Peripheral Augmentation Index Defines the Relationship Between Central and Peripheral Pulse Pressure
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Peripheral systolic blood pressure is amplified above central aortic systolic pressure, but the late systolic shoulder of the peripheral pulse may approximate central systolic pressure. Because late systolic pressure also determines the peripheral augmentation index, a measure of pressure wave reflection within the systemic circulation, this implies a direct relationship between amplification and augmentation. We compared the late systolic shoulder of the peripheral pressure waveform with estimates of central systolic pressure obtained using a transfer function in 391 subjects undergoing diagnostic coronary angiography and/or elective angioplasty (30% with insignificant coronary artery disease). In a subset (n=12) we compared the late systolic shoulder of the peripheral pulse with central pressure obtained with a catheter placed in the aortic root. Measurements were made at baseline, during atrial pacing, and during administration of nitroglycerin. Late systolic shoulder pressure closely approximated transfer function estimates of central pressure ( R =0.96; P <0.0001; mean difference±SD: 0.5±5.2 mm Hg). Despite changes in waveform morphology induced by pacing and nitroglycerin (reducing mean values±SE of the augmentation index from 76±3.8% to 66±4.6% and 60±3.3%, respectively), there was close agreement between the late systolic shoulder of the peripheral pulse and measured values of central pressure ( R =0.96; P <0.001; mean difference: 1.7±4.8 mm Hg). In conclusion, the late systolic shoulder of the peripheral pulse closely approximates central systolic pressure and peripheral augmentation index, the ratio of central:peripheral pulse pressure. Interventions to lower augmentation index and peripheral vascular resistance will have multiplicative effects in lowering central blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
The CAFE Investigators, CAFE Steering Committee and Writing Committee, Williams, B., Lacy, P. S., Thom, S. M., Cruickshank, K., Stanton, A., Collier, D., Hughes, A. D., Thurston, H., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.595496 · Cited by 1,645
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
Vlachopoulos, C., O'Rourke, M., & Nichols, W. W. (2011) · doi:10.1201/b13568 · Cited by 1,613
The influence of heart rate on augmentation index and central arterial pressure in humans
Wilkinson, I. B., MacCallum, H., Flint, L., Cockcroft, J. R., Newby, D. E., & Webb, D. J. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-1-00263.x · Cited by 1,091
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
Arterial wave reflections and survival in end-stage renal failure
London, G. M., Blacher, J., Pannier, B., Guérin, A. P., Marchais, S. J., & Safar, M. E. (2001) · Hypertension · doi:10.1161/01.hyp.38.3.434 · Cited by 853
Mechanical Principles in Arterial Disease
O’Rourke, M. (1995) · Hypertension · doi:10.1161/01.hyp.26.1.2 · Cited by 401
Wilkinson, I. B., Hall, I. R., MacCallum, H., Mackenzie, I. S., McEniery, C. M., van der Arend, B. J., Shu, Y.-E., MacKay, L. S., Webb, D. J., & Cockcroft, J. R. (2002) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/hq0102.101770 · Cited by 371 · cited 1×
“Nonsignificant disease† 117 (30) Single vessel 97 ( 25 ) Multivessel 192 (49)”
Photoplethysmographic assessment of pulse wave reflection
Chowienczyk, P. J., Kelly, R. P., MacCallum, H., Millasseau, S. C., Andersson, T. L. G., Gosling, R. G., Ritter, J. M., & Änggård, E. E. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00441-6 · Cited by 363
Self-citationHeart rate dependency of pulse pressure amplification and arterial stiffness
Wilkinson, I. B., Mohammad, N. H., Tyrrell, S., Hall, I. R., Webb, D. J., Paul, V. E., Levy, T., & Cockcroft, J. R. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02252-x · Cited by 357
Does Radial Artery Pressure Accurately Reflect Aortic Pressure?
Pauca, A. L., Wallenhaupt, S. L., Kon, N. D., & Tucker, W. Y. (1992) · Chest · doi:10.1378/chest.102.4.1193 · Cited by 341
KELLY, R. P., GIBS, H. H., O'ROURKE, M. F., DALEY, J. E., MANG, K., MORGEN, J. J., & AVOLID, A. P. (1990) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a059669 · Cited by 312
Noninvasive Assessment of the Digital Volume Pulse: Comparison With the Peripheral Pressure Pulse
Millasseau, S. C., Guigui, F. G., Kelly, R. P., Prasad, K., Cockcroft, J. R., Ritter, J. M., & Chowienczyk, P. J. (2000) · Hypertension · doi:10.1161/01.hyp.36.6.952 · Cited by 294
Self-citationPressure Amplification Explains Why Pulse Pressure Is Unrelated to Risk in Young Subjects
Wilkinson, I. B., Franklin, S. S., Hall, I. R., Tyrrell, S., & Cockcroft, J. R. (2001) · Hypertension · doi:10.1161/hy1201.097723 · Cited by 273
Pressure Wave Reflection Assessed From the Peripheral Pulse: Is a Transfer Function Necessary?
