Development of perforated microthin poly(ε-caprolactone) films as matrices for membrane tissue engineering
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The design and fabrication of thin films based on bioresorbable polymers such as poly(epsilon-caprolactone) (PCL) has been the focus of a part of current biomedical research, especially as matrices for membrane tissue engineering. We have successfully developed perforated microthin PCL membrane for this purpose. Two critical issues are the control of moisture permeability and understanding the degradation of PCL microthin film. In order to increase the moisture permeability. PCL films were biaxially stretched to a thickness of 10 +/- 3 microm and perforated with uniform array of holes (180-275 microm) using a Sony Robotic system. After perforation, the water vapour transmission rate was increased by 50% to a value of 47.6 +/- 2.7 g/h per m2. Accelerated hydrolytic degradations were performed in 5 M NaOH. The degraded samples were characterised for changes in weight, surface morphology, mechanical properties, crystallinity and molecular weight. Hydrolytic degradation commenced with random chain scission of backbone ester bonds on the film surface and followed by loss of material due to surface erosion. In general, the perforated films degraded faster than the unperforated microthin films. Scanning electron microscopic images showed that surface erosion led to extensive formation of micropores, microcracks and increased in surface roughness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms of polymer degradation and erosion
Göpferich, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85755-3 · Cited by 1,781
Why degradable polymers undergo surface erosion or bulk erosion
Burkersroda, F. V., Schedl, L., & Göpferich, A. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00170-9 · Cited by 1,146
Hydrolytic degradation of devices based on poly(DL-lactic acid) size-dependence
Grizzi, I., Garreau, H., Li, S., & Vert, M. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93258-f · Cited by 895
Ye, W. P., Du, F. S., Jin, W. H., Yang, J. Y., & Xu, Y. (1997) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(96)00081-8 · Cited by 142
Cited by
Degradation mechanisms of polycaprolactone in the context of chemistry, geometry and environment
Bartnikowski, M., Dargaville, T. R., Ivanovski, S., & Hutmacher, D. W. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2019.05.004 · Cited by 769
Self-citationMedical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
Lam, C. X. F., Savalani, M. M., Teoh, S.-H., & Hutmacher, D. W. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/3/034108 · Cited by 444
Self-citationPok, S., Myers, J. D., Madihally, S. V., & Jacot, J. G. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.10.032 · Cited by 215
“PCL, a semi-crystalline, linear, aliphatic polyester formed by ring opening polymerization of caprolactone, is biocompatible, has high tensile strength and has been used in medical devices [25], tissue scaffolds [26,27], and drug delivery systems [28].”
Lam, C. X., Teoh, S. H., & Hutmacher, D. W. (2007) · Polymer International · doi:10.1002/pi.2195 · Cited by 209
Self-citation
Metadata
- Authors
- Htay, A. S., Teoh, S. H., & Hutmacher, D. W.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 2004-01
- Volume
- 15
- Issue
- 5
- Pages
- 683-700
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W2092891700
- Cited by
- 47
- References
- 4
- FWCI
- 1.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.