Ultrasound evaluation of the paralyzed diaphragm.
The DOI matches its Crossref record.
Abstract
Ultrasound has been used to evaluate diaphragm thickness in the zone of apposition of the diaphragm to the rib cage. The purpose of this study was to determine if ultrasonography could distinguish between a paralyzed and normally functioning diaphragm. We predicted that a paralyzed diaphragm would be atrophic and not shorten, therefore it would be thin and not thicken during inspiration. Thirty subjects (five with bilateral diaphragm paralysis, seven with unilateral diaphragm paralysis, three with inspiratory weakness but normally functioning diaphragms, and 15 healthy control subjects) had diaphragm ultrasound performed with a 7.5 to 10.0 MHz transducer placed over the lower rib cage in the mid-axillary line. The thickness of the diaphragm (tdi) was measured to the nearest 0.1 mm at FRC (t(di)FRC) and TLC (t(di)TLC). Diaphragm thickening during inspiration (delta t(di)) was calculated as (t(di)TLC - t(di)FRC)/t(di)FRC. In patients with unilateral paralysis, t(di) and delta t(di) for the paralyzed hemidiaphragm were significantly less than those values for the normally functioning hemidiaphragm (1.7 +/- 0.2 mm versus 2.7 +/- 0.5 mm [mean + SD] p < 0.01 for t(di), and -8.5 +/- 13% versus 65 +/- 26% [p < 0.001] for delta t(di)). The t(di) and delta t(di) for patients with bilateral diaphragm paralysis were significantly less than those values for the healthy volunteers (1.8 +/- 0.2 versus 2.8 +/- 0.4 and -1 +/- 15% versus 37 +/- 9% for t(di) and delta t(di), respectively) (p < 0.001). We conclude that ultrasound measurements of t(di) and delta t(di) can be used to determine if a diaphragm is paralyzed and confirm our predictions that a chronically paralyzed diaphragm is atrophic and does not thicken during inspiration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Diaphragmatic Motion Studied by M-Mode Ultrasonography
Boussuges, A., Gole, Y., & Blanc, P. (2009) · Chest · doi:10.1378/chest.08-1541 · Cited by 760
Disorders of the Respiratory Muscles
Laghi, F., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2206020 · Cited by 687
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Matamis, D., Soilemezi, E., Tsagourias, M., Akoumianaki, E., Dimassi, S., Boroli, F., Richard, J.-C. M., & Brochard, L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2823-1 · Cited by 576
McCool, F. D., & Tzelepis, G. E. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1007236 · Cited by 489
Self-citationDiaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2014) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 487
Self-citationGoligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Sebastien-Bolz, S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3687-3 · Cited by 448
Diaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation
Vivier, E., Mekontso Dessap, A., Dimassi, S., Vargas, F., Lyazidi, A., Thille, A. W., & Brochard, L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2547-7 · Cited by 406
Critical illness-associated diaphragm weakness
Dres, M., Goligher, E. C., Heunks, L. M. A., & Brochard, L. J. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4928-4 · Cited by 402
Zambon, M., Greco, M., Bocchino, S., Cabrini, L., Beccaria, P. F., & Zangrillo, A. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4524-z · Cited by 386
Neuromuscular ultrasound for evaluation of the diaphragm
Sarwal, A., Walker, F. O., & Cartwright, M. S. (2013) · Muscle & Nerve · doi:10.1002/mus.23671 · Cited by 350
Jung, B., Moury, P. H., Mahul, M., de Jong, A., Galia, F., Prades, A., Albaladejo, P., Chanques, G., Molinari, N., & Jaber, S. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4125-2 · Cited by 330
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Ultrasonographic evaluation of diaphragmatic motion.
Gerscovich, E. O., Cronan, M., McGahan, J. P., Jain, K., Jones, C. D., & McDonald, C. (2001) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2001.20.6.597 · Cited by 312
Tuinman, P. R., Jonkman, A. H., Dres, M., Shi, Z.-H., Goligher, E. C., Goffi, A., de Korte, C., Demoule, A., & Heunks, L. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05892-8 · Cited by 292
Monitoring Recovery From Diaphragm Paralysis With Ultrasound
Summerhill, E. M., El-Sameed, Y. A., Glidden, T. J., & McCool, F. D. (2008) · Chest · doi:10.1378/chest.07-2200 · Cited by 254
Self-citationUltrasonographic Diagnostic Criterion for Severe Diaphragmatic Dysfunction After Cardiac Surgery
Lerolle, N., Guérot, E., Dimassi, S., Zegdi, R., Faisy, C., Fagon, J.-Y., & Diehl, J.-L. (2009) · Chest · doi:10.1378/chest.08-1531 · Cited by 238
Diaphragm Dysfunction: Diagnostic Approaches and Management Strategies
Dubé, B.-P., & Dres, M. (2016) · Journal of Clinical Medicine · doi:10.3390/jcm5120113 · Cited by 230
Ricoy, J., Rodríguez-Núñez, N., Álvarez-Dobaño, J. M., Toubes, M. E., Riveiro, V., & Valdés, L. (2019) · Pulmonology · doi:10.1016/j.pulmoe.2018.10.008 · Cited by 228
Dubé, B.-P., Dres, M., Mayaux, J., Demiri, S., Similowski, T., & Demoule, A. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209459 · Cited by 216
Diagnostic methods to assess inspiratory and expiratory muscle strength
Caruso, P., Albuquerque, A. L. P. D., Santana, P. V., Cardenas, L. Z., Ferreira, J. G., Prina, E., Trevizan, P. F., Pereira, M. C., Iamonti, V., Pletsch, R., et al. (2015) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132015000004474 · Cited by 179
Farghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
Sarwal, A., Parry, S. M., Berry, M. J., Hsu, F.-C., Lewis, M. T., Justus, N. W., Morris, P. E., Denehy, L., Berney, S., Dhar, S., et al. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.7.1191 · Cited by 158
A wearable echomyography system based on a single transducer
Gao, X., Chen, X., Lin, M., Yue, W., Hu, H., Qin, S., Zhang, F., Lou, Z., Yin, L., Huang, H., et al. (2024) · Nature Electronics · doi:10.1038/s41928-024-01271-4 · Cited by 95
“This is widely used in the clinic to evaluate diaphragm dysfunction 34,35 and to predict the success of mechanical ventilation 32,36 .”
Metadata
- Authors
- Gottesman, E., & McCool, F. D.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-05
- Volume
- 155
- Issue
- 5
- Pages
- 1570-1574
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2147763236
- Cited by
- 353
- References
- 0
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.