Thermoacoustic Molecular Imaging of Small Animals
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
We have designed, constructed, and tested a thermoacoustic computed tomography (TCT) scanner for imaging optical absorption in small animals in three dimensions. The device utilizes pulsed laser irradiation (680–1064 nm) and a unique, 128-element transducer array. We quantified the isotropic spatial resolution of this scanner to be 0.35 mm. We describe a dual-wavelength subtraction technique for isolating optical dyes with TCT. Phantom experiments demonstrate that we can detect 5 fmol of a near-infrared dye (indocyanine green, ICG) in a 1-ML volume using dual-wavelength subtraction. Initial TCT imaging in phantoms and in two sacrificed mice suggests that three-dimensional, optical absorption patterns in small animals can be detected with an order of magnitude better spatial resolution and an order of magnitude better low-contrast detectability in small animals when compared to fluorescence imaging or diffusion optical tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Photoacoustic ultrasound (PAUS)—Reconstruction tomography
Kruger, R. A., Liu, P., Fang, Y. “., & Appledorn, C. R. (1995) · Medical Physics · doi:10.1118/1.597429 · Cited by 572 · cited 1×
“We reported a methodology for forming thermoacoustic computed tomography (TCT) images of tissuemimicking phantoms using a Neodymium (3+)-doped Yttrium Aluminum Garnet (Nd:YAG) laser in 1995 [19].”
MethodSelf-citationPogue, B. W., Poplack, S. P., McBride, T. O., Wells, W. A., Osterman, K. S., Österberg, U. L., & Paulsen, K. D. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja51261 · Cited by 471
Novel Receptor-Targeted Fluorescent Contrast Agents for In Vivo Tumor Imaging
Achilefu, S. A., Dorshow, R. B., Bugaj, J. E., & Rajagopalan, R. (2000) · Investigative Radiology · doi:10.1097/00004424-200008000-00004 · Cited by 310 · cited 1×
“In this regard, fluorescence techniques are most commonly used [3,4].”
MethodNear-Infrared Optical Imaging of Protease Activity for Tumor Detection
Mahmood, U., Tung, C.-H., Bogdanov, A., & Weissleder, R. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc14866 · Cited by 301
Optical image reconstruction using frequency-domain data: simulations and experiments
Jiang, H., Pogue, B. W., Patterson, M. S., Paulsen, K. D., & Osterberg, U. L. (1996) · Journal of the Optical Society of America A · doi:10.1364/josaa.13.000253 · Cited by 260
Spectroscopy enhances the information content of optical mammography
Cerussi, A. E., Jakubowski, D., Shah, N., Bevilacqua, F., Lanning, R., Berger, A. J., Hsiang, D., Butler, J., Holcombe, R. F., & Tromberg, B. J. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1427050 · Cited by 172 · cited 1×
“Multispectral, optical imaging techniques have also been proposed for characterizing endogenous tissues on the basis of their spectral absorption properties [5,6].”
BackgroundNtziachristos, V., & Weissleder, R. (2002) · Medical Physics · doi:10.1118/1.1470209 · Cited by 153 · cited 4×
“Abbreviations: CCD, charge-coupled device; CNR, contrast-to-noise ratio; CT, computed tomography; DOT, diffusion optical tomography; FMT, fluorescence-mediated tomography; ICG, indocyanine green; ID, inside diameter; IFFT, inverse fast Fourier transform; LSF, line spread function; MRI, magnetic resonance imaging; mL,…”
BackgroundResultInfluentialIn Vivo Tomographic Imaging of Near-Infrared Fluorescent Probes
Ntziachristos, V., Bremer, C., Graves, E. E., Ripoll, J., & Weissleder, R. (2002) · Molecular Imaging · doi:10.1162/153535002320162732 · Cited by 141 · cited 1×
“More recently, FMT has been used successfully to image an implanted tumor in a nude mouse [14].”
MethodKruger, R. A. (1994) · Medical Physics · doi:10.1118/1.597367 · Cited by 130
Self-citationReconstruction methods for infrared absorption imaging
Arridge, S., van der Zee, P., Cope, M., & Delpy, D. T. (1991) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.44191 · Cited by 110
Molecular–Genetic Imaging: A Nuclear Medicine–Based Perspective
Blasberg, R. G., & Gelovani, J. G. (2002) · Molecular Imaging · doi:10.1162/15353500200202127 · Cited by 109
Radiation-Induced Thermoacoustic Soft Tissue Imaging
Bowen, T. (1981) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1981.197737 · Cited by 107 · cited 1×
“[15,16] first recognized the potential of inducing thermoacoustic signals in soft tissue.”
BackgroundMcBride, T. O., Pogue, B. W., Poplack, S. P., Soho, S. K., Wells, W. A., Jiang, S., Österberg, U. L., & Paulsen, K. D. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1428290 · Cited by 99 · cited 2×
“At 1064 nm, optical absorption is dominated by the presence of water; at 800 nm, water absorption is virtually nil, and hemoglobin in the blood dominates optical absorption [6].”
BackgroundNear-infrared imaging in the small animal brain: optimization of fiber positions
Xu, H., Dehghani, H., Pogue, B. W., Springett, R., Paulsen, K. D., & Dunn, J. F. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528597 · Cited by 91 · cited 1×
“been described for imaging the brain of a Sprague– Dawley rat [12].”
MethodSome Tools for Molecular Imaging
Mahmood, U., & Weissleder, R. (2002) · Academic Radiology · doi:10.1016/s1076-6332(03)80306-9 · Cited by 18 · cited 1×
“In 1999, over 90% of research into mammalian models of human disease involved small animals, especially mice [1].”
Background
Cited by
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
New Strategies for Fluorescent Probe Design in Medical Diagnostic Imaging
Kobayashi, H., Ogawa, M., Alford, R., Choyke, P. L., & Urano, Y. (2010) · Chemical Reviews · doi:10.1021/cr900263j · Cited by 2,200
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Multiscale photoacoustic microscopy and computed tomography
Wang, L. V. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.157 · Cited by 1,400
Metadata
- Authors
- Kruger, R. A., Kiser, W. L., Reinecke, D. R., Kruger, G. A., & Miller, K. D.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2003-04-01
- Volume
- 2
- Issue
- 2
- Pages
- 113-123
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2130258696
- Cited by
- 187
- References
- 16
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.