Mechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Abstract
Background Because of its episodic behavior, the correlation of spontaneous syncope with an abnormal finding can be considered a reference standard. Methods and Results We inserted an implantable loop recorder in 111 patients with syncope, absence of significant structural heart disease, and a normal ECG; tilt-testing was negative in 82 (isolated syncope) and positive in 29 (tilt-positive). The patients had had ≥3 episodes of syncope in the previous 2 years and were followed up for 3 to 15 months. Results were similar in the isolated syncope group and the tilt-positive group: syncope recurred in 28 (34%) and 10 patients (34%), respectively, and electrocardiographic correlation was found in 24 (23%) and 8 (28%) patients, respectively. The most frequent finding, which was recorded in 46% and 62% of patients, respectively, was one or more prolonged asystolic pauses, mainly due to sinus arrest, preceded for a few minutes by progressive bradycardia or progressive tachycardia-bradycardia. Bradycardia without pauses was observed in 8% and 12% of cases, respectively. The remaining patients had normal sinus rhythm or sinus tachycardia, except for one, who had ectopic atrial tachycardia. In the tilt-positive group, an asystolic syncope was also recorded when the type of response to tilt-testing was vasodepressor or mixed. Presyncopal episodes were never characterized by asystolic pauses; normal sinus rhythm was the most frequent finding. Conclusions Homogeneous findings were observed during syncope. In most patients, the likely cause was neurally-mediated, and the most frequent mechanism was a bradycardic reflex. In the other cases, a normal sinus rhythm was frequently recorded. Presyncope was not an accurate surrogate for syncope in establishing a diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These patients appear to benefit from permanent pacing.105–112”
From 2015 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Treatment of Postural Tachycardia Syndrome, Inappropriate Sinus Tachycardia, and Vasovagal Syncope (2015) · cites this paper as [107]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, the devices have been shown to improve care in only the subset of patients who are older, have asystole documented on the ILR, and whose tilt test results were negative, probably because many of the diagnoses are of vasovagal syncope.”
From 2015 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Treatment of Postural Tachycardia Syndrome, Inappropriate Sinus Tachycardia, and Vasovagal Syncope (2015) · cites this paper as [107]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sutton, R., Brignole, M., Menozzi, C., Raviele, A., Alboni, P., Giani, P., & Moya, A. (2000) · Circulation · doi:10.1161/01.cir.102.3.294 · Cited by 407
Self-citationUse of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360 · cited 11×
“Participating Centers and Investigators (number of patients in brackets) Ospedale S. Maria Nuova, Reggio Emilia: C. Menozzi, N. Bottoni (21); Ospedale Villa Maria, Piombino: S. Tognarini, S. Bechi (8); Hospital Clinico, Barcelona: L. Mont (7); Ospedali Riuniti, Lavagna: M. Brignole, P. Donateo, G. Gaggioli (6); Ospeda…”
BackgroundInfluentialRaviele, A., Menozzi, C., Brignole, M., Gasparini, G., Alboni, P., Musso, G., Lolli, G., Oddone, D., Dinelli, M., & Mureddu, R. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80079-4 · Cited by 249
Self-citationRisk Factors for Syncope Recurrence After a Positive Tilt-Table Test in Patients With Syncope
Sheldon, R. S., Rose, S., Flanagan, P., Koshman, M. L., & Killam, S. (1996) · Circulation · doi:10.1161/01.cir.93.5.973 · Cited by 231
The etiology of syncope in patients with negative tilt table and electrophysiological testing
Krahn, A. D., Klein, G. J., Norris, C., & Yee, R. (1995) · Circulation · doi:10.1161/01.cir.92.7.1819 · Cited by 215
Raviele, A., Brignole, M., Sutton, R., Alboni, P., Giani, P., Menozzi, C., & Moya, A. (1999) · Circulation · doi:10.1161/01.cir.99.11.1452 · Cited by 201
Self-citationLeitch, J. W., Klein, G. J., Yee, R., Leather, R. A., & Kim, Y. H. (1992) · Circulation · doi:10.1161/01.cir.85.3.1064 · Cited by 171
Diagnostic accuracy of a low-dose isoproterenol head-up tilt protocol
Morillo, C. A., Klein, G. J., Zandri, S., & Yee, R. K. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90110-8 · Cited by 155
Diagnostic and prognostic implicatioins of recurrences in patients with syncope
Kapoor, W. N., Peterson, J., Wieand, H. S., & Karpf, M. (1987) · The American Journal of Medicine · doi:10.1016/0002-9343(87)90901-6 · Cited by 126
Heart Rhythm During Syncope and Presyncope: Results of Implantable Loop Recorders
Nierop, P. R., van Mechelen, R., ELSÄCKER, A. V., LUIJTEN, R. H. M., & Elhendy, A. A. (2000) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2000.01532.x · Cited by 86
Flagged first, then by citations
Research works printed but not linked: 7
- 10.1161/circ.99.3.406 · DOI
- 10.1161/circ.93.5.973 · DOI
- 10.1161/circ.102.3.294 · DOI
- 10.1161/circ.99.11.1452 · DOI
- 10.1161/circ.85.3.1537103 · DOI
- 10.1161/circ.92.7.1819 · DOI
- Alboni P, Dinelli M, Raviele A, et al. Is a second tilt test useful in patients with unexplained syncope? Eur J Cardiac Pacing Electrophysiol. 1995; 5: 292–295.
