The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Risk Factors Related to Infections of Implanted Pacemakers and Cardioverter-Defibrillators: Results of a Large Prospective Study
Abstract
Background— The Prospective Evaluation of Pacemaker Lead Endocarditis study is a multicenter, prospective survey of the incidence and risk factors of infectious complications after implantation of pacemakers and cardioverter-defibrillators. Methods and Results— Between January 1, 2000, and December 31, 2000, 6319 consecutive recipients of implantable systems were enrolled at 44 medical centers and followed up for 12 months. All infectious complications were recorded, and their occurrence was related to the baseline demographic, clinical, and procedural characteristics. Among 5866 pacing systems, 3789 included 2 and 117 had >2 leads; among 453 implantable cardioverter-defibrillators, 178 were dual-lead systems. A total of 4461 de novo implantations occurred and 1858 pulse generator or lead replacements. Reinterventions were performed before hospital discharge in 101 patients. Single- and multiple-variable logistic regression analyses were performed to identify risk factors; adjusted odds ratios (aORs) and 95% confidence intervals (CIs) were calculated. At 12 months, device-related infections were reported in 42 patients (0.68%; 95% CI, 0.47 to 0.89). The occurrence of infection was positively correlated with fever within 24 hours before the implantation procedure (aOR, 5.83; 95% CI, 2.00 to 16.98), use of temporary pacing before the implantation procedure (aOR, 2.46; 95% CI, 1.09 to 5.13), and early reinterventions (aOR, 15.04; 95% CI, 6.7 to 33.73). Implantation of a new system (aOR, 0.46; 95% CI, 0.24 to 0.87) and antibiotic prophylaxis (aOR, 0.4; 95% CI, 0.18 to 0.86) were negatively correlated with risk of infection. Conclusions— This study identified several factors of risk of device infection and confirmed the efficacy of antibiotic prophylaxis in recipients of new or replacement pacemakers or implantable cardioverter-defibrillators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Horan, T. C., Gaynes, R. P., Martone, W. J., Jarvis, W. R., & Grace Emori, T. (1992) · American Journal of Infection Control · doi:10.1016/s0196-6553(05)80201-9 · Cited by 2,609
Durack, D. T., Lukes, A. S., Bright, D. K., & Service, D. E. (1994) · The American Journal of Medicine · doi:10.1016/0002-9343(94)90143-0 · Cited by 2,572
Horan, T. C., Gaynes, R. P., Martone, W. J., Jarvis, W. R., & Emori, T. G. (1992) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700015241 · Cited by 1,396
Systemic Infection Related to Endocarditis on Pacemaker Leads: Clinical Presentation and Management
Klug, D., Lacroix, D., Savoye, C., Goullard, L., Grandmougin, D., Hennequin, J. L., Kacet, S., & Lekieffre, J. (1997) · Circulation · doi:10.1161/01.cir.95.8.2098 · Cited by 593
Self-citationDiagnosis and Management of Infections Involving Implantable Electrophysiologic Cardiac Devices
Chua, J. D., Wilkoff, B. L., Lee, I., Juratli, N., Longworth, D. L., & Gordon, S. M. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-8-200010170-00011 · Cited by 511
Rising Rates of Cardiac Rhythm Management Device Infections in the United States: 1996 through 2003
Voigt, A., Shalaby, A., & Saba, S. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.05.016 · Cited by 379
Antibiotic Prophylaxis for Permanent Pacemaker Implantation: A Meta-Analysis
Da Costa, A., Kirkorian, G., Cucherat, M., Delahaye, F., Chevalier, P., Cerisier, A., Isaaz, K., & Touboul, P. (1998) · Circulation · doi:10.1161/01.cir.97.18.1796 · Cited by 362
Aggarwal, R. K., Connelly, D. T., Ray, S. G., Ball, J., & Charles, R. G. (1995) · Heart · doi:10.1136/hrt.73.6.571 · Cited by 254
Early Complications After Dual Chamber Versus Single Chamber Pacemaker Implantation
CHAUHAN, A., GRACE, A. A., NEWELL, S. A., STONE, D. L., SHAPIRO, L. M., SCHOFIELD, P. M., & PETCH, M. C. (1994) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1994.tb03791.x · Cited by 217
Local symptoms at the site of pacemaker implantation indicate latent systemic infection
Klug, D., Wallet, F., Lacroix, D., Marquié, C., Kouakam, C., Kacet, S., & Courcol, R. (2004) · Heart · doi:10.1136/hrt.2003.010595 · Cited by 195
Self-citationLate complications following permanent pacemaker implantation or elective unit replacement
Harcombe, A. A., Newell, S. A., Ludman, P. F., Wistow, T. E., Sharples, L. D., Schofield, P. M., Stone, D. L., Shapiro, L. M., Cole, T., & Petch, M. C. (1998) · Heart · doi:10.1136/hrt.80.3.240 · Cited by 163
Nonvalvular Infections of the Cardiovascular System
Kearney, R. A., Eisen, H. J., & Wolf, J. E. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-121-3-199408010-00010 · Cited by 142
Hill, P. E. (1987) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1987.tb04521.x · Cited by 137
Bluhm, G. (1985) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1985.tb13940.x · Cited by 93
Ferguson, T. B., Ferguson, C., Crites, K., et al. (1996) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70334-3 · Cited by 79
Pacemaker Lead Infection in Young Patients
Klug, D., Vaksmann, G., Jarwe, M., WALLET, F., Francart, C., Kacet, S., & Rey, C. (2003) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2003.t01-1-00215.x · Cited by 78
Self-citationInfections with Nonthoracotomy Implantable Cardioverter Defibrillators: Can These Be Prevented?
