Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 192

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome.

Teschler, H, Berthon-Jones, M, Thompson, A B, Henkel, A, Henry, J, Konietzko, N · 1996 · American Journal of Respiratory and Critical Care Medicine

Abstract

This study tested the effectiveness of the AutoSet self-titrating nasal continuous positive airway pressure (nCPAP) system in treating obstructive sleep apnea (OSA), and choosing a suitable pressure for subsequent conventional fixed-pressure nCPAP therapy. Twenty-one adult men with untreated OSA were studied with full polysomnography on each of four nights: diagnostic, manual and AutoSet nCPAP titration (in random order), and conventional fixed-pressure nCPAP at the pressure recommended by the AutoSet titration. Titration was satisfactorily performed in 20 of 21 subjects. Severe mask leak prevented automated titration in one subject and caused transient unnecessary increases in pressure in three subjects. In the 20 subjects, respiratory disturbance index (RDI) was 60.3 +/- 5.7 events/h (mean +/- SEM) on the diagnostic night. RDI was lower with manual titration (10.1 +/- 3.0, p < 0.001), and lower still with Autoset (2.8 +/- 0.9, p < 0.01) and fixed pressure (2.5 +/- 0.7, p = ns versus AutoSet) nCPAP. There were similar changes in the arousal index, which was 52.7 +/- 4.6 events/h on the diagnostic night, 14.2 +/- 2.4 with manual titration and 8.9 +/- 0.9 with AutoSet titration, and 9.5 +/- 1.0 on the night of conventional fixed-pressure CPAP (p < 0.001 versus diagnostic). We conclude that the AutoSet system is suitable for automated nCPAP pressure titration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.154.3.8810613

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 192

Metadata

Authors
Teschler, H., Berthon-Jones, M., Thompson, A. B., Henkel, A., Henry, J., & Konietzko, N.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1996-09
Volume
154
Issue
3
Pages
734-740
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W1981565421
Cited by
192
References
3
FWCI
5.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome. https://app.cochat.ai/papers/10.1164/ajrccm.154.3.8810613
The paper
Teschler, H., Berthon-Jones, M., Thompson, A. B., Henkel, A., Henry, J., & Konietzko, N. (1996). Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.154.3.8810613

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.