Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 357

The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.

Electropathological Substrate of Longstanding Persistent Atrial Fibrillation in Patients With Structural Heart Disease: Epicardial Breakthrough

Open access
de Groot, Natasja M.S., Houben, Richard P.M., Smeets, Joep L., Boersma, Eric, Schotten, Ulrich, Schalij, Martin J., Crijns, Harry, Allessie, Maurits A. · 2010 · Circulation

Abstract

Background—: During persistent atrial fibrillation (AF), waves with a focal spread of activation are frequently observed. The origin of these waves and their relevance for the persistence of AF are unknown. Methods and Results—: In 24 patients with longstanding persistent AF and structural heart disease, high-density mapping of the right and left atria was performed during cardiac surgery. In a reference group of 25 patients, AF was induced by rapid pacing. For data analysis, a mapping algorithm was developed that separated the fibrillatory process into its individual wavelets and identified waves with a focal origin. During persistent AF, the incidence of focal fibrillation waves in the right atrium was almost 4-fold higher than during acute AF (median, 0.46 versus 0.12 per cycle per 1 cm 2 (25th to 75th percentile, 0.40 to 0.77 and 0.01 to 0.27; P <0.0001). They were widely distributed over both atria and were recorded at 46±18 of all electrodes. A large majority (90.5) occurred as single events. Repetitive focal activity (>3) happened in only 0.8. The coupling interval was not more than 11 ms shorter than the average AF cycle length ( P =0.04), and they were not preceded by a long interval. Unipolar electrograms at the site of origin showed small but clear R waves. These data favor epicardial breakthrough rather than a cellular focal mechanism as the underlying mechanism. Often, conduction from a site of epicardial breakthrough was blocked in 1 or more directions. This generated separate multiple wave fronts propagating in different directions over the epicardium. Conclusions—: Focal fibrillation waves are due to epicardial breakthrough of waves propagating in deeper layers of the atrial wall. In patients with longstanding AF, the frequency of epicardial breakthroughs was 4 times higher than during acute AF. Because they provide a constant source of independent fibrillation waves originating over the entire epicardial surface, they offer an adequate explanation for the high persistence of AF in patients with structural heart disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.109.910901

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 357

Metadata

Authors
de Groot, N. M. S., Houben, R. P. M., Smeets, J. L., Boersma, E., Schotten, U., Schalij, M. J., Crijns, H., & Allessie, M. A.
Venue
Circulation
Published
2010-10-26
Volume
122
Issue
17
Pages
1674-1682
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2073774934
Cited by
357
References
34
FWCI
11.45
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.