Cited by
Sorted by citations
Items 201–300 of 375
Neurocardiogenic Syncope during a Routine Colonoscopy: An Uncommon Malignant Presentation
Sharma, G., Senguttuvan, N. B., Juneja, R., & Bahl, V. K. (2012) · Internal Medicine · doi:10.2169/internalmedicine.51.6622 · Cited by 6
Implantable Loop Recorders for Cardiac Dysrhythmia Monitoring
Akella, K., Murtaza, G., Rocca, D. G. D., Kodwani, N., Gopinathannair, R., Natale, A., & Lakkireddy, D. (2020) · Future Cardiology · doi:10.2217/fca-2020-0035 · Cited by 7
Use of Implantable Loop Recorders to Unravel the Cause of Unexplained Syncope
Puri, A., & Srivastava, R. K. (2013) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30606-4 · Cited by 6
Contemporary Yield of 24-hour Holter Monitoring: Role of Inter-Atrial Block Recognition
Bazán, V., Cediel, G., Cinta, L., Sarrias, A., Isabel, R., Sònia, I., Francisco, E. A., Moré, S. V., Bisbal, F., Villuendas, R., et al. (2019) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2225 · Cited by 6
Angaran, P., Klein, G. J., Yee, R. K., Skanes, A. C., Gula, L. J., Leong‐Sit, P., & Krahn, A. D. (2011) · Neurologic Clinics · doi:10.1016/j.ncl.2011.07.005 · Cited by 6
Raj, S. R., & Robertson, R. M. (2004) · Elsevier eBooks · doi:10.1016/b978-012589762-4/50067-0 · Cited by 6
Sutton, R. (2012) · Heart · doi:10.1136/heartjnl-2012-303062 · Cited by 6
Babaei, M., Tajdini, M., Bozorgi, A., Sadeghian, S., Taebi, M., Tavolinejad, H., Mahalleh, M., Taheri, H., Rader, F., Boris, J. R., et al. (2025) · European Heart Journal Open · doi:10.1093/ehjopen/oeaf061 · Cited by 5
Pentimalli, F., Bacino, L., Ghione, M., Siri, G., Gazzarata, M., & Bellotti, P. (2016) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1421 · Cited by 5
Does any therapy really work for neurocardiogenic syncope?
