Spontaneous Breathing During Ventilatory Support Improves Ventilation–Perfusion Distributions in Patients with Acute Respiratory Distress Syndrome
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Ventilation-perfusion (V A/Q) distributions were evaluated in 24 patients with acute respiratory distress syndrome (ARDS), during airway pressure release ventilation (APRV) with and without spontaneous breathing, or during pressure support ventilation (PSV). Whereas PSV provides mechanical assistance of each inspiration, APRV allows unrestricted spontaneous breathing throughout the mechanical ventilation. Patients were randomly assigned to receive APRV and PSV with equal airway pressure limits (Paw) (n = 12) or minute ventilation (V E) (n = 12). In both groups spontaneous breathing during APRV was associated with increases (p < 0.05) in right ventricular end-diastolic volume, stroke volume, cardiac index (CI), PaO2, oxygen delivery, and mixed venous oxygen tension (PvO2) and with reductions (p < 0.05) in pulmonary vascular resistance and oxygen extraction. PSV did not consistently improve CI and PaO2 when compared with APRV without spontaneous breathing. Improved V A/Q matching during spontaneous breathing with APRV was evidenced by decreases in intrapulmonary shunt (equal Paw: 33 +/- 4 to 24 +/- 4%; equal V E: 32 +/- 4 to 25 +/- 2%) (p < 0.05), dead space (equal Paw: 44 +/- 9 to 38 +/- 6%; equal V E: 44 +/- 9 to 38 +/- 6%) (p < 0.05), and the dispersions of ventilation (equal Paw: 0.96 +/- 0.23 to 0.78 +/- 0.22; equal V E: 0.92 +/- 0.23 to 0.79 +/- 0.22) (p < 0.05), and pulmonary blood flow distribution (equal Paw: 0.89 +/- 0.12 to 0.72 +/- 0.10; equal V E: 0.94 +/- 0.19 to 0.78 +/- 0.22) (p < 0.05). PSV did not improve V A/Q distributions when compared with APRV without spontaneous breathing. These findings indicate that uncoupling of spontaneous and mechanical ventilation during APRV improves V A/Q matching in ARDS presumably by recruiting nonventilated lung units. Apparently, mechanical assistance of each inspiration during PSV is not sufficient to counteract the V A/Q maldistribution caused by alveolar collapse in patients with ARDS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Controlled Sedation with Alphaxalone-Alphadolone
Ramsay, M. A. E., Savege, T. M., Simpson, B. R. J., & Goodwin, R. (1974) · BMJ · doi:10.1136/bmj.2.5920.656 · Cited by 2,861
A simplified acute physiology score for ICU patients
GALL, J.-R. L., LOIRAT, P., ALPEROVITCH, A., GLASER, P., GRANTHIL, C., MATHIEU, D., MERCIER, P., THOMAS, R., & VILLERS, D. (1984) · Critical Care Medicine · doi:10.1097/00003246-198411000-00012 · Cited by 1,251
Prognosis in Acute Organ-System Failure
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Annals of Surgery · doi:10.1097/00000658-198512000-00004 · Cited by 1,225
A simple method for assessing the validity of the esophageal balloon technique.
Baydur, A., BEHRAKIS, P. K., Zin, W. A., Jaeger, M., & Milic‐Emili, J. (1982) · PubMed · doi:10.1164/arrd.1982.126.5.788 · Cited by 1,076
Effects of Anesthesia and Paralysis on Diaphragmatic Mechanics in Man
Froese, A. B., & Bryan, A. C. (1974) · Anesthesiology · doi:10.1097/00000542-197409000-00006 · Cited by 789
Brochard, L., Harf, A., Lorino, H., & Lemaire, F. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/139.2.513 · Cited by 630
Amato, M. B., Barbas, C. S., Medeiros, D. M., Schettino, G. D. P., Lorenzi Filho, G., Kairalla, R. A., Deheinzelin, D., Morais, C., Fernandes, E. D. O., & Takagaki, T. Y. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.152.6.8520744 · Cited by 625
Lung Structure and Function in Different Stages of Severe Adult Respiratory Distress Syndrome
Gattinoni, L. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03510460064035 · Cited by 589
Petrof, B. J., Legaré, M., Goldberg, P., Milic-Emili, J., & Gottfried, S. B. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/141.2.281 · Cited by 486
Wagner, P. D., Laravuso, R. B., Uhi, R. R., & West, J. B. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107750 · Cited by 479
Simultaneous measurement of eight foreign gases in blood by gas chromatography
Wagner, P. D., Naumann, P. F., & Laravuso, R. B. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.36.5.600 · Cited by 360
Ventilation-perfusion distributions in the adult respiratory distress syndrome.
Dantzker, D. R., Brook, C. J., DeHart, P. D., Lynch, J. P., & Weg, J. G. (1979) · PubMed · doi:10.1164/arrd.1979.120.5.1039 · Cited by 349
Dantzker, D. R., Lynch, J. P., & Weg, J. G. (1980) · Chest · doi:10.1378/chest.77.5.636 · Cited by 285
Determinants of pulmonary arterial flow variation during respiration
Pinsky, M. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.5.1237 · Cited by 173
Putensen, C., Rasanen, J. O., & López, F. A. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.1.8025733 · Cited by 139
Self-citationBeydon, L., Cinotti, L., Rekik, N., Radermacher, P., Adnot, S., Meignan, M. A., HARF, A., & Lemaire, F. (1991) · Anesthesiology · doi:10.1097/00000542-199111000-00003 · Cited by 34
Cited by
Acute respiratory distress syndrome
Matthay, M. A., Zemans, R. L., Zimmerman, G. A., Arabi, Y. M., Beitler, J. R., Mercat, A., Herridge, M., Randolph, A. G., & Calfee, C. S. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-019-0069-0 · Cited by 2,387
Acute respiratory distress syndrome
Meyer, N. J., Gattinoni, L., & Calfee, C. S. (2021) · The Lancet · doi:10.1016/s0140-6736(21)00439-6 · Cited by 1,144
PUTENSEN, C., ZECH, S., WRIGGE, H., ZINSERLING, J., STÜBER, F., VON SPIEGEL, T., & MUTZ, N. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.164.1.2001078 · Cited by 638
Self-citationOther approaches to open-lung ventilation: Airway pressure release ventilation
Habashi, N. M. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155920.11893.37 · Cited by 309
Scaravilli, V., Grasselli, G., Castagna, L., Zanella, A., Isgrò, S., Lucchini, A., Patroniti, N., Bellani, G., & Pesenti, A. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.07.008 · Cited by 281
Metadata
- Authors
- PUTENSEN, C., MUTZ, N. J., PUTENSEN-HIMMER, G., & ZINSERLING, J.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-04-01
- Volume
- 159
- Issue
- 4
- Pages
- 1241-1248
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2013033345
- Cited by
- 435
- References
- 17
- FWCI
- 15.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.