Myocardial Energetics and Efficiency: Current Status of the Noninvasive Approach
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
T he heart is an aerobic organ that relies almost exclusively on the aerobic oxidation of substrates for generation of energy.Consequently, there is close coupling between myocardial oxygen consumption (MV ˙O2 ) and the main determinants of systolic function: heart rate, contractile state, and wall stress. 1 As in any mechanical pump, only part of the energy invested is converted to external power.In the case of the heart, the ratio of useful energy produced (ie, stroke work [SW]) to oxygen consumed is defined as mechanical efficiency, as originally proposed by Bing et al. 2 Under normal conditions this ratio is Ϸ25%, and the residual energy mainly dissipates as heat.3 In pathophysiological disease states, such as heart failure, mechanical efficiency is reduced, and it has been hypothesized that the increased energy expenditure relative to work contributes to progression of the disease.4,5 Moreover, therapeutic interventions that enhance mechanical efficiency have proven to be beneficial with respect to outcome.6 It is therefore desirable to quantify efficiency of the heart to study disease processes and monitor interventions.Both cardiac oxidative metabolism and mechanical work, and thus efficiency, can be quantified through invasive measurements.Although these measurements are accurate and currently considered the gold standard, in clinical practice they are limited because of the need for dual-sided heart catheterization and selective catheterization of the coronary sinus.Recent advances in imaging techniques, however, offer the possibility to noninvasively estimate MV ˙O2 and mechanical work by positron emission tomography and echocardiography or by magnetic resonance imaging, respectively.This review discusses the principles of mechanical efficiency, together with its invasive and noninvasive assessment, as well as their strengths and pitfalls.Finally, results from clinical pathophysiological studies are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bellenger, N. (2000) · European Heart Journal · doi:10.1053/euhj.2000.2011 · Cited by 1,040
Effective arterial elastance as index of arterial vascular load in humans.
Kelly, R. P., Ting, C. T., Yang, T. M., Liu, C. P., Maughan, W. L., Chang, M. S., & Kass, D. A. (1992) · Circulation · doi:10.1161/01.cir.86.2.513 · Cited by 829
Baldasseroni, S., Opasich, C., Gorini, M., Lucci, D., Marchionni, N., Marini, M., Campana, C., Perini, G., Deorsola, A., Masotti, G., et al. (2002) · American Heart Journal · doi:10.1067/mhj.2002.121264 · Cited by 800
Control of myocardial oxygen consumption
Braunwald, E. (1971) · The American Journal of Cardiology · doi:10.1016/0002-9149(71)90439-5 · Cited by 794 · cited 1×
“It is important to realize that 2 stages can be distinguished in the process of MV̇O2 conversion to mechanical energy: (1) efficiency of energy transfer from MV̇O2 to total PVA-area and (2) efficiency of energy transfer from PVA area to EW.”
BackgroundNelson, G. S., Berger, R. D., Fetics, B. J., Talbot, M., Spinelli, J. C., Hare, J. M., & Kass, D. A. (2000) · Circulation · doi:10.1161/01.cir.102.25.3053 · Cited by 758
Suga, H. (1990) · Physiological Reviews · doi:10.1152/physrev.1990.70.2.247 · Cited by 732
Vanoverschelde, J. L., Wijns, W., Depré, C., Essamri, B., Heyndrickx, G. R., Borgers, M., Bol, A., & Melin, J. A. (1993) · Circulation · doi:10.1161/01.cir.87.5.1513 · Cited by 707
Peterson, L. R., Herrero, P., Schechtman, K. B., Racette, S. B., Waggoner, A. D., Kisrieva-Ware, Z., Dence, C., Klein, S., Marsala, J., Meyer, T., et al. (2004) · Circulation · doi:10.1161/01.cir.0000127959.28627.f8 · Cited by 656
Noninvasive single-beat determination of left ventricular end-systolic elastance in humans
Chen, C.-H., Fetics, B., Nevo, E., Rochitte, C. E., Chiou, K.-R., Ding, P.-A., Kawaguchi, M., & Kass, D. A. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01651-5 · Cited by 654
Is the Failing Heart Energy Starved?: On Using Chemical Energy to Support Cardiac Function
Ingwall, J. S., & Weiss, R. G. (2004) · Circulation Research · doi:10.1161/01.res.0000137170.41939.d9 · Cited by 604
Cited by
Metabolic Mechanisms in Heart Failure
Ashrafian, H., Frenneaux, M. P., & Opie, L. H. (2007) · Circulation · doi:10.1161/circulationaha.107.702795 · Cited by 521
Diabetic cardiomyopathy: pathophysiology and clinical features
Miki, T., Yuda, S., Kouzu, H., & Miura, T. (2013) · Heart Failure Reviews · doi:10.1007/s10741-012-9313-3 · Cited by 460
Mustafa, S. J., Morrison, R. R., Teng, B., & Pelleg, A. (2009) · Handbook of Experimental Pharmacology · doi:10.1007/978-3-540-89615-9_6 · Cited by 251
“volume of blood ejected by the heart in a single day weighs over nine tons, and over one’s lifetime the volume of blood pumped by the heart could fill the Empire State Building! The energy required to perform work of this magnitude is almost exclusively derived from aerobic oxidation of various substrates in the form…”
BackgroundLemieux, H., Semsroth, S., Antretter, H., Höfer, D., & Gnaiger, E. (2011) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2011.08.008 · Cited by 179
Metadata
- Authors
- Knaapen, P., Germans, T., Knuuti, J., Paulus, W. J., Dijkmans, P. A., Allaart, C. P., Lammertsma, A. A., & Visser, F. C.
- Venue
- Circulation
- Published
- 2007-02-20
- Volume
- 115
- Issue
- 7
- Pages
- 918-927
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2112637952
- Cited by
- 199
- References
- 41
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Myocardial Energetics and Efficiency: Current Status of the Noninvasive Approach. https://app.cochat.ai/papers/10.1161/circulationaha.106.660639
- The paper
- Knaapen, P., Germans, T., Knuuti, J., Paulus, W. J., Dijkmans, P. A., Allaart, C. P., Lammertsma, A. A., & Visser, F. C. (2007). Myocardial Energetics and Efficiency: Current Status of the Noninvasive Approach. Circulation. https://doi.org/10.1161/circulationaha.106.660639
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.