Hawkins, N. M., & Krahn, A. D. (2014) · Cardiology Journal · doi:10.5603/cj.2014.0094 · Cited by 5
The future of cardioneuroablation in cardiovascular medicine
Aksu, T., Khan, A., & Huang, H. D. (2022) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2022.2147926 · Cited by 5
GREGORIO, C. D., Lentini, C., Grimaldi, P., Zagari, D., Andò, G., Bella, G. D., & Coglitore, S. (2014) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2014.03.007 · Cited by 5
Experience With Implantable Loop Recorders for Recurrent Unexplained Syncope
Brignole, M. (2008) · Congestive Heart Failure · doi:10.1111/j.1751-7133.2008.tb00014.x · Cited by 4
Self-citationSyncope: An Evidence-Based Approach
Iwai, S. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4441-0_40 · Cited by 5
Futterman, L. G., & Lemberg, L. (2002) · The Journal of Cardiovascular Nursing · doi:10.1097/00005082-200204000-00004 · Cited by 5
Brignole, M. (2005) · doi:10.1002/9780470994801.ch7 · Cited by 5
Self-citationExplaining the Unexplained Causes of Syncope
Mehta, N., Távora, M. Z. P., & Morillo, C. A. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.01.039 · Cited by 5
Cardiac pacing in patients with familial dysautonomia
Bartoletti, A. (2005) · Clinical Autonomic Research · doi:10.1007/s10286-005-0242-2 · Cited by 5
Salih, H., Monsel, F., Sergent, J., & Amara, W. (2012) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2012.08.033 · Cited by 4
Orthostatic Challenge Tests: Active Standing and Head-Up Tilt
Nordkamp, L. R. A. O., van Dijk, N., & Wieling, W. (2013) · Springer eBooks · doi:10.1007/978-1-4471-4978-1_12 · Cited by 4
Raj, S. R., & Sheldon, R. S. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00073-9 · Cited by 4
Steinberg, C., Bennett, M. T., & Krahn, A. D. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_5 · Cited by 5
Exercise-related syncope: are athletes different from sedentary subjects?
Brignole, M. (2002) · European Heart Journal · doi:10.1053/euhj.2001.3123 · Cited by 4
Self-citationRole of permanent cardiac pacing for vasovagal syncope
Sumiyoshi, M. (2014) · Journal of Arrhythmia · doi:10.1016/j.joa.2014.04.009 · Cited by 4
The hidden part of neurally mediated disease
Brignole, M. (2002) · EP Europace · doi:10.1053/eupc.2002.0247 · Cited by 4
Self-citationMoya‐Mitjans, À. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.015 · Cited by 4
Holding Area LINQ Trial (HALT)
Lee, J. J., Weitz, D. S., & Anand, R. G. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.06.003 · Cited by 4
Adlakha, H., Gupta, R., Hassan, R., & Kern, J. H. (2018) · Cureus · doi:10.7759/cureus.2119 · Cited by 4
Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Nazzari, H., Halperin, L. F., & Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809657-4.99770-9 · Cited by 3
A contemporary review of the head-up tilt test: Utility and limitations
Udyavar, A. R., Shenthar, J., Naik, A. M., Khanra, D., Ramalingam, V., Singhal, R., Choudhary, D., Gupta, P. N., Rao, B. H., Mehrotra, S., et al. (2025) · Indian Heart Journal · doi:10.1016/j.ihj.2025.03.014 · Cited by 9
El síncope: un problema con mayúsculas
Moya‐Mitjans, À., Rivas‐Gándara, N., Pérez‐Rodon, J., Roca, I., & García‐Dorado, D. (2010) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(10)70112-6 · Cited by 3
Wijesekera, N. T., & Kurbaan, A. S. (2002) · PubMed · Cited by 3
Swale, M., Paul, V., Delacroix, S., Young, G. D., McSpadden, L. C., Ryu, K., Fiore, D. D., Santos, M., Tan, I., Conradie, A., et al. (2022) · BMC Cardiovascular Disorders · doi:10.1186/s12872-022-02752-0 · Cited by 3
Overview of the Contribution of Recent Clinical Trials to Advancement of Syncope Management
Moya‐Mitjans, À., Rivas‐Gándara, N., & Pérez‐Rodon, J. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2012.11.007 · Cited by 3
Vom Bewusstseinsverlust zur Synkope
Ebert, H., Walter, C., & Volkmann, H. (2011) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-011-0127-0 · Cited by 3
Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R. K., & Krahn, A. D. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_23 · Cited by 3
Recurrent Syncope Triggered by Inappropriate Sinus Tachycardia
Mönnig, G., Ribbing, M., Wasmer, K., BREITHARDT, G. E., & Eckardt, L. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00629.x · Cited by 3
Estimulación cardiaca en situaciones diversas
Andrés, M. L. F., Pérez, J. T., Álvarez, L. P., Nicolás, J. R., Ferrer, J. M., & Montiel, J. D. J. (2007) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(07)75263-9 · Cited by 3
The role of the implantable loop recorder in the investigation of recurrent syncope.
