The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Optical Coherence Tomographic Analysis of In-Stent Neoatherosclerosis After Drug–Eluting Stent Implantation
Open accessAbstract
Background—: We report findings from optical coherence tomography (OCT) of in-stent neoatherosclerosis as a cause of drug-eluting stent (DES) failure. Methods and Results—: Optical coherence tomography and grayscale and virtual histology intravascular ultrasound were performed in 50 patients (30 stable, 20 unstable angina) with 50 DES in-stent restenosis lesions and intimal hyperplasia >50% of stent area. Median follow-up time was 32.2 months. Overall, 26 lesions (52%) had at least 1 OCT-defined in-stent thin-cap fibroatheroma (TCFA)–containing neointima and 29 (58%) had at least 1 in-stent neointimal rupture. Patients presenting with unstable angina showed a thinner fibrous cap (55 μm [interquartile range 42 to 105 μm] versus 100 μm [interquartile range 60 to 205 μm], P =0.006) and higher incidence of OCT-defined TCFA-containing neointima (75% versus 37%, P =0.008), intimal rupture (75% versus 47%, P =0.044), thrombi (80% versus 43%, P =0.010), and red thrombi (30% versus 3%, P =0.012) than stable patients. Fibrous cap thickness negatively correlated with follow-up time ( r =−0.318, P =0.024). Compared with DES <20 months after implantation (the best cut-off to predict TCFA-containing neointima), DES ≥20 months after implantation had a higher incidence of TCFA-containing neointima (69% versus 33%, P =0.012) and red thrombi (27% versus 0%, P =0.007). Patients with unstable (versus stable) angina had an increasing number of unstable OCT findings including TCFA-containing neointima, neointima rupture, and thrombus ( P =0.027). The rate of agreement between grayscale intravascular ultrasound and OCT for detecting intimal rupture was 50% and for detecting thrombus was 44%. The agreement between virtual histology intravascular ultrasound and OCT for identifying TCFA-containing neointima was 78%. Conclusions—: In-stent neoatherosclerosis may be an important mechanism of DES failure, especially late after implantation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ryan, T. J., Faxon, D. P., Gunnar, R. M., Kennedy, J. W., King, S. B., Loop, F. D., Peterson, K. L., Reeves, T. J., Williams, D. O., & Winters, W. L. (1988) · Circulation · doi:10.1161/01.cir.78.2.486 · Cited by 2,123
Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis
Stettler, C., Wandel, S., Allemann, S., Kastrati, A., Morice, M. C., Schömig, A., Pfisterer, M. E., Stone, G. W., Leon, M. B., de Lezo, J. S., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61444-5 · Cited by 1,428
Self-citationAngiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Self-citationCharacterization of Human Atherosclerosis by Optical Coherence Tomography
Yabushita, H., Bouma, B. E., Houser, S. L., Aretz, H. T., Jang, I.-K., Schlendorf, K. H., Kauffman, C. R., Shishkov, M., Kang, D.-H., Halpern, E. F., et al. (2002) · Circulation · doi:10.1161/01.cir.0000029927.92825.f6 · Cited by 1,246
Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data Analysis
Nair, A., Kuban, B. D., Tuzcu, E. M., Schoenhagen, P., Nissen, S. E., & Vince, D. G. (2002) · Circulation · doi:10.1161/01.cir.0000035654.18341.5e · Cited by 1,193
Vascular Responses to Drug Eluting Stents: Importance of Delayed Healing
Finn, A. V., Nakazawa, G., Joner, M., Kolodgie, F. D., Mont, E. K., Gold, H. K., & Virmani, R. (2007) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.107.144220 · Cited by 900
In Vivo Characterization of Coronary Atherosclerotic Plaque by Use of Optical Coherence Tomography
