Extubation Outcome after Spontaneous Breathing Trials with T-Tube or Pressure Support Ventilation
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
A 2-h T-tube trial of spontaneous breathing was used in selecting patients ready for extubation and discontinuation of mechanical ventilation. However, some doubt remains as to whether it is the most appropriate method of performing a spontaneous breathing trial. We carried out a prospective, randomized, multicenter study involving patients who had received mechanical ventilation for more than 48 h and who were considered by their physicians to be ready for weaning according to clinical criteria and standard weaning parameters. Patients were randomly assigned to undergo a 2-h trial of spontaneous breathing in one of two ways: with a T-tube system or with pressure support ventilation of 7 cm H2O. If a patient had signs of poor tolerance at any time during the trial, mechanical ventilation was reinstituted. Patients without these features at the end of the trial were extubated. Of the 246 patients assigned to the T-tube group, 192 successfully completed the trial and were extubated; 36 of them required reintubation. Of the 238 patients in the group receiving pressure support ventilation, 205 were extubated and 38 of them required reintubation. The percentage of patients who remained extubated after 48 h was not different between the two groups (63% T-tube, 70% pressure support ventilation, p = 0.14). The percentage of patients falling the trial was significantly higher when the T-tube was used (22 versus 14%, p = 0.03). Clinical evolution during the trial was not different in patients reintubated and successfully extubated. ICU mortality among reintubated patients was significantly higher than in successfully extubated patients (27 versus 2.6%, p < 0.001). Spontaneous breathing trials with pressure support or T-tube are suitable methods for successful discontinuation of ventilator support in patients without problems to resume spontaneous breathing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773 · cited 1×
“On admission to the intensive care unit, the patients had a median score of 36 (25th–75th percentiles: 27 to 47) on the Simplified Acute Physiology Score (SAPS II) (10).”
MethodAnalysis of serial measurements in medical research.
Matthews, J. N., Altman, D. G., Campbell, M. J., & Royston, P. (1990) · BMJ · doi:10.1136/bmj.300.6719.230 · Cited by 3,136
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Self-citationYang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Brochard, L., Rauss, A., Benito, S., Conti, G., Mancebo, J., Rekik, N., Gasparetto, A., & Lemaire, F. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.4.7921460 · Cited by 1,122
Brochard, L., Harf, A., Lorino, H., & Lemaire, F. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.2.513 · Cited by 630
Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation
Lemaire, F., Teboul, J.-L., Cinotti, L., Giotto, G., Abrouk, F., Steg, G., Macquin-Mavier, I., & Zapol, W. M. (1988) · Anesthesiology · doi:10.1097/00000542-198808000-00004 · Cited by 570
Respiratory Function during Pressure Support Ventilation
MacIntyre, N. R. (1986) · Chest · doi:10.1378/chest.89.5.677 · Cited by 415
Brochard, L., Rua, F., Lorino, H., Lemaire, F., & Harf, A. (1991) · Anesthesiology · doi:10.1097/00000542-199111000-00004 · Cited by 348
(1987) · Journal of Critical Care · doi:10.1016/0883-9441(87)90022-0 · Cited by 335
Airway Occlusion Pressure and Breathing Pattern as Predictors of Weaning Outcome
Sassoon, C. S. H., & Mahutte, C. K. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.4_pt_1.860 · Cited by 167
Effect of short-term sleep loss on breathing
Cooper, K. R., & Phillips, B. A. (1982) · Journal of Applied Physiology · doi:10.1152/jappl.1982.53.4.855 · Cited by 125
Work of Breathing After Extubation
Ishaaya, A. M., Nathan, S. D., & Belman, M. J. (1995) · CHEST Journal · doi:10.1378/chest.107.1.204 · Cited by 105
Gandía, F., & Blanco, J. (1992) · Intensive Care Medicine · doi:10.1007/bf01694360 · Cited by 89
Self-citation
Cited by
Surviving Sepsis Campaign: International Guidelines for Management of Severe Sepsis and Septic Shock
Dellinger, R. P., Levy, M. M., Rhodes, A., Annane, D., Gerlach, H., Opal, S. M., Sevransky, J. E., Sprung, C. L., Douglas, I. S., Jaeschke, R., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827e83af · Cited by 9,694
Dellinger, R. P., Levy, M. M., Carlet, J. M., Bion, J., Parker, M. M., Jaeschke, R., Reinhart, K., Angus, D. C., Brun-Buisson, C., Beale, R., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-007-0934-2 · Cited by 6,772
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2210-z · Cited by 3,321
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000117317.18092.e4 · Cited by 3,018
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Metadata
- Authors
- ESTEBAN, A., ALÍA, I., GORDO, F., FERNÁNDEZ, R., SOLSONA, J. F., VALLVERDÚ, I., MACÍAS, S., ALLEGUE, J. M., BLANCO, J., CARRIEDO, D., LEÓN, M., de la CAL, M. A., TABOADA, F., de VELASCO, J. G., PALAZÓN, E., CARRIZOSA, F., TOMÁS, R., SUAREZ, J., & GOLDWASSER, R. S.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-08-01
- Volume
- 156
- Issue
- 2
- Pages
- 459-465
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2076081817
- Cited by
- 795
- References
- 14
- FWCI
- 16.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.