The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome.
Abstract
This study tested the effectiveness of the AutoSet self-titrating nasal continuous positive airway pressure (nCPAP) system in treating obstructive sleep apnea (OSA), and choosing a suitable pressure for subsequent conventional fixed-pressure nCPAP therapy. Twenty-one adult men with untreated OSA were studied with full polysomnography on each of four nights: diagnostic, manual and AutoSet nCPAP titration (in random order), and conventional fixed-pressure nCPAP at the pressure recommended by the AutoSet titration. Titration was satisfactorily performed in 20 of 21 subjects. Severe mask leak prevented automated titration in one subject and caused transient unnecessary increases in pressure in three subjects. In the 20 subjects, respiratory disturbance index (RDI) was 60.3 +/- 5.7 events/h (mean +/- SEM) on the diagnostic night. RDI was lower with manual titration (10.1 +/- 3.0, p < 0.001), and lower still with Autoset (2.8 +/- 0.9, p < 0.01) and fixed pressure (2.5 +/- 0.7, p = ns versus AutoSet) nCPAP. There were similar changes in the arousal index, which was 52.7 +/- 4.6 events/h on the diagnostic night, 14.2 +/- 2.4 with manual titration and 8.9 +/- 0.9 with AutoSet titration, and 9.5 +/- 1.0 on the night of conventional fixed-pressure CPAP (p < 0.001 versus diagnostic). We conclude that the AutoSet system is suitable for automated nCPAP pressure titration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Self-citationMaxillofacial Surgery and Nasal CPAP
Riley, R. W., Powell, N. B., & Guilleminault, C. (1990) · Chest · doi:10.1378/chest.98.6.1421 · Cited by 146
CPAP Titration for Sleep Apnea Using a Split-Night Protocol
Yamashiro, Y., & Kryger, M. H. (1995) · Chest · doi:10.1378/chest.107.1.62 · Cited by 104
Cited by
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
IP, M. S. M., LAM, B., CHAN, L.-Y., ZHENG, L., TSANG, K. W. T., FUNG, P. C. W., & LAM, W.-K. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.6.2002126 · Cited by 478
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Masa, J. F., Jiménez, A., Durán, J., Capote, F., Monasterio, C., Mayos, M., Terán, J., Hernández, L., Barbé, F., Maimó, A., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200312-1787oc · Cited by 328
Cardiovascular and metabolic effects of CPAP in obese males with OSA
Coughlin, S. R., Mawdsley, L., Mugarza, J. A., Wilding, J. P. H., & Calverley, P. M. A. (2007) · European Respiratory Journal · doi:10.1183/09031936.00043306 · Cited by 315
Metadata
- Authors
- Teschler, H., Berthon-Jones, M., Thompson, A. B., Henkel, A., Henry, J., & Konietzko, N.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-09
- Volume
- 154
- Issue
- 3
- Pages
- 734-740
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1981565421
- Cited by
- 192
- References
- 3
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome. https://app.cochat.ai/papers/10.1164/ajrccm.154.3.8810613
- The paper
- Teschler, H., Berthon-Jones, M., Thompson, A. B., Henkel, A., Henry, J., & Konietzko, N. (1996). Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.154.3.8810613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.