Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome.
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
This study tested the effectiveness of the AutoSet self-titrating nasal continuous positive airway pressure (nCPAP) system in treating obstructive sleep apnea (OSA), and choosing a suitable pressure for subsequent conventional fixed-pressure nCPAP therapy. Twenty-one adult men with untreated OSA were studied with full polysomnography on each of four nights: diagnostic, manual and AutoSet nCPAP titration (in random order), and conventional fixed-pressure nCPAP at the pressure recommended by the AutoSet titration. Titration was satisfactorily performed in 20 of 21 subjects. Severe mask leak prevented automated titration in one subject and caused transient unnecessary increases in pressure in three subjects. In the 20 subjects, respiratory disturbance index (RDI) was 60.3 +/- 5.7 events/h (mean +/- SEM) on the diagnostic night. RDI was lower with manual titration (10.1 +/- 3.0, p < 0.001), and lower still with Autoset (2.8 +/- 0.9, p < 0.01) and fixed pressure (2.5 +/- 0.7, p = ns versus AutoSet) nCPAP. There were similar changes in the arousal index, which was 52.7 +/- 4.6 events/h on the diagnostic night, 14.2 +/- 2.4 with manual titration and 8.9 +/- 0.9 with AutoSet titration, and 9.5 +/- 1.0 on the night of conventional fixed-pressure CPAP (p < 0.001 versus diagnostic). We conclude that the AutoSet system is suitable for automated nCPAP pressure titration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles and Practice of Sleep Medicine
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-59875-3 · Cited by 5,088
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731
Self-citationHoffstein, V., Viner, S., Mateika, S., & Conway, J. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/145.4_pt_1.841 · Cited by 317
Condos, R., Norman, R. G., Krishnasamy, I., Peduzzi, N., Goldring, R. M., & Rapoport, D. M. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.2.8049832 · Cited by 241
Nino‐Murcia, G., McCann, C. C., Bliwise, D. L., Guilleminault, C., & Dement, W. C. (1989) · PubMed Central · Cited by 147
Maxillofacial Surgery and Nasal CPAP
Riley, R. W., Powell, N. B., & Guilleminault, C. (1990) · Chest · doi:10.1378/chest.98.6.1421 · Cited by 146
Upper airway closing pressures in snorers
Issa, F. G., & Sullivan, C. E. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.2.528 · Cited by 143
CPAP Titration for Sleep Apnea Using a Split-Night Protocol
Yamashiro, Y., & Kryger, M. H. (1995) · Chest · doi:10.1378/chest.107.1.62 · Cited by 104
Predicting nasal continuous positive airway pressure.
Hoffstein, V, & Mateika, S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.2.8049834 · Cited by 93
TREATMENT OF OBSTRUCTIVE SLEEP-APNEA WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE
Stradling (1983) · Thorax · Cited by 90
Cited by
Task Force Members, Kushida, C. A., Chediak, A., Berry, R. B., Brown, L. K., Gozal, D., Iber, C., Parthasarathy, S., Quan, S. F., & Rowley, J. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27133 · Cited by 749
IP, M. S. M., LAM, B., CHAN, L.-Y., ZHENG, L., TSANG, K. W. T., FUNG, P. C. W., & LAM, W.-K. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.6.2002126 · Cited by 478
Mulgrew, A. T., Fox, N., Ayas, N. T., & Ryan, C. F. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-3-200702060-00004 · Cited by 368
“Together with the ResMed Autoscan software, this device is capable of storing and downloading data on compliance; mask leak; and CPAP, including the 95th percentile pressure (29)—the pressure at or below which the patient spent 95% of the time.”
MethodAlternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study
Masa, J. F., Jiménez, A., Durán, J., Capote, F., Monasterio, C., Mayos, M., Terán, J., Hernández, L., Barbé, F., Maimó, A., et al. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200312-1787oc · Cited by 328
Cardiovascular and metabolic effects of CPAP in obese males with OSA
Coughlin, S. R., Mawdsley, L., Mugarza, J. A., Wilding, J. P. H., & Calverley, P. M. A. (2007) · European Respiratory Journal · doi:10.1183/09031936.00043306 · Cited by 315
Positive Airway Pressure Treatment for Obstructive Sleep Apnea
Kakkar, R. K., & Berry, R. B. (2007) · Chest · doi:10.1378/chest.06-2432 · Cited by 258
Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200201-022oc · Cited by 177
Woodson, B. T., Steward, D. L., Weaver, E. M., & Javaheri, S. (2003) · Otolaryngology–Head and Neck Surgery · doi:10.1016/s0194-59980300461-3 · Cited by 165
“PSG parameters to levels comparable to in-laboratory titrations.(16) Titration was performed over”
MethodPelletier-Fleury, N., Rakotonanahary, D., & Fleury, B. (2001) · Sleep Medicine · doi:10.1016/s1389-9457(00)00063-0 · Cited by 162
Treatment of obstructive sleep apnoea with nasal continuous positive airway pressure in stroke
Wessendorf, T. E., Wang, Y.-;., Thilmann, A. F., Sorgenfrei, U., Konietzko, N., & Teschler, H. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00057201 · Cited by 161
“CPAP titration was performed under full polysomnographical control in the sleep laboratory with the AutoSet1 (ResMed, Sydney, Australia), as described elsewhere [17].”
