The DOI matches its Crossref record.
Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation
Open accessAbstract
The authors studied the hemodynamic effects of rapidly weaning from mechanical ventilation (MV) 15 patients with severe chronic obstructive pulmonary disease (COPD) and cardiovascular disease who were recovering from acute cardiopulmonary decompensation. In each patient, 10 min of spontaneous ventilation (SV) with supplemental oxygen resulted in reducing the mean esophageal pressure (X +/- SD, + 5 +/- 3 to -2 +/- 2.5 mmHg, P less than .01) and increasing cardiac index (CI) 3.2 +/- 0.9 to 4.3 +/- 1.3 1/min/M2, P less than .001), systemic blood pressure (BP 77 +/- 12 to 90 +/- 11 mmHg, P less than .001), heart rate (HR 97 +/- 12 to 112 +/- 16 beats/min, P less than .001), and, most importantly, transmural pulmonary artery occlusion pressure markedly increased (PAOPtm 8 +/- 5 to 25 +/- 13 mmHg, P less than .001), mandating a reinstitution of MV. In four patients with left ventricular (LV) catheters, the PAOP correlated with the LV end-diastolic pressure during both MV and SV. Gated blood pool imaging showed SV increased the LV end-diastolic volume index (65 +/- 24 to 83 +/- 32/M2, P less than .002) with LV ejection fraction unchanged. Patients were treated for a mean of 10 days with diuretics, resulting in a reduction of blood volume (4.55 +/- 0.9 1 to 3.56 +/- 0.55 1) and body weight (-5 kg, P less than .001). Subsequently, nine of the 15 patients were weaned successfully from mechanical ventilation with unchanged PAOP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Evidence-Based Guidelines for Weaning and Discontinuing Ventilatory Support
MacIntyre, N. R. (2001) · Chest · doi:10.1378/chest.120.6_suppl.375s · Cited by 1,240
Extubation Outcome after Spontaneous Breathing Trials with T-Tube or Pressure Support Ventilation
ESTEBAN, A., ALÍA, I., GORDO, F., FERNÁNDEZ, R., SOLSONA, J. F., VALLVERDÚ, I., MACÍAS, S., ALLEGUE, J. M., BLANCO, J., CARRIEDO, D., et al. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9610109 · Cited by 795
The Application of Esophageal Pressure Measurement in Patients with Respiratory Failure
Akoumianaki, E., Maggiore, S. M., Valenza, F., Bellani, G., Jubran, A., Loring, S. H., Pelosi, P., Talmor, D., Grasso, S., Chiumello, D., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201312-2193ci · Cited by 635
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
Metadata
- Authors
- Lemaire, F., Teboul, J.-L., Cinotti, L., Giotto, G., Abrouk, F., Steg, G., Macquin-Mavier, I., & Zapol, W. M.
- Venue
- Anesthesiology
- Published
- 1988-08-01
- Volume
- 69
- Issue
- 2
- Pages
- 171-179
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2142912657
- Cited by
- 570
- References
- 0
- FWCI
- 14.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation. https://app.cochat.ai/papers/10.1097/00000542-198808000-00004
- The paper
- Lemaire, F., Teboul, J.-L., Cinotti, L., Giotto, G., Abrouk, F., Steg, G., Macquin-Mavier, I., & Zapol, W. M. (1988). Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical Ventilation. Anesthesiology. https://doi.org/10.1097/00000542-198808000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.