CoChat
Cited by 166

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Peripheral Augmentation Index Defines the Relationship Between Central and Peripheral Pulse Pressure

Open access
Munir, Shahzad, Guilcher, Antoine, Kamalesh, Tamra, Clapp, Brian, Redwood, Simon, Marber, Michael, Chowienczyk, Philip · 2008 · Hypertension

Abstract

Peripheral systolic blood pressure is amplified above central aortic systolic pressure, but the late systolic shoulder of the peripheral pulse may approximate central systolic pressure. Because late systolic pressure also determines the peripheral augmentation index, a measure of pressure wave reflection within the systemic circulation, this implies a direct relationship between amplification and augmentation. We compared the late systolic shoulder of the peripheral pressure waveform with estimates of central systolic pressure obtained using a transfer function in 391 subjects undergoing diagnostic coronary angiography and/or elective angioplasty (30% with insignificant coronary artery disease). In a subset (n=12) we compared the late systolic shoulder of the peripheral pulse with central pressure obtained with a catheter placed in the aortic root. Measurements were made at baseline, during atrial pacing, and during administration of nitroglycerin. Late systolic shoulder pressure closely approximated transfer function estimates of central pressure ( R =0.96; P <0.0001; mean difference±SD: 0.5±5.2 mm Hg). Despite changes in waveform morphology induced by pacing and nitroglycerin (reducing mean values±SE of the augmentation index from 76±3.8% to 66±4.6% and 60±3.3%, respectively), there was close agreement between the late systolic shoulder of the peripheral pulse and measured values of central pressure ( R =0.96; P <0.001; mean difference: 1.7±4.8 mm Hg). In conclusion, the late systolic shoulder of the peripheral pulse closely approximates central systolic pressure and peripheral augmentation index, the ratio of central:peripheral pulse pressure. Interventions to lower augmentation index and peripheral vascular resistance will have multiplicative effects in lowering central blood pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/hypertensionaha.107.096016

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 166

Metadata

Authors
Munir, S., Guilcher, A., Kamalesh, T., Clapp, B., Redwood, S., Marber, M., & Chowienczyk, P.
Venue
Hypertension
Published
2008-01
Volume
51
Issue
1
Pages
112-118
ISSN
  • 0194-911X (ISSN-L)
  • 1524-4563
OpenAlex
W2114268392
Cited by
166
References
4
FWCI
4.97
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Peripheral Augmentation Index Defines the Relationship Between Central and Peripheral Pulse Pressure. https://app.cochat.ai/papers/10.1161/hypertensionaha.107.096016
The paper
Munir, S., Guilcher, A., Kamalesh, T., Clapp, B., Redwood, S., Marber, M., & Chowienczyk, P. (2008). Peripheral Augmentation Index Defines the Relationship Between Central and Peripheral Pulse Pressure. Hypertension. https://doi.org/10.1161/hypertensionaha.107.096016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.