MethodSelf-citationEffect of gender on the development of hypocapnic apnea/hypopnea during NREM sleep
Zhou, X. S., Shahabuddin, S., Zahn, B. R., Babcock, M. A., & Badr, M. S. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.192 · Cited by 147
Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2006168 · Cited by 143
Hui, D. S. C., Chan, J. K. W., Choy, D. K. L., Ko, F. W. S., Li, T. S. T., Leung, R. C. C., & Lai, C. K. W. (2000) · Chest · doi:10.1378/chest.117.5.1410 · Cited by 141
Massie, C. A., & Hart, R. W. (2003) · Chest · doi:10.1378/chest.123.4.1112 · Cited by 131
Patruno, V., Aiolfi, S., Costantino, G., Murgia, R., Selmi, C., Malliani, A., & Montano, N. (2007) · Chest · doi:10.1378/chest.06-2192 · Cited by 130
Constant vs Automatic Continuous Positive Airway Pressure Therapy
d'Ortho, M.-P., Grillier-Lanoir, V., Levy, P., Goldenberg, F., Corriger, E., Harf, A., & Lofaso, F. (2000) · Chest · doi:10.1378/chest.118.4.1010 · Cited by 103
Two months auto-adjusting versus conventional nCPAP for obstructive sleep apnoea syndrome
Teschler, H., Wessendorf, T. E., Farhat, A. A., Konietzko, N., & Berthon-Jones, M. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.01503.x · Cited by 97
Self-citationPositive Pressure Therapy: A Perspective on Evidence-based Outcomes and Methods of Application
Sanders, M. H., Montserrat, J. M., Farré, R., & Givelber, R. J. (2008) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200709-150mg · Cited by 75
Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-542oc · Cited by 73
Dellweg, D., Kerl, J., Hoehn, E., Wenzel, M., & Koehler, D. (2013) · Sleep · doi:10.5665/sleep.2878 · Cited by 64
Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome
Meurice, J. C., Cornette, A., Philip-Joet, F., Pepin, J. L., Escourrou, P., Ingrand, P., & Veale, D. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.019 · Cited by 52
Galetke, W., Anduleit, N., Richter, K., Stieglitz, S., & Randerath, W. J. (2008) · Respiration · doi:10.1159/000097767 · Cited by 49
TO, K. W., CHAN, W. C., CHOO, K. L., LAM, W. K., WONG, K. K., & HUI, D. S. (2008) · Respirology · doi:10.1111/j.1440-1843.2007.01138.x · Cited by 42
Preference for fixed or automatic CPAP in patients with obstructive sleep apnea syndrome
MARRONE, O. (2004) · Sleep Medicine · doi:10.1016/j.sleep.2003.09.011 · Cited by 41
“Several studies have demonstrated that the high pressure levels briefly administered by autoCPAP during the night do not disrupt sleep [24–27].”
BackgroundBureau, M. P. (2000) · Thorax · doi:10.1136/thorax.55.9.741 · Cited by 23
Effects of fixed compared to automatic CPAP on sleep in Obstructive Sleep Apnoea Syndrome
Resta, O., Carratù, P., Depalo, A., Giliberti, T., Ardito, M., Marrone, O., & Insalaco, G. (2004) · Monaldi Archives for Chest Disease · doi:10.4081/monaldi.2004.694 · Cited by 23
“Automatic CPAP ventilators administer a mean level of positive pressure during one night lower than fixed level CPAP machines [6, 7].”
Background
Metadata
- Authors
- Teschler, H., Berthon-Jones, M., Thompson, A. B., Henkel, A., Henry, J., & Konietzko, N.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-09
- Volume
- 154
- Issue
- 3
- Pages
- 734-740
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1981565421
- Cited by
- 192
- References
- 15
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.