CoChat

Expiratory muscle activity increases intrinsic positive end-expiratory pressure independently of dynamic hyperinflation in mechanically ventilated patients.

Lessard, M R, Lofaso, F, Brochard, L · 1995 · American Journal of Respiratory and Critical Care Medicine
Cited by 204

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Intrinsic positive end-expiratory pressure (PEEPi) has usually been interpreted as suggesting dynamic hyperinflation, but expiratory muscle activity may also increase end-expiratory alveolar pressure without any additional increase in end-expiratory lung volume. The aim of this study was to assess the influence of expiratory muscle activity, which increases abdominal pressure during expiration and is followed by a sudden drop at end-expiration, on PEEPi measurement in mechanically ventilated patients. We studied eight tracheally intubated patients breathing in an assisted mode in whom expiratory muscle activity was present. PEEPi was measured from the fluctuations of esophageal pressure (Pes) while continuous recording of gastric pressure (Pga) and of changes in abdominal cross-sectional area assessed expiratory muscle activity. PEEPi was also measured by the airway occlusion method in one patient, and diaphragmatic electromyographic activity was recorded to determine the timing of inspiratory muscle activity in two patients. Varying the level of ventilatory support (pressure support level, peak flow rate, or PEEP level) induced increases in measured PEEPi from 6.7 +/- 3.4 to 13.2 +/- 5.9 cm H2O. Concomitantly, the expiratory rise in Pga increased from 3.1 +/- 2.7 to 8.6 +/- 5.0 cm H2O, and the abrupt decay in Pga observed at the end of expiration increased from 4.2 +/- 3.7 to 10.6 +/- 6.1 cm H2O. The drop in Pga and the drop in Pes at end-expiration were synchronous, and these changes, together with electromyographic measurements, were consistent with a concomitant relaxation of the expiratory muscles and activation of the inspiratory muscles.(ABSTRACT TRUNCATED AT 250 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.151.2.7842221

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Metadata

Authors
Lessard, M. R., Lofaso, F., & Brochard, L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1995-02
Volume
151
Issue
2
Pages
562-569
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2058635092
Cited by
204
References
12
FWCI
11.35
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.