Millasseau, S. C., Patel, S. J., Redwood, S. R., Ritter, J. M., & Chowienczyk, P. J. (2003) · Hypertension · doi:10.1161/01.hyp.0000057574.64076.a5 · Cited by 204
Self-citationGALLAGHER, D., ADJI, A., & OROURKE, M. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.05.027 · Cited by 194
Increased augmentation index and systolic stress in type 1 diabetes mellitus
Wilkinson, I. B. (2000) · QJM · doi:10.1093/qjmed/93.7.441 · Cited by 193
Lacy, P. S., O'Brien, D. G., Stanley, A. G., Dewar, M. M., Swales, P. P., & Williams, B. (2004) · Journal of Hypertension · doi:10.1097/00004872-200410000-00016 · Cited by 178
Assessment of endothelial function using peripheral waveform analysis
Hayward, C. S., Kraidly, M., Webb, C. M., & Collins, P. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01991-5 · Cited by 170
Use of arterial transfer functions for the derivation of aortic waveform characteristics
Hope, S. A., Tay, D. B. H., Meredith, I. T., & Cameron, J. D. (2003) · Journal of Hypertension · doi:10.1097/00004872-200307000-00017 · Cited by 160
Rourke, M. F. O., & Adji, A. I. (2005) · Current Opinion in Cardiology · doi:10.1097/01.hco.0000166595.44711.6f · Cited by 138
Estimation of central aortic pressure by SphygmoCor® requires intra-arterial peripheral pressures
CLOUD, G. C., Rajkumar, C., Kooner, J. S., COOKE, J., & Bulpitt, C. J. (2003) · Clinical Science · doi:10.1042/cs20030012 · Cited by 134
Augmentation of central arterial pressure in Type 2 diabetes
Brooks, B. A., Molyneaux, L. M., & Yue, D. K. (2001) · Diabetic Medicine · doi:10.1046/j.1464-5491.2001.00479.x · Cited by 123
Pauca, A. L., Kon, N. D., & O’Rourke, M. F. (2004) · British Journal of Anaesthesia · doi:10.1093/bja/aeh121 · Cited by 123 · cited 1×
“The difference between pSBP2 and cSBP was significantly less than that between pSBP and cSBP (11 [7] mm Hg; P 0.”
BackgroundAugmentation of the aortic and central arterial pressure waveform
O??Rourke, M. F., & Pauca, A. L. (2004) · Blood Pressure Monitoring · doi:10.1097/00126097-200408000-00002 · Cited by 112
Heritability of Central Systolic Pressure Augmentation: A Twin Study
Snieder, H., Hayward, C. S., Perks, U., Kelly, R. P., Kelly, P. J., & Spector, T. D. (2000) · Hypertension · doi:10.1161/01.hyp.35.2.574 · Cited by 86
Fukui, M., Kitagawa, Y., Nakamura, N., Mogami, S.-I., Ohnishi, M., Hirata, C., Ichio, N., Wada, K., Kamiuchi, K., Shigeta, M., et al. (2003) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(02)00204-8 · Cited by 34
Cited by
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Avolio, A. P., Van Bortel, L. M., Boutouyrie, P., Cockcroft, J. R., McEniery, C. M., Protogerou, A. D., Roman, M. J., Safar, M. E., Segers, P., & Smulyan, H. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134379 · Cited by 521
Avolio, A. P., Butlin, M., & Walsh, A. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/1/r01 · Cited by 310
Arterial Stiffness and Hypertension: Emerging Concepts
Payne, R. A., Wilkinson, I. B., & Webb, D. J. (2010) · Hypertension · doi:10.1161/hypertensionaha.107.090464 · Cited by 244
Exercise reduces arterial pressure augmentation through vasodilation of muscular arteries in humans
Munir, S., Jiang, B., Guilcher, A., Brett, S., Redwood, S., Marber, M., & Chowienczyk, P. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01171.2007 · Cited by 175
Self-citation
Metadata
- Authors
- Munir, S., Guilcher, A., Kamalesh, T., Clapp, B., Redwood, S., Marber, M., & Chowienczyk, P.
- Venue
- Hypertension
- Published
- 2008-01
- Volume
- 51
- Issue
- 1
- Pages
- 112-118
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2114268392
- Cited by
- 166
- References
- 27
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.