Detection of expiratory flow limitation during mechanical ventilation.
The DOI matches its Crossref record.
Abstract
Two new methods, application of negative pressure at the airway opening during expiration (NEP) and reduction of flow resistance by bypassing the expiratory line of the ventilator by exhaling into the atmosphere (ATM), were used to detect expiratory flow limitation in 12 semirecumbent (45 degree) mechanically ventilated patients, seven with chronic airway obstruction (CAO). An increase of expiratory flow with NEP or ATM, relative to the preceding control breath, was taken as indicating absence of expiratory flow limitation. By contrast, the portion of the tidal expiration over which there was no change in flow with NEP or ATM was considered as flow-limited. With NEP, nine patients exhibited flow limitation, six (all with CAO) were flow-limited over most of the tidal expiration (> 70% VT), and three at < 60% VT. Although the results with NEP and ATM were in general in good agreement, in the three non-flow-limited patients the ATM method gave erroneous results. Six patients were also studied supine, including two who were not flow-limited when semirecumbent: both became flow-limited when supine. We conclude that NEP provides a simple method to detect flow limitation in mechanically ventilated patients. The supine position enhances flow limitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diaz, O., Villafranca, C., Ghezzo, H., Borzone, G., Leiva, A., Milic-Emil, J., & Lisboa, C. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.16b14.x · Cited by 300
Eltayara, L., Becklake, M. R., Volta, C. A., & Milic-Emili, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.6.8970362 · Cited by 277
Self-citationFlow limitation and dynamic hyperinflation: key concepts in modern respiratory physiology
Calverley, P. M. A., & Koulouris, N. G. (2005) · European Respiratory Journal · doi:10.1183/09031936.04.00113204 · Cited by 258
Self-citationA simple method to detect expiratory flow limitation during spontaneous breathing
Koulouris, N., Valta, P., Lavoie, A., Corbeil, C., Chasse, M., Braidy, J., & Milic-Emili, J. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08020306 · Cited by 251
“The NEP technique for detecting expiratory flow limitation has previously been applied and validated by concomitant determination of isovolume V-P relationships in intensive care unit (ICU) patients during controlled mechanical ventilation [13].”
BackgroundMethodInfluentialSelf-citationRespiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
“One male subject (subject 3) was excluded in the analysis of expiratory flow limitation because the negative expiratory pressure caused a sustained decrease in expiratory flow using previously defined criteria (Valta et al. 1994; Tantucci et al. 1999).”
BackgroundMethodInfluentialExpiratory flow limitation and intrinsic positive end-expiratory pressure in obesity
Pankow, W., Podszus, T., Gutheil, T., Penzel, T., Peter, J.-H., & Von Wichert, P. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1236 · Cited by 240
“The purpose of the present study was to detect expiratory flow limitation (EFL) in OS with a novel method of using negative expiratory pressure (NEP) (13, 33).”
MethodEffect of salbutamol on dynamic hyperinflation in chronic obstructive pulmonary disease patients
Tantucci, C., Duguet, A., Similowski, T., Zelter, M., Derenne, J., & Milic-Emili, J. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.12040799 · Cited by 216
“EFL was assessed with the negative expiratory pressure (NEP) method [5, 11].”
MethodSelf-citationDetection of expiratory flow limitation during exercise in COPD patients
Koulouris, N. G., Dimopoulou, I., Valta, P., Finkelstein, R., Cosio, M. G., & Milic-Emili, J. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.3.723 · Cited by 161
“In this connection, it should be noted that the flow spikes can be regarded as a characteristic marker of flow limitation (16, 30).”
BackgroundMethodInfluentialSelf-citationExpiratory Flow Limitation Definition, Mechanisms, Methods, and Significance
Tantucci, C. (2013) · Pulmonary Medicine · doi:10.1155/2013/749860 · Cited by 60
Physiological consequences of a high work of breathing during heavy exercise in humans
Guenette, J. A., & Sheel, A. W. (2007) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2007.02.003 · Cited by 54
Metadata
- Authors
- Valta, P., Corbeil, C., Lavoie, A., Campodonico, R., Koulouris, N., Chassé, M., Braidy, J., & Milic-Emili, J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-11
- Volume
- 150
- Issue
- 5
- Pages
- 1311-1317
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2085689684
- Cited by
- 171
- References
- 0
- FWCI
- 8.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.