Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 315

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Optoelectronic Plethysmography in Intensive Care Patients

ALIVERTI, ANDREA, DELLACÁ, RAFFAELE, PELOSI, PAOLO, CHIUMELLO, DAVIDE, PEDOTTI, ANTONIO, GATTINONI, LUCIANO · 2000 · American Journal of Respiratory and Critical Care Medicine

Abstract

We used optoelectronic plethysmography to study 11 normal subjects during quiet and deep breathing, six sedated and paralyzed patients with acute lung injury and acute respiratory distress syndrome (ALI/ARDS) receiving continuous positive pressure ventilation (CPPV) (positive end-expiratory pressure [PEEP] = 10 cm H(2)O, tidal volume [VT] = 300, 600, 900 ml), and seven ALI/ARDS patients receiving pressure support ventilation (PSV) (PEEP 10 cm H(2)O, pressure support = 5, 10, 15, 25 cm H(2)O). The volumes measured using optoelectronic plethysmography were compared with measurements taken using spirometry and pneumotachography. The three methods were highly correlated. The discrepancies found were 1.7 +/- 5.9%, -1.6 +/- 5.4%, and 4.9 +/- 6.4% when comparing optoelectronic plethysmography with spirometry, optoelectronic plethysmography with pneumotachography, and spirometry with pneumotachography, respectively. Accuracy of the compartmentalization procedure (upper thorax, lower thorax, and abdomen) was assessed by calculating compartmental volume changes during isovolume maneuvers. The discrepancy from the ideal zero line was -2.1 +/- 48.3 ml. Abdominal contribution to inspired volume was greater for normal subjects than for PSV patients (63 +/- 11% versus 43 +/- 14%, p < 0.001). It decreased with VT for normal subjects (48.5 +/- 15%, p < 0.05), whereas it increased for CPPV patients (61 +/- 10%, p < 0.05). No significant distribution differences were found between 5 and 25 cm H(2)O PSV. We conclude that optoelectronic plethysmography is a feasible technique able to provide unique data on the distribution of chest wall volume changes in intensive care patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1164/ajrccm.161.5.9903024

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 315

Metadata

Authors
ALIVERTI, A., DELLACÁ, R., PELOSI, P., CHIUMELLO, D., PEDOTTI, A., & GATTINONI, L.
Venue
American Journal of Respiratory and Critical Care Medicine
Published
2000-05-01
Volume
161
Issue
5
Pages
1546-1552
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2001646069
Cited by
315
References
12
FWCI
50.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optoelectronic Plethysmography in Intensive Care Patients. https://app.cochat.ai/papers/10.1164/ajrccm.161.5.9903024
The paper
ALIVERTI, A., DELLACÁ, R., PELOSI, P., CHIUMELLO, D., PEDOTTI, A., & GATTINONI, L. (2000). Optoelectronic Plethysmography in Intensive Care Patients. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.161.5.9903024

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.