Laboratory Diagnostics and Quality of Blood Collection / Laboratorijska Dijagnostika I Kvalitet Uzimanja Uzoraka Krvi
Open accessThe DOI matches its Crossref record, with a small difference in title or year; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Summary: Diagnostic blood samples collected by phlebotomy are the most common type of biological specimens drawn and sent to laboratory medicine facilities for being analyzed, thus supporting caring physicians in patient diagnosis, follow-up and/or therapeutic monitoring. Phlebotomy, a relatively invasive medical procedure, is indeed critical for the downstream procedures accomplished either in the analytical phase made in the laboratory or in the interpretive process done by the physicians. Diagnosis, management, treatment of patients and ultimately patient safety itself can be compromised by poor phlebotomy quality. We have read with interest a recent article where the authors addressed important aspects of venous blood collection for laboratory medicine analysis. The authors conducted a phlebotomy survey based on the Clinical and Laboratory Standard Institute (CLSI) H03-A6 document (presently replaced by the GP41-A6 document) in three government hospitals in Ethiopia to evaluate 120 professionals (101 non-laboratory professionals vs. 19 laboratory professionals) as regards the venous blood collection practice. The aim of this mini (non-systematic) review is to both take a cue from the above article and from current practices we had already observed in other laboratory settings, and discuss four questionable activities performed by health care professionals during venous blood collection. We refer to: i) diet restriction assessment; ii) puncture site cleansing; iii) timing of tourniquet removal and; iv) mixing specimen with additives
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Protons in ischemia: Where do they come from; Where do they go to?
Dennis, S. (1991) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(91)91642-5 · Cited by 343
Lipemia: causes, interference mechanisms, detection and management
Nikolac, N. (2014) · Biochemia Medica · doi:10.11613/bm.2014.008 · Cited by 290
Standardization of collection requirements for fasting samples
Simundic, A. M., Cornes, M., Grankvist, K., Lippi, G., & Nybo, M. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.11.008 · Cited by 156
Self-citationLowe, G., Stike, R., Pollack, M., Bosley, J., O'brien, P., Hake, A., Landis, G., Billings, N., Gordon, P., Manzella, S., et al. (2008) · Journal of Emergency Nursing · doi:10.1016/j.jen.2007.02.006 · Cited by 127
Nikolac, N., Šupak Smolčić, V., Šimundić, A.-M., & Ćelap, I. (2013) · Biochemia Medica · doi:10.11613/bm.2013.031 · Cited by 99 · cited 2×
“Diagnosis, management, treatment of patients and ultimately patient safety itself can be compromised by poor phlebotomy quality (5).”
BackgroundInfluence of a light meal on routine haematological tests.
(2010) · PubMed Central · doi:10.2450/2009.0142-09 · Cited by 71
Self-citationHemolysis index: quality indicator or criterion for sample rejection?
Plebani, M., & Lippi, G. (2009) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2009.229 · Cited by 70
Self-citationYamada, K., Yamada, K., Katsuda, I., & Hida, T. (2008) · Clinical Anatomy · doi:10.1002/ca.20622 · Cited by 70
Reducing Preanalytical Laboratory Sample Errors Through Educational and Technological Interventions
Lillo, R., Salinas, M., López‐Garrigós, M., Naranjo-Santana, Y., Gutirrez, M., Marn, M. D., Miralles, M., & Uris, J. (2012) · Clinical Laboratory · doi:10.7754/clin.lab.2012.111111 · Cited by 66
Research works printed but not linked: 2
- Geneva, 2010, WHO Guidelines on Drawing Blood : Best Practices in Phlebotomy, World Health Organization World Health Organization press
- Lippi, 2008, Recommendations for collection of venous blood, Biochim Clin, 32, 569
Cited by
Aydin, S., Emre, E., Ugur, K., Aydin, M. A., Sahin, İ., Cinar, V., & Akbulut, T. (2025) · Journal of International Medical Research · doi:10.1177/03000605251315913 · Cited by 195
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationCauses, consequences and management of sample hemolysis in the clinical laboratory
Heireman, L., Geel, P. V., Musger, L., Heylen, E., Uyttenbroeck, W., & Mahieu, B. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.09.013 · Cited by 172
Lima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationAkhlaghi, A. A., Kaur, H., Adhikari, B. R., & Soleymani, L. (2024) · ECS Sensors Plus · doi:10.1149/2754-2726/ad304a · Cited by 91
Metadata
- Authors
- Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Picheth, G., & Guidi, G. C.
- Affiliations
- University of Verona (IT)
- University of Parma (IT)
- Universidade Federal do Paraná (BR)
- Corresponding author
- Lima-Oliveira, Gabriel
- Venue
- Journal of Medical Biochemistry
- Published
- 2015-07-01
- Volume
- 34
- Issue
- 3
- Pages
- 288-294
- ISSN
- 1452-8266 (ISSN-L)
- PMC
- PMC4922344
- OpenAlex
- W2104584457
- Semantic Scholar
- 3f558b354288b258c969aea8d04ebf1db976baac
- Cited by
- 102
- References
- 34
- Citations by year
- 2026: 7 · 2025: 17 · 2024: 17 · 2023: 10 · 2022: 3 · 2021: 6 · 2020: 5 · 2019: 6 · 2018: 3 · 2017: 10 · 2016: 10 · 2015: 4
- FWCI
- 1.09
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- Journal of Medical Biochemistry (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Hematology › Blood donation and transfusion practices
- Keywords
- phlebotomy, venous blood collection, blood sample quality, laboratory workers, patient safety
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laboratory Diagnostics and Quality of Blood Collection / Laboratorijska Dijagnostika I Kvalitet Uzimanja Uzoraka Krvi. https://app.cochat.ai/papers/10.2478/jomb-2014-0043
- The paper
- Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Picheth, G., & Guidi, G. C. (2015). Laboratory Diagnostics and Quality of Blood Collection / Laboratorijska Dijagnostika I Kvalitet Uzimanja Uzoraka Krvi. Journal of Medical Biochemistry. https://doi.org/10.2478/jomb-2014-0043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.