CoChat

Laboratory Diagnostics and Quality of Blood Collection / Laboratorijska Dijagnostika I Kvalitet Uzimanja Uzoraka Krvi

Open access

The DOI matches its Crossref record, with a small difference in title or year; 34 of the 34 references it cites were found in a registry or an index.

Abstract

Summary: Diagnostic blood samples collected by phlebotomy are the most common type of biological specimens drawn and sent to laboratory medicine facilities for being analyzed, thus supporting caring physicians in patient diagnosis, follow-up and/or therapeutic monitoring. Phlebotomy, a relatively invasive medical procedure, is indeed critical for the downstream procedures accomplished either in the analytical phase made in the laboratory or in the interpretive process done by the physicians. Diagnosis, management, treatment of patients and ultimately patient safety itself can be compromised by poor phlebotomy quality. We have read with interest a recent article where the authors addressed important aspects of venous blood collection for laboratory medicine analysis. The authors conducted a phlebotomy survey based on the Clinical and Laboratory Standard Institute (CLSI) H03-A6 document (presently replaced by the GP41-A6 document) in three government hospitals in Ethiopia to evaluate 120 professionals (101 non-laboratory professionals vs. 19 laboratory professionals) as regards the venous blood collection practice. The aim of this mini (non-systematic) review is to both take a cue from the above article and from current practices we had already observed in other laboratory settings, and discuss four questionable activities performed by health care professionals during venous blood collection. We refer to: i) diet restriction assessment; ii) puncture site cleansing; iii) timing of tourniquet removal and; iv) mixing specimen with additives

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2478/jomb-2014-0043

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Schematic representation of the effects of stasis induced by tourniquet application on blood constituents. Normal flow of blood through an unobstructed vein (Figure 1-A). The obstruction due to tourniquet reduces blood flow thus creating venous stasis (Figure 1-B) with net efflux of water from the vessel to the interstice. Elements of low molecular mass diffuse with water whereas high molecular weight compounds and cells concentrate in the vein.
Figure 1 Schematic representation of the effects of stasis induced by tourniquet application on blood constituents. Normal flow of blood through an unobstructed vein (Figure 1-A). The obstruction due to tourniquet reduces blood flow thus creating venous stasis (Figure 1-B) with net efflux of water from the vessel to the interstice. Elements of low molecular mass diffuse with water whereas high molecular weight compounds and cells concentrate in the vein.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 34 references

Research works printed but not linked: 2

  1. Geneva, 2010, WHO Guidelines on Drawing Blood : Best Practices in Phlebotomy, World Health Organization World Health Organization press
  2. Lippi, 2008, Recommendations for collection of venous blood, Biochim Clin, 32, 569

Cited by

See all 113

Metadata

Authors
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Picheth, G., & Guidi, G. C.
Affiliations
  • University of Verona (IT)
  • University of Parma (IT)
  • Universidade Federal do Paraná (BR)
Corresponding author
Lima-Oliveira, Gabriel
Venue
Journal of Medical Biochemistry
Published
2015-07-01
Volume
34
Issue
3
Pages
288-294
ISSN
1452-8266 (ISSN-L)
OpenAlex
W2104584457
Cited by
102
References
34
Citations by year
2026: 7 · 2025: 17 · 2024: 17 · 2023: 10 · 2022: 3 · 2021: 6 · 2020: 5 · 2019: 6 · 2018: 3 · 2017: 10 · 2016: 10 · 2015: 4
FWCI
1.09
Type
journal article
Language
en
Open access
Locations
  • Journal of Medical Biochemistry (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
  • Health Sciences › Medicine › Hematology › Blood donation and transfusion practices
Keywords
phlebotomy, venous blood collection, blood sample quality, laboratory workers, patient safety

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laboratory Diagnostics and Quality of Blood Collection / Laboratorijska Dijagnostika I Kvalitet Uzimanja Uzoraka Krvi. https://app.cochat.ai/papers/10.2478/jomb-2014-0043
The paper
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Picheth, G., & Guidi, G. C. (2015). Laboratory Diagnostics and Quality of Blood Collection / Laboratorijska Dijagnostika I Kvalitet Uzimanja Uzoraka Krvi. Journal of Medical Biochemistry. https://doi.org/10.2478/jomb-2014-0043

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.