PEO-like plasma polymerized tetraglyme surface interactions with leukocytes and proteins: in vitro and in vivo studies
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Polyethylene oxide (PEO) surfaces reduce non-specific protein and cell interactions with implanted biomaterials and may improve their biocompatibility. PEO-like polymerized tetraglyme surfaces were made by glow discharge plasma deposition onto fluorinated ethylene propylene copolymer (FEP) substrates and were shown to adsorb less than 10 ng/cm2 of fibrinogen in vitro. The ability of the polymerized tetraglyme surfaces to resist leukocyte adhesion was studied in vitro and in vivo. Polymerized tetraglyme and FEP were implanted subcutaneously in mice and removed after 1 day or 4 weeks. Histological analysis showed a similar degree of fibrous encapsulation around all of the 4-week implants. Darkly stained wells were present in the fibrous tissues at the tissue-material interface of both FEP and tetraglyme. Scanning electron micrographs showed that in vivo macrophage adhesion to polymerized tetraglyme was much higher than to FEP. After 2-hour contact with heparinized whole blood, polymorphonuclear leukocyte (PMN) adhesion to polymerized tetraglyme was much higher than to FEP, while platelet adhesion to polymerized tetraglyme was lower than to FEP. When PMNs isolated from blood were suspended in 10% autologous plasma, cell adhesion to polymerized tetraglyme was higher than to FEP; however when the cells were suspended in heat inactivated serum, cell adhesion to FEP was higher than to polymerized tetraglyme. The surface chemistry of polymerized tetraglyme did not change after 2-hour blood contact, but displayed nitrogen functional groups after 1-day implantation and became slightly degraded after 4-week implantation. The surface chemistry of FEP did not change significantly after blood contact or implantation. Loosely bound proteins such as fibrinogen on polymerized tetraglyme may contribute to the adhesion of PMNs and macrophages and ultimately to fibrous encapsulation (the foreign body response) around the implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neovascularization of synthetic membranes directed by membrane microarchitecture
Brauker, J. H., Carr‐Brendel, V. E., Martinson, L. A., Crudele, J., Johnston, W. D., & Johnson, R. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291208 · Cited by 517
Self-citationFibrin(ogen) mediates acute inflammatory responses to biomaterials.
Tang, L., & Eaton, J. W. (1993) · The Journal of experimental medicine · doi:10.1084/jem.178.6.2147 · Cited by 449
New ideas in biomaterials science—a path to engineered biomaterials
Ratner, B. D. (1993) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820270702 · Cited by 421
Self-citationBiomaterial biocompatibility and the macrophage
Anderson, J. M., & Miller, K. M. (1984) · Biomaterials · doi:10.1016/0142-9612(84)90060-7 · Cited by 403
Horbett, T. A. (1993) · Cardiovascular Pathology · doi:10.1016/1054-8807(93)90054-6 · Cited by 385
Self-citationIn vitro and in vivo interactions of cells with biomaterials
Ziats, N. P., Miller, K. M., & Anderson, J. M. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90063-4 · Cited by 350
Human plasma fibrinogen adsorption and platelet adhesion to polystyrene
Tsai, W.-B., Grunkemeier, J. M., & Horbett, T. A. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<130::aid-jbm2>3.0.co;2-9 · Cited by 329
Self-citationGrafted poly(ethylene oxide) brushes as nonfouling surface coatings
Leckband, D., Sheth, S., & Halperin, A. (1999) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856299x00720 · Cited by 324
Zhao, Q., Topham, N., Anderson, J. M., Hiltner, A., Lodoen, G., & Payet, C. R. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250205 · Cited by 318
Löpez, G. P., Ratner, B. D., Tidwell, C. D., Haycox, C. L., Rapoza, R. J., & Horbett, T. A. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260402 · Cited by 260
Self-citationComplement C3 participation in monocyte adhesion to different surfaces
McNally, A. K., & Anderson, J. M. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.21.10119 · Cited by 174
Isolation and Properties of Phagocytic Vesicles from Polymorphonuclear Leukocytes
Stossel, T. P., Pollard, T. D., Mason, R. J., & Vaughan, M. (1971) · Journal of Clinical Investigation · doi:10.1172/jci106664 · Cited by 158
Occupancy of CD11b/CD18 (Mac-1) divalent ion binding site(s) induces leukocyte adhesion
Altieri, D. C. (1991) · The Journal of Immunology · doi:10.4049/jimmunol.147.6.1891 · Cited by 149
Binding of fibrinogen to human monocytes.
