A wearable echomyography system based on a single transducer
Open accessAbstract
Wearable electromyography devices can detect muscular activity for health monitoring and body motion tracking, but this approach is limited by weak and stochastic signals with a low spatial resolution. Alternatively, echomyography can detect muscle movement using ultrasound waves, but typically relies on complex transducer arrays, which are bulky, have high power consumption and can limit user mobility. Here we report a fully integrated wearable echomyography system that consists of a customized single transducer, a wireless circuit for data processing and an on-board battery for power. The system can be attached to the skin and provides accurate long-term wireless monitoring of muscles. To illustrate its capabilities, we use this system to detect the activity of the diaphragm, which allows the recognition of different breathing modes. We also develop a deep learning algorithm to correlate the single-transducer radio-frequency data from forearm muscles with hand gestures to accurately and continuously track 13 hand joints with a mean error of only 7.9°.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ultrasound signals can serve as a key intermediate variable between the muscle and joint levels for decoding movement intent, as validated in joint angle and torque estimation.
“Furthermore, since muscle morphology often precedes and constrains joint movement, ultrasound signals can serve as a key intermediate variable between the muscle and joint levels for decoding movement intent, as validated in joint angle 118-120 and torque estimation [120][121][122] .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [118]
Acoustic sensors analyze ultrasound echoes to track muscle morphological dynamics and infer joint movement, and are used for muscle morphology monitoring, joint angle estimation, and torque estimation.
“Analyze ultrasound echoes to track muscle | morphological dynamics and infer joint | movement 214 .”
From Recent advances in intelligent wearable systems: from multiscale biomechanical features towards human motion intent prediction (2026) · cites this paper as [118]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Donaldson, G. C. (2002) · Thorax · doi:10.1136/thorax.57.10.847 · Cited by 2,249 · see citing works
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,636 · see citing works
Musculoskeletal ultrasound including definitions for ultrasonographic pathology.
Wakefield, R. J., Balint, P. V., Szkudlarek, M., et al. (2005) · PubMed · Cited by 1,283 · see citing works
Monitoring of the central blood pressure waveform via a conformal ultrasonic device
Wang, C., Li, X., Hu, H., Zhang, L., Huang, Z., Lin, M., Zhang, Z., Yin, Z., Huang, B., Gong, H., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0287-x · Cited by 895 · see citing works
Self-citationMechanical Ventilation–induced Diaphragm Atrophy Strongly Impacts Clinical Outcomes
Goligher, E. C., Dres, M., Fan, E., Rubenfeld, G. D., Scales, D. C., Herridge, M. S., Vorona, S., Sklar, M. C., Rittayamai, N., Lanys, A., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0536oc · Cited by 825 · see citing works
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Côté‐Allard, U., Fall, C. L., Drouin, A., Campeau‐Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. J. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 770 · see citing works
A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N. A. D., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 685 · see citing works
Yu, Y., Nassar, J., Xu, C., Min, J., Yang, Y., Dai, A., Doshi, R., Huang, A., Song, Y., Gehlhar, R., et al. (2020) · Science Robotics · doi:10.1126/scirobotics.aaz7946 · Cited by 655 · see citing works
A wearable cardiac ultrasound imager
