The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Stent Thrombogenicity Early in High-Risk Interventional Settings Is Driven by Stent Design and Deployment and Protected by Polymer-Drug Coatings
Open accessAbstract
Background—: Stent thrombosis is a lethal complication of endovascular intervention. Concern has been raised about the inherent risk associated with specific stent designs and drug-eluting coatings, yet clinical and animal support is equivocal. Methods and Results—: We examined whether drug-eluting coatings are inherently thrombogenic and if the response to these materials was determined to a greater degree by stent design and deployment with custom-built stents. Drug/polymer coatings uniformly reduce rather than increase thrombogenicity relative to matched bare metal counterparts (0.65-fold; P =0.011). Thick-strutted (162 μm) stents were 1.5-fold more thrombogenic than otherwise identical thin-strutted (81 μm) devices in ex vivo flow loops ( P <0.001), commensurate with 1.6-fold greater thrombus coverage 3 days after implantation in porcine coronary arteries ( P =0.004). When bare metal stents were deployed in malapposed or overlapping configurations, thrombogenicity increased compared with apposed, length-matched controls (1.58-fold, P =0.001; and 2.32-fold, P <0.001). The thrombogenicity of polymer-coated stents with thin struts was lowest in all configurations and remained insensitive to incomplete deployment. Computational modeling–based predictions of stent-induced flow derangements correlated with spatial distribution of formed clots. Conclusions—: Contrary to popular perception, drug/polymer coatings do not inherently increase acute stent clotting; they reduce thrombosis. However, strut dimensions and positioning relative to the vessel wall are critical factors in modulating stent thrombogenicity. Optimal stent geometries and surfaces, as demonstrated with thin stent struts, help reduce the potential for thrombosis despite complex stent configurations and variability in deployment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iakovou, I. (2005) · JAMA · doi:10.1001/jama.293.17.2126 · Cited by 3,132
On the mechanisms of biocompatibility
Williams, D. F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.023 · Cited by 2,772
Kastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schühlen, H., Neumann, F.-J., Fleckenstein, M., Pfafferott, C., Seyfarth, M., & Schömig, A. (2001) · Circulation · doi:10.1161/01.cir.103.23.2816 · Cited by 938
Everolimus-Eluting versus Paclitaxel-Eluting Stents in Coronary Artery Disease
Stone, G. W., Rizvi, A., Newman, W., Mastali, K., Wang, J. C., Caputo, R., Doostzadeh, J., Cao, S., Simonton, C. A., Sudhir, K., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0910496 · Cited by 902
Incomplete Stent Apposition and Very Late Stent Thrombosis After Drug-Eluting Stent Implantation
Cook, S., Wenaweser, P., Togni, M., Billinger, M., Morger, C., Seiler, C., Vogel, R., Hess, O., Meier, B., & Windecker, S. (2007) · Circulation · doi:10.1161/circulationaha.106.658237 · Cited by 839
Biondi-Zoccai, G. G. L., Lotrionte, M., Agostoni, P., Abbate, A., Fusaro, M., Burzotta, F., Testa, L., Sheiban, I., & Sangiorgi, G. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl334 · Cited by 733
Kedhi, E., Joesoef, K. S., McFadden, E., Wassing, J., van Mieghem, C., Goedhart, D., & Smits, P. C. (2010) · The Lancet · doi:10.1016/s0140-6736(09)62127-9 · Cited by 687
Nakazawa, G., Finn, A. V., Joner, M., Ladich, E., Kutys, R., Mont, E. K., Gold, H. K., Burke, A. P., Kolodgie, F. D., & Virmani, R. (2008) · Circulation · doi:10.1161/circulationaha.107.762047 · Cited by 611
Pache, J. Ü., Kastrati, A., Mehilli, J., Schühlen, H., Dotzer, F., Hausleiter, J. Ö., Fleckenstein, M., Neumann, F.-J., Sattelberger, U., Schmitt, C., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00119-0 · Cited by 557
Endovascular Stent Design Dictates Experimental Restenosis and Thrombosis
Rogers, C., & Edelman, E. R. (1995) · Circulation · doi:10.1161/01.cir.91.12.2995 · Cited by 543
Self-citationContact activation of blood-plasma coagulation
Vogler, E. A., & Siedlecki, C. A. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.041 · Cited by 299
