CoChat

Noninvasive Determination of Spatially Resolved and Time-Resolved Tissue Perfusion in Humans During Nitric Oxide Inhibition and Inhalation by Use of a Visible-Reflectance Hyperspectral Imaging Technique

Open access
Zuzak, Karel J., Schaeberle, Michael D., Gladwin, Mark T., Cannon, Richard O., Levin, Ira W. · 2001 · Circulation
Cited by 75

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background — Vascular disease is commonly associated with reduced local synthesis of nitric oxide (NO) and impaired tissue perfusion. We introduce a novel noninvasive, visible-reflectance, hyperspectral imaging technique for quantifying the percentage of hemoglobin existing as oxyhemoglobin (HbO 2 ) as an index of skin tissue perfusion. Methods and Results — To simulate vascular endothelial dysfunction, N G -monomethyl- l -arginine (L-NMMA) was infused into the brachial arteries of 9 healthy subjects for 5 minutes to inhibit forearm NO synthesis, first with the subject breathing room air and subsequently during NO inhalation at 80 ppm for 1 hour. Blood flow was measured by venous occlusion plethysmography, and the percentage of HbO 2 perfusing skin tissue was imaged noninvasively with a visible-reflectance hyperspectral technique. L-NMMA reduced blood flow by 31.7±4.9% and percentage of HbO 2 by 6.5±0.1 ( P =0.002 and P <0.001 versus baseline, respectively). With subjects inhaling NO, blood flow fell during L-NMMA infusion by only 10.9±7.3%, and the percentage of HbO 2 decreased by 3.6±0.1 ( P =0.007 and P <0.001, respectively, versus room air L-NMMA responses). Conclusions — Visible-reflectance hyperspectral imaging demonstrates (1) a significant decline in the percentage of HbO 2 in skin tissue when blood flow is reduced after inhibition of forearm NO synthesis and (2) restoration of HbO 2 toward basal values with improved blood flow during inhalation of NO. This imaging method may provide an effective approach for time-resolved noninvasive monitoring of skin hemoglobin oxygen saturation and assessment of responses to therapeutic interventions in patients with vascular disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hc4901.100525

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 75

Metadata

Authors
Zuzak, K. J., Schaeberle, M. D., Gladwin, M. T., Cannon, R. O., & Levin, I. W.
Venue
Circulation
Published
2001-12-11
Volume
104
Issue
24
Pages
2905-2910
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2165943204
Cited by
75
References
5
FWCI
0.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.