Hu, H., Huang, H., Li, M., Gao, X., Yin, L., Qi, R., Wu, R. S., Chen, X., Ma, Y., Shi, K., et al. (2023) · Nature · doi:10.1038/s41586-022-05498-z · Cited by 644 · see citing works
Self-citationZhang, L., Kumar, K. S., He, H., Cai, C. J., He, X., Gao, H., Yue, S., Li, C., Seet, R. C.-S., Ren, H., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18503-8 · Cited by 574 · see citing works
Outcomes of extubation failure in medical intensive care unit patients*
Thille, A. W., Harrois, A., Schortgen, F., Brun‐Buisson, C., & Brochard, L. J. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182282a5a · Cited by 541 · see citing works
McCool, F. D., & Tzelepis, G. E. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1007236 · Cited by 501 · see citing works
Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E. K., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2013) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 490 · see citing works
Liu, Y., Norton, J. J. S., Qazi, R., Zou, Z., Ammann, K. R., Liu, H., Yan, L., Tran, P. L., Jang, K.-I., Lee, J. W., et al. (2016) · Science Advances · doi:10.1126/sciadv.1601185 · Cited by 397 · see citing works
Ershad, F., Thukral, A., Yue, J., Comeaux, P., Lu, Y., Shim, H., Sim, K., Kim, N., Rao, Z., Guevara, R., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17619-1 · Cited by 370 · see citing works
Self-citationAll-printed soft human-machine interface for robotic physicochemical sensing
Yu, Y., Li, J., Solomon, S. A., Min, J., Tu, J., Guo, W. H., Xu, C., Song, Y., & Gao, W. F. (2022) · Science Robotics · doi:10.1126/scirobotics.abn0495 · Cited by 367 · see citing works
Self-citationUltrasound Evaluation of the Paralyzed Diaphragm
Gottesman, E., & McCool, F. D. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.5.9154859 · Cited by 352 · see citing works
Tuinman, P. R., Jonkman, A. H., Dres, M., Shi, Z., Goligher, E. C., Goffi, A., de Korte, C. L., Demoule, A., & Heunks, L. M. A. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05892-8 · Cited by 293 · see citing works
Continuous monitoring of deep-tissue haemodynamics with stretchable ultrasonic phased arrays
Wang, C., Qi, B., Lin, M., Zhang, Z., Makihata, M., Liu, B., Zhou, S., Huang, Y.-H., Hu, H., Gu, Y., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00763-4 · Cited by 274 · see citing works
Self-citationMonitoring Recovery From Diaphragm Paralysis With Ultrasound
Summerhill, E. M., El‐Sameed, Y. A., Glidden, T. J., & McCool, F. D. (2008) · CHEST Journal · doi:10.1378/chest.07-2200 · Cited by 253 · see citing works
Sconfienza, L. M., Albano, D., Allen, G., et al. (2018) · European Radiology · doi:10.1007/s00330-018-5474-3 · Cited by 242 · see citing works
A Review on Electromyography Decoding and Pattern Recognition for Human-Machine Interaction
Simao, M. A., Mendes, N., Gibaru, O., & Neto, P. (2019) · IEEE Access · doi:10.1109/access.2019.2906584 · Cited by 234 · see citing works
Meditation therapy for anxiety disorders
Krisanaprakornkit, T., Sriraj, W., Piyavhatkul, N., & Laopaiboon, M. (2006) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd004998.pub2 · Cited by 232 · see citing works
Sleep-related breathing disorders and cardiovascular disease
Roux, F., D’Ambrosio, C. M., & Mohsenin, V. (2000) · The American Journal of Medicine · doi:10.1016/s0002-9343(00)00302-8 · Cited by 203 · see citing works
Flexible Doppler ultrasound device for the monitoring of blood flow velocity
Wang, F., Jin, P., Feng, Y., Fu, J. S., Wang, P., Liu, X., Zhang, Y., Ma, Y., Yang, Y., Yang, A., et al. (2021) · Science Advances · doi:10.1126/sciadv.abi9283 · Cited by 192 · see citing works
Sweat-activated biocompatible batteries for epidermal electronic and microfluidic systems
Bandodkar, A. J., Lee, S. P., Huang, I. A., Li, W., Wang, S., Su, C.-J., Jeang, W. J., Hang, T., Mehta, S., Nyberg, N., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-0443-7 · Cited by 183 · see citing works