Sideris, S. K., Mousiama, T. A., Stougiannos, P. N., Skiadas, I., Laiou, F. P., Sotiropoulos, I., Gatzoulis, K. A., Stefanadis, C., & Kallikazaros, I. E. (2009) · PubMed · Cited by 3
Cardiac arrest during recovery after tilt-induced vasodepressor syncope in a 76-year old man
Zyśko, D., Fedorowski, A., & Sutton, R. (2016) · Journal of Acute Medicine · doi:10.1016/j.jacme.2016.05.002 · Cited by 3
Benditt, D. G., Adkisson, W. O., & Sutton, R. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00066-2 · Cited by 3
Vasovagal syncope with asystole during repeated emesis in the emergency department
McCabe, Z., Schwartz, A. B., & Shetty, S. (2021) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2021.01.002 · Cited by 3
Ray, J. C., Kusumoto, F. M., & Goldschlager, N. (2014) · Journal of Intensive Care Medicine · doi:10.1177/0885066614552988 · Cited by 3
La prueba en tabla basculante en el síncope vasovagal: ¿para qué?, ¿a quién?
Moya‐Mitjans, À. (2002) · Revista Española de Cardiología · doi:10.1016/s0300-8932(02)76636-0 · Cited by 3
Is the Prognostic Significance of Presyncope the Same as for Syncope?
Peinado, R. (2004) · Revista Española de Cardiología (English Edition) · doi:10.1016/s1885-5857(06)60284-3 · Cited by 3
Presíncope: ¿un síntoma con igual significado pronóstico que el síncope?
Peinado, R. (2004) · Revista Española de Cardiología · doi:10.1016/s0300-8932(04)77161-4 · Cited by 3
Indikationen Zur Loop-Rekorder-Implantation Bei Synkope
Schuchert, A. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0571-1 · Cited by 2
Cocchiara, L., Brescia, B., Marchese, P., Nardi, S., Arabia, G., Salucci, A., Gennaro, F., Mazzotta, G., Addeo, L., Calvi, E., et al. (2025) · Heart · doi:10.1136/heartjnl-2025-326430 · Cited by 2
Mechanical Aspects of Cardiac Performance
Loushin, M. K., Quill, J. L., & Iaizzo, P. A. (2009) · Humana Press eBooks · doi:10.1007/978-1-60327-372-5_18 · Cited by 2
Vidya, P. L., Ananthakrishnan, R., Mukherjee, R., Sharma, P., Joshi, S., & Mohanty, S. (2021) · Medical Journal Armed Forces India · doi:10.1016/j.mjafi.2020.12.016 · Cited by 1
Russo, V., Comune, A., Parente, E., Rago, A., Papa, A. A., Nigro, G., & Brignole, M. (2024) · Clinical Autonomic Research · doi:10.1007/s10286-024-01021-8 · Cited by 2
Self-citationAmara, W., Sileu, N., Salih, H., Sergent, J., & Monsel, F. (2014) · Annales de Cardiologie et d Angéiologie · doi:10.1016/j.ancard.2014.08.007 · Cited by 2
The Benefit of Implantable Loop Recorders in the Diagnosis of Recurrent Syncope
Thanavaro, J. L., & Thanavaro, S. (2009) · The Journal for Nurse Practitioners · doi:10.1016/j.nurpra.2009.03.018 · Cited by 2
Kanjwal, M. Y., & Grubb, B. P. (2005) · Current Cardiology Reports · doi:10.1007/s11886-005-0085-4 · Cited by 2
Is There Any Room for Adenosine Test in Syncope of Unknown Origin
Albina, G., Scazzuso, F., Sammartino, V., Rivera, S., Laiño, R. A., & Giniger, A. (2011) · Dialnet (Universidad de la Rioja) · doi:10.7775/rac.79.1.522 · Cited by 2
Певзнер, А. В., Kuchinskaya, Е. А., Киктев, В. Г., & Хеймец, Г. И. (2021) · Rational Pharmacotherapy in Cardiology · doi:10.20996/1819-6446-2021-04-09 · Cited by 2
Ahn, Y., & Cho, J. G. (2003) · Heart · doi:10.1136/heart.90.1.58 · Cited by 2
Mansourati, J. (2005) · EMC - Cardiologie · doi:10.1016/s1166-4568(05)31241-1 · Cited by 2
Syncope: an overview of diagnosis and treatment
Benditt, D. G. (2011) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 2
Kajdič, N., Mežnar, A. Z., Šinkovec, M., & Žižek, D. (2020) · Minerva Cardiology and Angiology · doi:10.23736/s0026-4725.20.05247-0 · Cited by 3
Benditt, D. G., & Sutton, R. (2005) · Wiley eBooks · doi:10.1002/9780470994801.ch4 · Cited by 2
Upgrading from ventricular to physiological pacing: is it worth it?
