CoChat

Device Therapy of Hypertension

Open access
Mahfoud, Felix, Schlaich, Markus P., Lobo, Melvin D. · 2021 · Circulation Research
Cited by 60

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

In the past decade, efforts to improve blood pressure control have looked beyond conventional approaches of lifestyle modification and drug therapy to embrace interventional therapies. Based upon animal and human studies clearly demonstrating a key role for the sympathetic nervous system in the etiology of hypertension, the newer technologies that have emerged are predominantly aimed at neuromodulation of peripheral nervous system targets. These include renal denervation, baroreflex activation therapy, endovascular baroreflex amplification therapy, carotid body ablation, and pacemaker-mediated programmable hypertension control. Of these, renal denervation is the most mature, and with a recent series of proof-of-concept trials demonstrating the safety and efficacy of radiofrequency and more recently ultrasound-based renal denervation, this technology is poised to become available as a viable treatment option for hypertension in the foreseeable future. With regard to baroreflex activation therapy, endovascular baroreflex amplification, carotid body ablation, and programmable hypertension control, these are developing technologies for which more human data are required. Importantly, central nervous system control of the circulation remains a poorly understood yet vital component of the hypertension pathway and mandates further investigation. Technology to improve blood pressure control through deep brain stimulation of key cardiovascular control territories is, therefore, of interest. Furthermore, alternative nonsympathomodulatory intervention targeting the hemodynamics of the circulation may also be worth exploring for patients in whom sympathetic drive is less relevant to hypertension perpetuation. Herein, we review the aforementioned technologies with an emphasis on the preclinical data that underpin their rationale and the human evidence that supports their use.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circresaha.121.318091

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Cited by

See all 60

Metadata

Authors
Mahfoud, F., Schlaich, M. P., & Lobo, M. D.
Venue
Circulation Research
Published
2021-04-02
Volume
128
Issue
7
Pages
1080-1099
ISSN
  • 0009-7330 (ISSN-L)
  • 1524-4571
OpenAlex
W3147555793
Cited by
60
References
24
FWCI
6.26
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Device Therapy of Hypertension. https://app.cochat.ai/papers/10.1161/circresaha.121.318091
The paper
Mahfoud, F., Schlaich, M. P., & Lobo, M. D. (2021). Device Therapy of Hypertension. Circulation Research. https://doi.org/10.1161/circresaha.121.318091

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.