Zheng, Y., Chan, M. M. F., Shi, J., Chen, X., & Huang, Q. H. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.07.012 · Cited by 181 · see citing works
Self-citationA substrate-less nanomesh receptor with meta-learning for rapid hand task recognition
Kim, K. K., Kim, M., Pyun, K. R., Kim, J., Min, J., Koh, S., Root, S. E., Kim, J., Nguyen, B. T., Nishio, Y., et al. (2022) · Nature Electronics · doi:10.1038/s41928-022-00888-7 · Cited by 178 · see citing works
Compliance With Peak Expiratory Flow Monitoring in Home Management of Asthma
Côté, J., Cartier, A., Malo, J., et al. (1998) · CHEST Journal · doi:10.1378/chest.113.4.968 · Cited by 148 · see citing works
Dries, D. J., McGonigal, M. D., Malian, M. S., Bor, B. J., & Sullivan, C. (2004) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/01.ta.0000124462.61495.45 · Cited by 147 · see citing works
Stretchable ultrasonic arrays for the three-dimensional mapping of the modulus of deep tissue
Hu, H., Ma, Y., Gao, X., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01038-w · Cited by 146 · see citing works
Self-citationA photoacoustic patch for three-dimensional imaging of hemoglobin and core temperature
Gao, X., Chen, X., Hu, H., Wang, X., Yue, W., Mu, J., Lou, Z., Zhang, R., Shi, K., Chen, X., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-35455-3 · Cited by 142 · see citing works
Self-citationDiaphragm electromyography using an oesophageal catheter: current concepts
Luo, Y. M., Moxham, J., & Polkey, M. I. (2008) · Clinical Science · doi:10.1042/cs20070348 · Cited by 135 · see citing works
Solnik, S., DeVita, P., Rider, P. M., Long, B. L., & Hortobágyi, T. (2008) · PubMed · Cited by 135 · see citing works
Barnes, P. J. (2019) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2019.105598 · Cited by 101 · see citing works
Airway remodelling in COPD : It's not asthma!
Jones, R. L., Noble, P. B., Elliot, J., & James, A. L. (2016) · Respirology · doi:10.1111/resp.12841 · Cited by 99 · see citing works
Pirompanich, P., & Romsaiyut, S. (2018) · Journal of Intensive Care · doi:10.1186/s40560-018-0277-9 · Cited by 97 · see citing works
Psychophysiological Effects of Breathing Instructions for Stress Management
Conrad, A., Müller, A., Doberenz, S., Kim, S., Meuret, A. E., Wollburg, E., & Roth, W. T. (2007) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-007-9034-x · Cited by 94 · see citing works
Dhawan, A. S., Mukherjee, B., Patwardhan, S., Akhlaghi, N., Diao, G., Levay, G., Holley, R., Joiner, W. M., Harris-Love, M., & Sikdar, S. (2019) · Scientific Reports · doi:10.1038/s41598-019-45459-7 · Cited by 90 · see citing works
NeuroPose: 3D Hand Pose Tracking using EMG Wearables
Liu, Y., Zhang, S., & Gowda, M. (2021) · International World Wide Web Conference (WWW) · doi:10.1145/3442381.3449890 · Cited by 82 · see citing works
Guarracino, F., Vetrugno, L., Forfori, F., Corradi, F., Orso, D., Bertini, P., Ortalda, A., Federici, N., Copetti, R., & Bove, T. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.06.013 · Cited by 74 · see citing works
Calculation of ultrasonic transducer signal-to-noise ratios using the KLM model
Oakley, C. G. (1997) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.655627 · Cited by 66 · see citing works
Simultaneous Prediction of Wrist/Hand Motion via Wearable Ultrasound Sensing
Yang, X., Yan, J., Fang, Y., et al. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2977908 · Cited by 60 · see citing works
Self-citationSurface electromyography signal denoising via EEMD and improved wavelet thresholds
Sun, Z., Xi, X., Yuan, C., Yang, Y., & Hua, X. (2020) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2020359 · Cited by 56 · see citing works
Xue, X., Zhang, B., Moon, S., Xu, G., Huang, C., Sharma, N., & Jiang, X. (2023) · Biosensors · doi:10.3390/bios13010134 · Cited by 49 · see citing works