Daubert, C. (2002) · European Heart Journal · doi:10.1053/euhj.2001.2991 · Cited by 2
Automatic control of mean arterial pressure based on a baroreflex-feedback cardiovascular model
Carbó, R., Rodríguez, E., & Alvarez-Ramirez, J. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108036 · Cited by 1
Happ, S., Raj, S. R., Chew, D. S., & Sheldon, R. S. (2026) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.70155 · Cited by 1
Implantable Loop Recorder in Clinical Practice
Babuty, D., Pierre, B., Clémenty, N., Lallemand, B., Marie, O., & Fauchier, L. (2011) · InTech eBooks · doi:10.5772/21350 · Cited by 1
Síncope: revisión diagnóstica y terapéutica
Benditt, D. G. (2011) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 1
Can we diagnose, treat or even understand neurally mediated syncope?
Raj, S. R., Diedrich, A., & Biaggioni, I. (2005) · Clinical Science · doi:10.1042/cs20050122 · Cited by 1
Síncope reflexa vasovagal – haverá benefício da terapêutica com pacemaker?
Sousa, P. A., Candeias, R., Marques, N. S., & de Jesus, I. (2014) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2014.02.007 · Cited by 1
What Can We Expect from the ISSUE 3 Trial?
Sutton, R., & Brignole, M. (2011) · Journal of Arrhythmia · doi:10.1016/s1880-4276(11)80018-9 · Cited by 1
Self-citationReflex vasovagal syncope – Is there a benefit in pacemaker therapy?
Sousa, P. A., Candeias, R., Marques, N. S., & de Jesus, I. (2014) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2014.05.001 · Cited by 1
A profound case of neurally mediated syncope with asystole after septoplasty
Ruhl, D. S., Ramsey, M. J., & Ruffin, D. M. (2012) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2011.10.006 · Cited by 1
The Value of Tilt Testing and Autonomic Nervous System Assessment
Sutton, R. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.003 · Cited by 1
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.009 · Cited by 1
Self-citationMoya‐Mitjans, À. (2013) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2013.08.015 · Cited by 1
Fisher, J. D. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9579-8 · Cited by 1
Sutton, R. (2013) · Journal of Medical Diagnostic Methods · doi:10.4172/2168-9784.1000139 · Cited by 1
Distinguishing Syncope From Seizures: How Useful is the Clinical History?
Sheldon, R. S. (2004) · Springer eBooks · doi:10.1007/978-88-470-2137-2_77 · Cited by 1
Pacing in Neurally Mediated Syncope Syndromes
Berecki-Gisolf, J., & Sheldon, R. S. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1616-0.00015-1 · Cited by 1
OBSOLETE: Electrocardiographic Monitoring Strategies (Holter, Implantable Loop Recorder, in Between)
Krahn, A. D. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99770-8 · Cited by 1
Pacing in neurocardiogenic/vasovagal syncope
Sutton, R. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-018-0564-0 · Cited by 1
Schuchert, A. (2008) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-008-0011-8 · Cited by 1
Andresen, D. (2014) · Herz · doi:10.1007/s00059-014-4096-z · Cited by 1
Mechanism of action of antiarrhythmic drugs
Mazumdar, H., Bhowmik, R., Shaharyar, M. A., Mandal, A., Anand, K., Patra, S., Kumari, R., Jana, S., Haldar, P. K., & Karmakar, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-99855-0.00013-0 · Cited by 1
Matsumoto, K., Kodama, Y., Ito, S., Nakamura, Y., Fujiwara, R., Kajio, K., Kasamatsu, K., Murata, E., Nakamura, Y., & Kawase, Y. (2022) · Heart and Vessels · doi:10.1007/s00380-022-02212-x · Cited by 1
Chen, L. Y., & Benditt, D. G. (2010) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2010.01881.x · Cited by 1
Epileptische und nicht-epileptische Anfälle