Jang, I.-K., Tearney, G. J., MacNeill, B., Takano, M., Moselewski, F., Iftima, N., Shishkov, M., Houser, S., Aretz, H. T., Halpern, E. F., et al. (2005) · Circulation · doi:10.1161/01.cir.0000159354.43778.69 · Cited by 896
Prati, F., Regar, E., Mintz, G. S., Arbustini, E., Di Mario, C., Jang, I.-K., Akasaka, T., Costa, M., Guagliumi, G., Grube, E., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehp433 · Cited by 880
Self-citationAssessment of Culprit Lesion Morphology in Acute Myocardial Infarction
Kubo, T., Imanishi, T., Takarada, S., Kuroi, A., Ueno, S., Yamano, T., Tanimoto, T., Matsuo, Y., Masho, T., Kitabata, H., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.082 · Cited by 867
Self-citationAssessment of Coronary Arterial Plaque by Optical Coherence Tomography
Kume, T., Akasaka, T., Kawamoto, T., Watanabe, N., Toyota, E., Neishi, Y., Sukmawan, R., Sadahira, Y., & Yoshida, K. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.035 · Cited by 573
Self-citationThree-Year Follow-up after Implantation of Metallic Coronary-Artery Stents
Kimura, T., Yokoi, H., Nakagawa, Y., Tamura, T., Kaburagi, S., Sawada, Y., Sato, Y., Yokoi, H., Hamasaki, N., Nosaka, H., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340903 · Cited by 507
A Paclitaxel-Eluting Stent for the Prevention of Coronary Restenosis
Park, S.-J., Shim, W. H., Ho, D. S., Raizner, A. E., Park, S.-W., Hong, M.-K., Lee, C. W., Choi, D., Jang, Y., Lam, R., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021007 · Cited by 456
Self-citationBare metal stent restenosis is not a benign clinical entity
Chen, M. S., John, J. M., Chew, D. P., Lee, D. S., Ellis, S. G., & Bhatt, D. L. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.08.011 · Cited by 413
Rodriguez-Granillo, G. A., García-García, H. M., Mc Fadden, E. P., Valgimigli, M., Aoki, J., de Feyter, P., & Serruys, P. W. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.064 · Cited by 392
Thim, T., Hagensen, M. K., Wallace-Bradley, D., Granada, J. F., Kaluza, G. L., Drouet, L., Paaske, W. P., Bøtker, H. E., & Falk, E. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.919357 · Cited by 217
One Step Forward and Two Steps Back With Drug-Eluting-Stents
Nakazawa, G., Vorpahl, M., Finn, A. V., Narula, J., & Virmani, R. (2009) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2009.01.011 · Cited by 175
Lee, S., Park, S., Kim, Y., Yun, S., Park, D., Lee, C. W., Hong, M., Rhee, K., Chae, J. K., Ko, J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.04.056 · Cited by 87
Self-citation
Cited by
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
(2014) · European Heart Journal · doi:10.1093/eurheartj/ehu278 · Cited by 4,314
2014 ESC/EACTS Guidelines on myocardial revascularization
Kolh, P., Windecker, S., Alfonso, F., Collet, J.-P., Cremer, J., Falk, V., Filippatos, G., Hamm, C., Head, S. J., Jüni, P., et al. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu366 · Cited by 4,199
2018 ESC/EACTS Guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · EuroIntervention · doi:10.4244/eijy19m01_01 · Cited by 1,259
2018 ESC/EACTS Guidelines on myocardial revascularization
Sousa-Uva, M., Neumann, F.-J., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezy289 · Cited by 989
Metadata
- Authors
- Kang, S.-J., Mintz, G. S., Akasaka, T., Park, D.-W., Lee, J.-Y., Kim, W.-J., Lee, S.-W., Kim, Y.-H., Whan Lee, C., Park, S.-W., & Park, S.-J.
- Venue
- Circulation
- Published
- 2011-06-28
- Volume
- 123
- Issue
- 25
- Pages
- 2954-2963
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2020417508
- Cited by
- 359
- References
- 17
- FWCI
- 39.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.