Altieri, D. C., Mannucci, P. M., & Capitanio, A. M. (1986) · Journal of Clinical Investigation · doi:10.1172/jci112687 · Cited by 128
Suggs, L. J., Shive, M. S., Garcia, C. A., Anderson, J. M., & Mikos, A. G. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199907)46:1<22::aid-jbm3>3.0.co;2-r · Cited by 127
Tang, L., Lucas, A. H., & Eaton, J. W. (1993) · PubMed · Cited by 127
Altankov, G., Thom, V., Groth, T., Jankova, K., Jönsson, G., & Ulbricht, M. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200010)52:1<219::aid-jbm28>3.0.co;2-f · Cited by 121
Jenney, C. R., & Anderson, J. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199902)44:2<206::aid-jbm11>3.0.co;2-d · Cited by 113
Ronneberger, B., Kao, W. J., Anderson, J. M., & Kissel, T. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199601)30:1<31::aid-jbm5>3.0.co;2-s · Cited by 108
Shen, M., Pan, Y. V., Wagner, M. S., Hauch, K. D., Castner, D. G., Ratner, B. D., & Horbett, T. A. (2001) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856201753252507 · Cited by 100
Self-citationJenney, C. R., DeFife, K. M., Colton, E., & Anderson, J. M. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199808)41:2<171::aid-jbm1>3.0.co;2-f · Cited by 91
Optimizing Cell−Surface Interactions by Photografting of Poly(ethylene glycol)
Thom, V. H., Altankov, G., Groth, T., Jankova, K., Jonsson, G., & Ulbricht, M. (2000) · Langmuir · doi:10.1021/la990303a · Cited by 84
The role of superoxide ions in the degradation of synthetic absorbable sutures
Lee, K.-H., & Chu, C. C. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200001)49:1<25::aid-jbm4>3.0.co;2-i · Cited by 74
Blood compatibility of SUUU‐PEO‐heparin graft copolymers
Park, K. D., Kim, W. G., Jacobs, H. A., Okano, T., & Kim, S. W. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260605 · Cited by 71
Polymer substrates for controlled biological interactions
Cima, L. G. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240560206 · Cited by 70
A MAC-1 attack: integrin functions directly challenged in knockout mice.
Plow, E. F., & Zhang, L. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119267 · Cited by 67
Biomaterial‐induced alterations of neutrophil superoxide production
Kaplan, S. S., BASFORD, R. E., Mora, E., Jeong, M. H., & Simmons, R. L. (1992) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820260806 · Cited by 59
Kidane, A., Lantz, G. C., Jo, S., & Park, K. (1999) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856299x00702 · Cited by 48
O’Connor, S. M., Patuto, S. J., Gehrke, S. H., & Retzinger, G. S. (1997) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1997.tb52191.x · Cited by 8
Jenney (2000) · doi:10.1002/(sici)1097-4636(20000315)49:4<435::aid-jbm2>3.0.co;2-y
Shen, M., & Horbett, T. A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20011205)57:3<336::aid-jbm1176>3.0.co;2-e
Self-citation
Cited by
Jiang, S., & Cao, Z. (2010) · Advanced Materials · doi:10.1002/adma.200901407 · Cited by 2,027
Surface hydration: Principles and applications toward low-fouling/nonfouling biomaterials
Chen, S., Li, L., Zhao, C., & Zheng, J. (2010) · Polymer · doi:10.1016/j.polymer.2010.08.022 · Cited by 1,677
Biomaterials: Where We Have Been and Where We Are Going
Ratner, B. D., & Bryant, S. J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140027 · Cited by 1,507
Self-citationChen, S., Zheng, J., Li, L., & Jiang, S. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054169u · Cited by 1,038
Zwitterionic hydrogels implanted in mice resist the foreign-body reaction
Zhang, L., Cao, Z., Bai, T., Carr, L., Ella-Menye, J.-R., Irvin, C., Ratner, B. D., & Jiang, S. (2013) · Nature Biotechnology · doi:10.1038/nbt.2580 · Cited by 1,035
Self-citation
Metadata
- Authors
- Shen, M., Martinson, L., Wagner, M. S., Castner, D. G., Ratner, B. D., & Horbett, T. A.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2002-01
- Volume
- 13
- Issue
- 4
- Pages
- 367-390
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2026077248
- Cited by
- 296
- References
- 31
- FWCI
- 6.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.