Smith, P. N., Vidaillet, H. J., Jr., Hayes, J. J., WETHINGTON, P. J., VOSHAGE‐STAHL, L., HULL, M. L., & Broste, S. K. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01060.x · Cited by 71
Pacemaker lead infection: report of three cases and review of the literature
Voet, J. G., Vandekerckhove, Y. R., Muyldermans, L., Missault, L. H., & Matthys, L. J. (1999) · Heart · doi:10.1136/hrt.81.1.88 · Cited by 69
Actuarial Survival of Transvenous Pacing Leads in a Pediatric Population
Lau, Y. R., Gillette, P. C., Buckles, D. S., & Zeigler, V. L. (1993) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1993.tb01729.x · Cited by 52
Infected transvenous permanent pacemakers: Role of transesophageal echocardiography
Vilacosta, I., Zamorano, J., Camino, A., Román, J. A. S., Rollán, M. J., & Pinto, Á. G. (1993) · American Heart Journal · doi:10.1016/0002-8703(93)90194-e · Cited by 21
[Endocarditis on cardiac pacemaker endocavitary electrodes. Apropos of 7 cases].
Glock, Y., Sabatier, J., Salvador-Mazenq, M., & Puel, P. (1986) · PubMed · Cited by 14
Cited by
Tong, S. Y. C., Davis, J. S., Eichenberger, E., Holland, T. L., & Fowler, V. G. (2015) · Clinical Microbiology Reviews · doi:10.1128/cmr.00134-14 · Cited by 5,192
Habib, G., Lancellotti, P., Antunes, M. J., Bongiorni, M. G., Casalta, J.-P., Del Zotti, F., Dulgheru, R., El Khoury, G., Erba, P. A., Iung, B., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv319 · Cited by 4,997
Clinical practice guidelines for antimicrobial prophylaxis in surgery
Bratzler, D. W., Dellinger, E. P., Olsen, K. M., Perl, T. M., Auwaerter, P. G., Bolon, M. K., Fish, D. N., Napolitano, L. M., Sawyer, R. G., Slain, D., et al. (2013) · American Journal of Health-System Pharmacy · doi:10.2146/ajhp120568 · Cited by 2,591
Guidelines on the prevention, diagnosis, and treatment of infective endocarditis (new version 2009)
Endorsed by the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) and by the International Society of Chemotherapy (ISC) for Infection and Cancer, Habib, G., Hoen, B., Tornos, P., Thuny, F., Prendergast, B., Vilacosta, I., Moreillon, P., de Jesus Antunes, M., Thilen, U., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp285 · Cited by 2,014
2021 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy
Glikson, M., Nielsen, J. C., Kronborg, M. B., Michowitz, Y., Auricchio, A., Barbash, I. M., Barrabés, J. A., Boriani, G., Braunschweig, F., Brignole, M., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab364 · Cited by 2,019
Metadata
- Authors
- Klug, D., Balde, M., Pavin, D., Hidden-Lucet, F., Clementy, J., Sadoul, N., Rey, J. L., Lande, G., Lazarus, A., Victor, J., Barnay, C., Grandbastien, B., & Kacet, S.
- Venue
- Circulation
- Published
- 2007-09-18
- Volume
- 116
- Issue
- 12
- Pages
- 1349-1355
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2092968702
- Cited by
- 700
- References
- 21
- FWCI
- 19.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.