Korinthenberg, R., Panteliadis, C. P., Ramantani, G., Stephani, U., Trinka, E., & Unterberger, I. (2014) · Elsevier eBooks · doi:10.1016/b978-3-437-23076-9.00007-3 · Cited by 1
Synkopenmanagement in der Praxis
Oebel, S., & Hindricks, G. (2018) · Herz · doi:10.1007/s00059-018-4757-4 · Cited by 1
Diagnostic Tools to Assess Dysfunction of Autonomic Control of the Heart
Lakkireddy, D. (2020) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2402 · Cited by 1
Recurrent Syncope in a Patient With Bifascicular Block
Cao, Y., Wang, F., & Wu, H.-Y. (2021) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2021.6599 · Cited by 1
Implantable cardiac monitors: State of the art
Jamal, S. M., Prasad, R. M., Vipparla, N. S., Srivastava, S., Baloch, Z. Q., Banga, E., & Ip, J. H. (2021) · Interventional Cardiology · Cited by 1
Recording Ambulatory Blood Pressure in the Syncope and TLOC Evaluation
Andresen, D. (2007) · doi:10.1002/9780470692639.ch11 · Cited by 1
Sutton, R. (2007) · Wiley eBooks · doi:10.1002/9780470692639.ch16 · Cited by 1
Eltahawy, E. A., & Grubb, B. P. (2007) · Springer eBooks · doi:10.1007/978-0-387-72763-9_13 · Cited by 1
Evaluation of Suspected Arrhythmic Syncope: Leaning Away from Tilting
Kaufman, E. S. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2005.50243.x · Cited by 1
Recurrent falls: pace now or wait for another fall?
Ermiş, C., & Benditt, D. G. (2009) · Heart · doi:10.1136/hrt.2008.154948 · Cited by 1
An Update on the Treatment of Vasovagal Syncope
Brignole, M. (2004) · Cited by 1
Self-citationOrthostatic Hypotension and Autonomic Dysfunction Syndromes
Raj, S. R., & Robertson, D. (2005) · Elsevier eBooks · doi:10.1016/b978-0-7216-0258-5.50150-2 · Cited by 1
The Use of Implantable Loop Recorders
Krahn, A. D., Klein, G. J., Skanes, A. C., & Yee, R. K. (2004) · Elsevier eBooks · doi:10.1016/b0-7216-0323-8/50088-9
Prevention of Vasovagal Syncope by Pacing: How to Select Patients and Which Pacing Mode to Choose
Brignole, M. (2002) · Springer eBooks · doi:10.1007/978-88-470-2103-7_14
Self-citationBenito, M. L. (2012) · Gredos (University of Salamanca) · doi:10.14201/gredos.115649
Metadata
- Authors
- Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators
- Affiliations
- From the Departments of Cardiology of Hospital Vall d’Hebron, Barcelona, Spain (A.M.); Ospedali Riuniti, Lavagna, Italy (M.B.); Ospedale S Maria Nuova, Reggio Emilia, Italy (C.M.); Hospital Clinico Universitario, Valencia, Spain (R.G.-C.); Ospedale Villa Maria, Piombino, Italy (S.T.); Hospital Clinico, Barcelona, Spain (L.M.); Ospedale Umberto I, Mestre, Italy (F.G.); Ospedale S. Anna, Como, Italy (G.B.); Ospedale per gli Infermi, Faenza, Italy (D.C.).
- Hospital Clínico Universitario de Valencia (ES)
- Venue
- Circulation
- Published
- 2001-09-11
- Volume
- 104
- Issue
- 11
- Pages
- 1261-1267
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2135058841
- Cited by
- 378
- References
- 13
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 7 · 2023: 4 · 2022: 7 · 2021: 13 · 2020: 8 · 2019: 3 · 2018: 13 · 2017: 21 · 2016: 16 · 2015: 9 · 2014: 22 · 2013: 27 · 2012: 18
- FWCI
- 19.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Circulation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- syncope, implantable loop recorder, sinus arrest, neurally mediated syncope, vasodepressor syncope, presyncope, syncope recurrence, syncope mechanism
- MeSH terms
- Adult, Aged, Aged, 80 and over, Bradycardia, Cardiac Pacing, Artificial, Electrocardiography, Female, Humans, Male, Middle Aged, Recurrence, Syncope, Tachycardia, Tilt-Table Test
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review