Percutaneous Implantation of the CoreValve Self-Expanding Valve Prosthesis in High-Risk Patients With Aortic Valve Disease: The Siegburg First-in-Man Study
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background— The morbidity and mortality of surgical aortic valve replacement are increased in elderly patients with multiple high-risk comorbid conditions. Therefore, a prospective, single-center, nonrandomized study was performed in high-risk patients with aortic valve disease to evaluate the feasibility and safety of percutaneous implantation of a novel self-expanding aortic valve bioprosthesis (CoreValve). Methods and Results— Symptomatic high-risk patients with an aortic valve area <1 cm 2 were considered for enrollment. CoreValve implantation was performed under general anesthesia with extracorporeal support using the retrograde approach. Clinical follow-up and transthoracic echocardiography were performed after the procedure and at days 15 and 30 after device implantation to evaluate short-term patient and device outcomes. A total of 25 patients with symptomatic aortic valve stenosis (mean gradient before implantation, 44.2±10.8 mm Hg) and multiple comorbidities (median logistic EuroScore, 11.0%) were enrolled. Device success and procedural success were achieved in 22 (88%) and 21 (84%) patients, respectively. Successful device implantation resulted in a marked reduction in the aortic valve gradients (mean gradient after implantation, 12.4±3.0 mm Hg; P <0.0001). The mean aortic regurgitation grade was unchanged. Major in-hospital cardiovascular and cerebral events occurred in 8 patients (32%), including mortality in 5 patients (20%). Among 18 patients with device success surviving to discharge, no adverse events occurred within 30 days after leaving the hospital. Conclusions— Percutaneous implantation of the self-expanding CoreValve aortic valve prosthesis in high-risk patients with aortic stenosis with or without aortic regurgitation is feasible and, when successful, results in marked hemodynamic and clinical improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iung, B. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00201-x · Cited by 3,530 · cited 1×
“Patient Population Inclusion criteria required all of the following: (1) native aortic valve stenosis with an aortic valve area 1 cm(2) and/or aortic valve regurgitation 3 by echocardiographic measure, (2) echocardiographic aortic valve annulus diameter 20 mm and 23 mm, (3) diameter of the ascending aorta 3 cm above t…”
BackgroundCribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Roques, F. (1999) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(99)00106-2 · Cited by 1,759
Percutaneous Aortic Valve Implantation Retrograde From the Femoral Artery
Webb, J. G., Chandavimol, M., Thompson, C. R., Ricci, D. R., Carere, R. G., Munt, B. I., Buller, C. E., Pasupati, S., & Lichtenstein, S. (2006) · Circulation · doi:10.1161/circulationaha.105.582882 · Cited by 900
Treatment of Calcific Aortic Stenosis With the Percutaneous Heart Valve
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Nercolini, D., Tapiero, S., Litzler, P.-Y., Bessou, J.-P., & Babaliaros, V. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.049 · Cited by 715
Cribier, A., Eltchaninoff, H., Tron, C., Bauer, F., Agatiello, C., Sebagh, L., Bash, A., Nusimovici, D., Litzler, P. Y., Bessou, J.-P., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.11.026 · Cited by 644
Observed and relative survival after aortic valve replacement
Kvidal, P., Bergström, P. R., Hörte, L.-G., & Ståhle, E. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00584-7 · Cited by 525
ANDERSEN, H. R., KNUDSEN, L. L., & HASENKAM, J. M. (1992) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a060238 · Cited by 491
Transcatheter Implantation of a Bovine Valve in Pulmonary Position: A Lamb Study
Bonhoeffer, P., Boudjemline, Y., Saliba, Z., Hausse, A. O., Aggoun, Y., Bonnet, D., Sidi, D., & Kachaner, J. (2000) · Circulation · doi:10.1161/01.cir.102.7.813 · Cited by 320
Grube, E., Laborde, J. C., Zickmann, B., Gerckens, U., Felderhoff, T., Sauren, B., Bootsveld, A., Buellesfeld, L., & Iversen, S. (2005) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.20544 · Cited by 251
Self-citationAortic valve replacement for aortic stenosis in persons aged 80 years and over
Culliford, A. T., Galloway, A. C., Colvin, S. B., Grossi, E. A., Baumann, F. G., Esposito, R., Ribakove, G. H., & Spencer, F. C. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90937-g · Cited by 160
Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis
Cribier, A. G., Eltchaninoff, H., & Bash, A. (2003) · ACC Current Journal Review · doi:10.1016/s1062-1458(03)00094-1 · Cited by 152
Bauer, F., Eltchaninoff, H., Tron, C., Lesault, P.-F., Agatiello, C., Nercolini, D., Derumeaux, G., & Cribier, A. (2004) · Circulation · doi:10.1161/01.cir.0000134961.36773.d6 · Cited by 148
Effect of surface coating on platelet count drop during cardiopulmonary bypass
Palanzo, D. A., Zarro, D. L., Manley, N. J., Montesano, R. M., Quinn, M., & Gustafson, P. A. (1999) · Perfusion · doi:10.1177/026765919901400307 · Cited by 46
Cited by
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients
Smith, C. R., Leon, M. B., Mack, M. J., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1103510 · Cited by 6,345
Grube, E., Schuler, G., Buellesfeld, L., Gerckens, U., Linke, A., Wenaweser, P., Sauren, B., Mohr, F.-W., Walther, T., Zickmann, B., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.047 · Cited by 959
Self-citation2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Vahanian, A., Alfieri, O., Al-Attar, N., Antunes, M., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn183 · Cited by 719
Metadata
- Authors
- Grube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., Iversen, S., & Stone, G. W.
- Venue
- Circulation
- Published
- 2006-10-10
- Volume
- 114
- Issue
- 15
- Pages
- 1616-1624
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2073233880
- Cited by
- 655
- References
- 14
- FWCI
- 39.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.