Surface modification of polymeric biomaterials with poly(ethylene oxide), albumin, and heparin for reduced thrombogenicity
The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Appropriate surface modification has significantly improved the blood compatibility of polymeric biomaterials. This article reviews methods of surface modification with water-soluble polymers, such as polyethylene oxide (PEO), albumin, and heparin. PEO is a synthetic, neutral, water-soluble polymer, while albumin and heparin are a natural globular protein and an anionic polysaccharide, respectively. When grafted onto the surface, all three macromolecules share a common feature to reduce thrombogenicity of biomaterials. The reduced thrombogenicity is due to the unique hydrodynamic properties of the grafted macromolecules. In aqueous medium, surface-bound water-soluble polymers are expected to be highly flexible and extend into the bulk solution. Biomaterials grafted with either PEO, albumin, or heparin are able to resist plasma protein adsorption and platelet adhesion predominantly by a steric repulsion mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peters, T. (1985) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(08)60065-0 · Cited by 2,181
Milner, S. T. (1991) · Science · doi:10.1126/science.251.4996.905 · Cited by 1,821
Hydrogels in Medicine and Pharmacy
Peppas, N. A. (1987) · Cited by 1,648
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., Lee, J. H., Andrade, J. D., & De Gennes, P. G. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90043-8 · Cited by 1,523
Protein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Water structure and changes in thermal stability of the system poly(ethylene oxide)–water
Kjellander, R., & Florin, E. (1981) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19817702053 · Cited by 743
Protein adsorption to poly(ethylene oxide) surfaces
Gombotz, W. R., Guanghui, W., Horbett, T. A., & Hoffman, A. S. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820251211 · Cited by 634
Protein—surface interactions in the presence of polyethylene oxide
Jeon, S. I., & Andrade, J. D. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90044-9 · Cited by 589
Bailey, F. E., & Koleske, J. (1976) · Cited by 565
Napper, D. H. (1977) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(77)90150-3 · Cited by 565
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Polymer brushes: surface-immobilized macromolecules
Zhao, B., & Brittain, W. J. (2000) · Progress in Polymer Science · doi:10.1016/s0079-6700(00)00012-5 · Cited by 1,628
Biomimetic materials for tissue engineering
Ma, P. X. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.041 · Cited by 1,310
Surface Modification of Water Purification Membranes
Miller, D. J., Dreyer, D. R., Bielawski, C. W., Paul, D. R., & Freeman, B. D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201601509 · Cited by 747
In Pursuit of Zero: Polymer Brushes that Resist the Adsorption of Proteins
Hucknall, A., Rangarajan, S., & Chilkoti, A. (2009) · Advanced Materials · doi:10.1002/adma.200900383 · Cited by 552
50th Anniversary Perspective: Polymer Brushes: Novel Surfaces for Future Materials
Chen, W.-L., Cordero, R., Tran, H., & Ober, C. K. (2017) · Macromolecules · doi:10.1021/acs.macromol.7b00450 · Cited by 515
The role of surface science in bioengineered materials
Tirrell, M., Kokkoli, E., & Biesalski, M. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01548-5 · Cited by 447
McPherson, T., Kidane, A., Szleifer, I., & Park, K. (1998) · Langmuir · doi:10.1021/la9706781 · Cited by 433
Self-citationProteins and cells on PEG immobilized silicon surfaces
Zhang, M., Desai, T., & Ferrari, M. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00026-x · Cited by 408
Macromolecular plasma-chemistry: an emerging field of polymer science
DENES, F. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.05.001 · Cited by 374
A microfluidic device for practical label-free CD4+ T cell counting of HIV-infected subjects
Cheng, X., Irimia, D., Dixon, M., Sekine, K., Demirci, U., Zamir, L., Tompkins, R. G., Rodriguez, W., & Toner, M. (2007) · Lab Chip · doi:10.1039/b612966h · Cited by 340
Alginate‐Based Nanofibrous Scaffolds: Structural, Mechanical, and Biological Properties
Bhattarai, N., Li, Z., Edmondson, D., & Zhang, M. (2006) · Advanced Materials · doi:10.1002/adma.200502537 · Cited by 327
Biodegradable block copolymers
Kumar, N., Ravikumar, M. N. V., & Domb, A. J. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00219-8 · Cited by 301
Krishnan, S., Wang, N., Ober, C. K., Finlay, J. A., Callow, M. E., Callow, J. A., Hexemer, A., Sohn, K. E., Kramer, E. J., & Fischer, D. A. (2006) · Biomacromolecules · doi:10.1021/bm0509826 · Cited by 283
Measurements of attractive forces between proteins and end-grafted poly(ethylene glycol) chains
Sheth, S. R., & Leckband, D. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.16.8399 · Cited by 273
Designing Bioinspired Anti‐Biofouling Surfaces based on a Superwettability Strategy
Zhang, P., Lin, L., Zang, D., Guo, X., & Liu, M. (2017) · Small · doi:10.1002/smll.201503334 · Cited by 266
Kikuchi, A., & Okano, T. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.08.026 · Cited by 264
Plasma Surface Modification of Biomedical Polymers: Influence on Cell-Material Interaction
Jacobs, T., Morent, R., De Geyter, N., Dubruel, P., & Leys, C. (2012) · Plasma Chemistry and Plasma Processing · doi:10.1007/s11090-012-9394-8 · Cited by 255
Surface engineering strategies for control of protein and cell interactions
Nath, N., Hyun, J., Ma, H., & Chilkoti, A. (2004) · Surface Science · doi:10.1016/j.susc.2004.06.182 · Cited by 232
Wu, Y., Simonovsky, F. I., Ratner, B. D., & Horbett, T. A. (2005) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30381 · Cited by 198
Shenoy, D., Little, S., Langer, R., & Amiji, M. (2005) · Molecular Pharmaceutics · doi:10.1021/mp0500420 · Cited by 193
Self-citationDeschamps, A. A., Grijpma, D. W., & Feijen, J. (2001) · Polymer · doi:10.1016/s0032-3861(01)00453-0 · Cited by 176
Otsuka, H., Nagasaki, Y., & Kataoka, K. (2000) · Biomacromolecules · doi:10.1021/bm990005s · Cited by 173
Han, D. K., & Hubbell, J. A. (1997) · Macromolecules · doi:10.1021/ma970302u · Cited by 164
Protein adsorption and cell attachment to patterned surfaces
McFarland, C. D., Thomas, C. H., DeFilippis, C., Steele, J. G., & Healy, K. E. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200002)49:2<200::aid-jbm7>3.0.co;2-l · Cited by 161
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126
Bao, J., Wu, Q., Sun, J., Zhou, Y., Wang, Y., Jiang, X., Li, L., Shi, Y., & Bu, H. (2015) · Scientific Reports · doi:10.1038/srep10756 · Cited by 82
Metadata
- Authors
- Amiji, M., & Park, K.
- Venue
- Journal of Biomaterials Science, Polymer Edition
- Publisher
- Informa UK Limited
- Published
- 1993-01
- Volume
- 4
- Issue
- 3
- Pages
- 217-234
- ISSN
- 0920-5063 (ISSN-L)
- 1568-5624
- OpenAlex
- W1989010574
- Cited by
- 346
- References
- 53
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.