Hassan, A. K. M., Bergheanu, S. C., Stijnen, T., van der Hoeven, B. L., Snoep, J. D., Plevier, J. W. M., Schalij, M. J., & Wouter Jukema, J. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehn553 · Cited by 290
In Vitro Analyses of Diamond-like Carbon Coated Stents
Gutensohn, K., Beythien, C., Bau, J., Fenner, T., Grewe, P., Koester, R., Padmanaban, K., & Kuehnl, P. (2000) · Thrombosis Research · doi:10.1016/s0049-3848(00)00295-4 · Cited by 279
A Comparison of Bare-Metal and Drug-Eluting Stents for Off-Label Indications
Marroquin, O. C., Selzer, F., Mulukutla, S. R., Williams, D. O., Vlachos, H. A., Wilensky, R. L., Tanguay, J.-F., Holper, E. M., Abbott, J. D., Lee, J. S., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0706258 · Cited by 270
Meta-analysis of femoropopliteal bypass grafts for lower extremity arterial insufficiency
Pereira, C. E., Albers, M., Romiti, M., Brochado-Neto, F. C., & Pereira, C. A. B. (2006) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2006.04.054 · Cited by 245
Long-Term Safety and Efficacy of Drug-Eluting versus Bare-Metal Stents in Sweden
James, S. K., Stenestrand, U., Lindbäck, J., Carlsson, J., Scherstén, F., Nilsson, T., Wallentin, L., & Lagerqvist, B. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0809902 · Cited by 237
Late Coronary Stent Thrombosis
Windecker, S., & Meier, B. (2007) · Circulation · doi:10.1161/circulationaha.106.683995 · Cited by 226
Rasmussen, K., Maeng, M., Kaltoft, A., Thayssen, P., Kelbæk, H., Tilsted, H. H., Abildgaard, U., Christiansen, E. H., Engstrøm, T., Krusell, L. R., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60208-5 · Cited by 212
Angiolillo, D. J., Fernandez-Ortiz, A., Bernardo, E., Ramírez, C., Sabaté, M., Jimenez-Quevedo, P., Hernández, R., Moreno, R., Escaned, J., Alfonso, F., et al. (2006) · Diabetes · doi:10.2337/diabetes.55.03.06.db05-1394 · Cited by 158
Novel thromboresistant materials
Jordan, S. W., & Chaikof, E. L. (2007) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2007.02.048 · Cited by 153
Ellis, S. G., Colombo, A., Grube, E., Popma, J. J., Koglin, J., Dawkins, K. D., & Stone, G. W. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.01.015 · Cited by 128
Byrne, R. A., Kastrati, A., Tiroch, K. A., Schulz, S., Pache, J., Pinieck, S., Maßberg, S., Seyfarth, M., Laugwitz, K., Birkmeier, K. A., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.03.020 · Cited by 115
Ruygrok, P., & Serruys, P. W. J. C. (1996) · Circulation · doi:10.1161/01.cir.94.5.882 · Cited by 69
Sawyer, P. N., & Srinivasan, S. (1972) · PubMed · Cited by 61
Luminal Flow Amplifies Stent-Based Drug Deposition in Arterial Bifurcations
Kolachalama, V. B., Levine, E. G., & Edelman, E. R. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008105 · Cited by 61
Self-citationChan, M. Y., Weitz, J. I., Merhi, Y., Harrington, R. A., & Becker, R. C. (2009) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-009-0375-6 · Cited by 25
Cited by
Palmerini, T., Biondi-Zoccai, G., Riva, D. D., Stettler, C., Sangiorgi, D., D'Ascenzo, F., Kimura, T., Briguori, C., Sabatè, M., Kim, H.-S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60324-9 · Cited by 959
Drug-Eluting Coronary-Artery Stents
Stefanini, G. G., & Holmes, D. R. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1210816 · Cited by 728
Byrne, R. A., Joner, M., & Kastrati, A. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv511 · Cited by 609
Otsuka, F., Vorpahl, M., Nakano, M., Foerst, J., Newell, J. B., Sakakura, K., Kutys, R., Ladich, E., Finn, A. V., Kolodgie, F. D., et al. (2014) · Circulation · doi:10.1161/circulationaha.113.001790 · Cited by 491
Long-Term Safety of Drug-Eluting and Bare-Metal Stents
Palmerini, T., Benedetto, U., Biondi-Zoccai, G., Della Riva, D., Bacchi-Reggiani, L., Smits, P. C., Vlachojannis, G. J., Jensen, L. O., Christiansen, E. H., Berencsi, K., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.04.017 · Cited by 470
Metadata
- Authors
- Kolandaivelu, K., Swaminathan, R., Gibson, W. J., Kolachalama, V. B., Nguyen-Ehrenreich, K.-L., Giddings, V. L., Coleman, L., Wong, G. K., & Edelman, E. R.
- Venue
- Circulation
- Published
- 2011-04-05
- Volume
- 123
- Issue
- 13
- Pages
- 1400-1409
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W1595078900
- Cited by
- 802
- References
- 26
- FWCI
- 46.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.