis seen within stents 7 to 10 years after stenting has been attributed, at least in part, to inflammation around metallic struts, which might argue for an absorbable stent.3 Progression is also observed late after balloon angioplasty.4 Some patients say they prefer an effective temporary implant rather than a permanent prosthesis.Although the concept of bioabsorbable stents has created interest for Ͼ20 years, there are challenges in making a stent that has sufficient radial strength for an appropriate duration, that does not have unduly thick struts, that can be a drug delivery vehicle, and where degradation does not generate an unacceptable inflammatory response.5,6 We will review the different bioabsorbable stents that have been studied clinically and discuss the duration of the need for mechanical support and the potential amelioration of late stent thrombosis risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morice, M.-C., Serruys, P. W., Sousa, J. E., Fajadet, J., Ban Hayashi, E., Perin, M., Colombo, A., Schuler, G., Barragan, P., Guagliumi, G., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012843 · Cited by 4,033
Self-citationPathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Daemen, J., Wenaweser, P., Tsuchida, K., Abrecht, L., Vaina, S., Morger, C., Kukreja, N., Jüni, P., Sianos, G., Hellige, G., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60314-6 · Cited by 1,757
Self-citationVirmani, R., Guagliumi, G., Farb, A., Musumeci, G., Grieco, N., Motta, T., Mihalcsik, L., Tespili, M., Valsecchi, O., & Kolodgie, F. D. (2004) · Circulation · doi:10.1161/01.cir.0000116202.41966.d4 · Cited by 1,469
Colombo, A., Drzewiecki, J., Banning, A., Grube, E., Hauptmann, K., Silber, S., Dudek, D., Fort, S., Schiele, F., Zmudka, K., et al. (2003) · Circulation · doi:10.1161/01.cir.0000086926.62288.a6 · Cited by 1,016
Serruys, P. W., Luijten, H. E., Beatt, K. J., Geuskens, R., de Feyter, P. J., van den Brand, M., Reiber, J. H., ten Katen, H. J., van Es, G. A., & Hugenholtz, P. G. (1988) · Circulation · doi:10.1161/01.cir.77.2.361 · Cited by 931
Self-citationErbel, R., Di Mario, C., Bartunek, J., Bonnier, J., de Bruyne, B., Eberli, F. R., Erne, P., Haude, M., Heublein, B., Horrigan, M., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60853-8 · Cited by 907
Arterial Remodeling After Coronary Angioplasty: A Serial Intravascular Ultrasound Study
Mintz, G. S., Popma, J. J., Pichard, A. D., Kent, K. M., Satler, L. F., Chiu Wong, S., Hong, M. K., Kovach, J. A., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.1.35 · Cited by 889
Nobuyoshi, M., Kimura, T., Nosaka, H., Mioka, S., Ueno, K., Yokoi, H., Hamasaki, N., Horiuchi, H., & Ohishi, H. (1988) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(88)80046-9 · Cited by 875
Stent Thrombosis in the Modern Era: A Pooled Analysis of Multicenter Coronary Stent Clinical Trials
Cutlip, D. E., Baim, D. S., Ho, K. K. L., Popma, J. J., Lansky, A. J., Cohen, D. J., Carrozza, J. P., Chauhan, M. S., Rodriguez, O., & Kuntz, R. E. (2001) · Circulation · doi:10.1161/01.cir.103.15.1967 · Cited by 855
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Self-citationSerruys, P. W., Ormiston, J. A., Onuma, Y., Regar, E., Gonzalo, N., Garcia-Garcia, H. M., Nieman, K., Bruining, N., Dorange, C., Miquel-Hébert, K., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60325-1 · Cited by 820
Self-citationInitial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Ormiston, J. A., Serruys, P. W., Regar, E., Dudek, D., Thuesen, L., Webster, M. W., Onuma, Y., Garcia-Garcia, H. M., McGreevy, R., & Veldhof, S. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60415-8 · Cited by 712
Self-citationWindecker, S., Serruys, P. W., Wandel, S., Buszman, P., Trznadel, S., Linke, A., Lenk, K., Ischinger, T., Klauss, V., Eberli, F., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61244-1 · Cited by 653
Self-citationIncidence and Correlates of Drug-Eluting Stent Thrombosis in Routine Clinical Practice
Wenaweser, P., Daemen, J., Zwahlen, M., van Domburg, R., Jüni, P., Vaina, S., Hellige, G., Tsuchida, K., Morger, C., Boersma, E., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.006 · Cited by 481
Self-citationWilson, S. H., Fasseas, P., Orford, J. L., Lennon, R. J., Horlocker, T., Charnoff, N. E., Melby, S., & Berger, P. B. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00622-3 · Cited by 460
