CoChat

Glycemic Index, Retinal Vascular Caliber, and Stroke Mortality

Open access
Kaushik, Shweta, Wang, Jie Jin, Wong, Tien Y., Flood, Victoria, Barclay, Alan, Brand-Miller, Jennie, Mitchell, Paul · 2009 · Stroke
Cited by 74

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Background and Purpose— It is unclear whether diets with high glycemic index (GI) and low cereal fiber (CF) are associated with greater risk of stroke. We aimed to assess the relationship between dietary GI and CF content, retinal microvasculature changes, and stroke-related mortality. Methods— The study consisted of a population-based cohort, 49+ years, examined at baseline (1992 to 1994). At baseline, participants completed validated food frequency questionnaires. Mean GI was calculated using an Australian database. Retinal arteriolar and venular diameters were measured from photographs. Mortality data were derived using the Australian National Death Index. Results— Over 13 years, 95 of 2897 participants (3.5%) died from stroke. Increasing GI (hazard ratio, 1.91; 95% CI, 1.01 to 3.47, highest versus lowest tertile) and decreasing CF (hazard ratio, 2.13; 95% CI, 1.19 to 3.80, lowest versus highest tertile) predicted greater risk of stroke death adjusting for multiple stroke risk factors. Persons consuming food in the highest GI tertile and lowest CF tertile had a 5-fold increased risk of stroke death (hazard ratio, 5.06; 95% CI, 1.67 to 15.22). Increasing GI and decreasing CF were also associated with retinal venular caliber widening ( P trend <0.01). Adjustment for retinal venular caliber attenuated stroke death risk associated with high GI by 50% but did not affect the risk associated with low CF consumption. Conclusions— High-GI and low-CF diets predict greater stroke mortality and wider retinal venular caliber. The association between a high-GI diet and stroke death was partly explained by GI effects on retinal venular caliber, suggesting that a high-GI diet may produce deleterious anatomic changes in the microvasculature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/strokeaha.108.513812

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 74

Metadata

Authors
Kaushik, S., Wang, J. J., Wong, T. Y., Flood, V., Barclay, A., Brand-Miller, J., & Mitchell, P.
Venue
Stroke
Published
2009-01
Volume
40
Issue
1
Pages
206-212
ISSN
  • 0039-2499 (ISSN-L)
  • 1524-4628
OpenAlex
W2164543201
Cited by
74
References
12
FWCI
4.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glycemic Index, Retinal Vascular Caliber, and Stroke Mortality. https://app.cochat.ai/papers/10.1161/strokeaha.108.513812
The paper
Kaushik, S., Wang, J. J., Wong, T. Y., Flood, V., Barclay, A., Brand-Miller, J., & Mitchell, P. (2009). Glycemic Index, Retinal Vascular Caliber, and Stroke Mortality. Stroke. https://doi.org/10.1161/strokeaha.108.513812

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.