The DOI matches its Crossref record.
Detection of expiratory flow limitation during mechanical ventilation.
Abstract
Two new methods, application of negative pressure at the airway opening during expiration (NEP) and reduction of flow resistance by bypassing the expiratory line of the ventilator by exhaling into the atmosphere (ATM), were used to detect expiratory flow limitation in 12 semirecumbent (45 degree) mechanically ventilated patients, seven with chronic airway obstruction (CAO). An increase of expiratory flow with NEP or ATM, relative to the preceding control breath, was taken as indicating absence of expiratory flow limitation. By contrast, the portion of the tidal expiration over which there was no change in flow with NEP or ATM was considered as flow-limited. With NEP, nine patients exhibited flow limitation, six (all with CAO) were flow-limited over most of the tidal expiration (> 70% VT), and three at < 60% VT. Although the results with NEP and ATM were in general in good agreement, in the three non-flow-limited patients the ATM method gave erroneous results. Six patients were also studied supine, including two who were not flow-limited when semirecumbent: both became flow-limited when supine. We conclude that NEP provides a simple method to detect flow limitation in mechanically ventilated patients. The supine position enhances flow limitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diaz, O., Villafranca, C., Ghezzo, H., Borzone, G., Leiva, A., Milic-Emil, J., & Lisboa, C. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16b14.x · Cited by 300
Eltayara, L., Becklake, M. R., Volta, C. A., & Milic-Emili, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.6.8970362 · Cited by 277
Self-citationFlow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
Self-citationRespiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
Metadata
- Authors
- Valta, P., Corbeil, C., Lavoie, A., Campodonico, R., Koulouris, N., Chassé, M., Braidy, J., & Milic-Emili, J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-11
- Volume
- 150
- Issue
- 5
- Pages
- 1311-1317
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2085689684
- Cited by
- 171
- References
- 0
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of expiratory flow limitation during mechanical ventilation. https://app.cochat.ai/papers/10.1164/ajrccm.150.5.7952558
- The paper
- Valta, P., Corbeil, C., Lavoie, A., Campodonico, R., Koulouris, N., Chassé, M., Braidy, J., & Milic-Emili, J. (1994). Detection of expiratory flow limitation during mechanical ventilation. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.150.5.7952558
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.