Bare metal stent restenosis is not a benign clinical entity
Chen, M. S., John, J. M., Chew, D. P., Lee, D. S., Ellis, S. G., & Bhatt, D. L. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.08.011 · Cited by 413
Coronary syndromes following aspirin withdrawal
Ferrari, E., Benhamou, M., Cerboni, P., & Marcel, B. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.11.041 · Cited by 389
Indication of long-term endothelial dysfunction after sirolimus-eluting stent implantation
Hofma, S. H., van der Giessen, W. J., van Dalen, B. M., Lemos, P. A., McFadden, E. P., Sianos, G., Ligthart, J. M. R., van Essen, D., de Feyter, P. J., & Serruys, P. W. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi571 · Cited by 384
Self-citationSirolimus-Eluting Stents Associated With Paradoxic Coronary Vasoconstriction
Togni, M., Windecker, S., Cocchia, R., Wenaweser, P., Cook, S., Billinger, M., Meier, B., & Hess, O. M. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.01.062 · Cited by 373
Zartner, P., Cesnjevar, R., Singer, H., & Weyand, M. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20520 · Cited by 347
Serruys, P. W. J. C., Ruygrok, P., Neuzner, J., Piek, J. J., Seth, A., Schofer, J. J., Richardt, G., Wiemer, M., Carrié, D., Thuesen, L., et al. (2006) · PubMed · Cited by 346
Self-citationLate Coronary Stent Thrombosis
Windecker, S., & Meier, B. (2007) · Circulation · doi:10.1161/circulationaha.106.683995 · Cited by 226
Grube, E., Sonoda, S., Ikeno, F., Honda, Y., Kar, S., Chan, C., Gerckens, U., Lansky, A. J., & Fitzgerald, P. J. (2004) · Circulation · doi:10.1161/01.cir.0000128850.84227.fd · Cited by 191
Stone, G. W., Ellis, S. G., Colombo, A., Dawkins, K. D., Grube, E., Cutlip, D. E., Friedman, M., Baim, D. S., & Koglin, J. (2007) · Circulation · doi:10.1161/circulationaha.106.687186 · Cited by 181
Mario, C. D., Gil, R. J., Camenzind, E., Ozaki, Y., von Birgelen, C., Umans, V. A. W. M., de Jaegere, P. P. T., de Feyter, P. J., Roelandt, J. R. T. C., & Serruys, P. W. J. C. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80409-3 · Cited by 156
Self-citationTanimoto, S., Serruys, P. W. J. C., Thuesen, L., Dudek, D., Bruyne, B. D., Chevalier, B., & Ormiston, J. A. (2007) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.21136 · Cited by 151
Self-citationBiodegradable stents: they do their job and disappear.
Waksman, R. (2006) · PubMed · Cited by 141
Haplotype-Specific Effects on Endothelial NO Synthase Promoter Efficiency
Wang, J., Dudley, D., & Wang, X. L. (2002) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000016248.51577.1f · Cited by 136
Late Regression of the Dilated Site After Coronary Angioplasty
Ormiston, J. A., Stewart, F. M., Roche, A., Webber, B. J., Whitlock, R. M. L., & Webster, M. W. I. (1997) · Circulation · doi:10.1161/01.cir.96.2.468 · Cited by 69
Self-citationCurrent Status of Biodegradable Stents
Tanguay, J. F., Zidar, J. P., Phillips, H. R., & Stack, R. S. (1994) · Cardiology Clinics · doi:10.1016/s0733-8651(18)30086-9 · Cited by 63
Cited by
Polylactic acid (PLA) controlled delivery carriers for biomedical applications
Tyler, B., Gullotti, D., Mangraviti, A., Utsuki, T., & Brem, H. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.06.018 · Cited by 1,050
Venezuela, J., & Dargusch, M. S. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.01.035 · Cited by 588
Serruys, P. W., Onuma, Y., Dudek, D., Smits, P. C., Koolen, J., Chevalier, B., de Bruyne, B., Thuesen, L., McClean, D., van Geuns, R.-J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.05.050 · Cited by 525
Self-citationOnuma, Y., & Serruys, P. W. (2011) · Circulation · doi:10.1161/circulationaha.110.971606 · Cited by 434
Self-citationCurrent status and outlook on the clinical translation of biodegradable metals
Han, H.-S., Loffredo, S., Jun, I., Edwards, J., Kim, Y.-C., Seok, H.-K., Witte, F., Mantovani, D., & Glyn-Jones, S. (2019) · Materials Today · doi:10.1016/j.mattod.2018.05.018 · Cited by 423
Metadata
- Authors
- Ormiston, J. A., & Serruys, P. W. S.
- Venue
- Circulation: Cardiovascular Interventions
- Published
- 2009-06
- Volume
- 2
- Issue
- 3
- Pages
- 255-260
- ISSN
- 1941-7632 (ISSN-L)
- 1941-7640
- OpenAlex
- W2084529035
- Cited by
- 305
- References
- 32
- FWCI
- 13.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.