Li, S., Chen, Z., & Yan, W. (2021) · BMC Pulmonary Medicine · doi:10.1186/s12890-021-01605-4 · Cited by 48 · see citing works
AlMohimeed, I., & Ono, Y. (2020) · Sensors · doi:10.3390/s20133616 · Cited by 46 · see citing works
Sample Sizes for Clinical Trials
Julious, S. A. (2023) · Chapman & Hall/CRC eBooks · doi:10.1201/9780429503658 · Cited by 44 · see citing works
Respiratory Pathophysiology of Panic Disorder: An Ambulatory Monitoring Study
Pfaltz, M. C., Michael, T., Grossman, P., Jens Blechert, A., & Wilhelm, F. H. (2009) · Psychosomatic Medicine · doi:10.1097/psy.0b013e3181b492ff · Cited by 39 · see citing works
Investigating the spatial resolution of EMG and MMG based on a systemic multi-scale model
Klotz, T., Gizzi, L., & Röhrle, O. (2022) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-022-01572-7 · Cited by 35 · see citing works
Phasic and Tonic Coupling between EEG and EMG Demonstrated with Independent Component Analysis
McKeown, M. J., & Radtke, R. A. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200101000-00009 · Cited by 33 · see citing works
Ortenzi, V., Tarantino, S., Castellini, C., et al. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281166 · Cited by 25 · see citing works
Home Monitoring in Asthma Self-Management
Kotses, H., Harver, A., & Humphries, C. T. (2006) · Journal of Asthma · doi:10.1080/02770900600701309 · Cited by 20 · see citing works
Wang, Z., Fang, Y., Zhou, D., et al. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.11.005 · Cited by 18 · see citing works
Diaphragm depth in normal subjects
Shahgholi, L., Baria, M. R., Sorenson, E. J., et al. (2013) · Muscle & Nerve · doi:10.1002/mus.23953 · Cited by 17 · see citing works
Pallotti, A., Orengo, G., & Saggio, G. (2021) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2021.03.003 · Cited by 17 · see citing works
Eskes, M., Balm, A. J. M., van Alphen, M. J. A., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-17790-4 · Cited by 4 · see citing works
Flagged first, then by citations
Research works printed but not linked: 2
- [55]DiNino E, Gartman EJ, Sethi JM & McCool FD Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation. Thorax 69, 423– 427 (2014). 24365607
- [58]Jensen JA Field: a program for simulating ultrasound systems. In 10th Nordic-Baltic Conference on Biomedical Imaging 351– 353 (Citeseer, 1996).
Cited by
Sorted by citations
Design and applications of conductive polymers in wearable electrophysiological sensing
Zhou, N., Zhang, L., Cui, T., Wu, P., & Lei, Z. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3114-6 · Cited by 9 · see citing works
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9 · see citing works
- Authors
- Gao, X., Chen, X., Lin, M., Yue, W., Hu, H., Qin, S., Zhang, F., Lou, Z., Yin, L., Huang, H., Zhou, S., Bian, Y., Yang, X., Zhu, Y., Mu, J., Wang, X., Park, G., Lu, C., Wang, R., Wu, R. S., Wang, J., Li, J., & Xu, S.
- Affiliations
- University of California San Diego (US)
- Terasaki Foundation (US)
- Corresponding author
- Xu, Sheng
- ORCID
- Venue
- Nature Electronics
- Published
- 2024-10-31
- Volume
- 7
- Issue
- 11
- Pages
- 1035-1046
- ISSN
- 2520-1131 (ISSN-L)
- PMC
- PMC12269893
- OpenAlex
- W4403948534
- Cited by
- 95
- References
- 57
- Citations by year
- 2026: 53 · 2025: 41 · 2024: 1
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- Locations
- Nature Electronics (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Foundation for the National Institutes of Health (1R21EB027303-01A1, 3R21EB027303-02S1, 1R01EB033464-01)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- single transducer, diaphragm activity, forearm muscles, hand gesture tracking, wireless health monitoring, body motion tracking, deep learning
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review