Predictors of Successful Extubation in Neurosurgical Patients
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
A respiratory therapist-driven weaning protocol incorporating daily screens, spontaneous breathing trials (SBT), and prompts to caregivers has been associated with superior outcomes in mechanically ventilated medical patients. To determine the effectiveness of this approach in neurosurgical (NSY) patients, we conducted a randomized controlled trial involving 100 patients over a 14-mo period. All had daily screens of weaning parameters. If these were passed, a 2-h SBT was performed in the Intervention group. Study physicians communicated positive SBT results, and the decision to extubate was made by the primary NSY team. Patients in the Intervention (n = 49) and Control (n = 51) groups had similar demographic characteristics, illness severity, and neurologic injuries. Among all patients, 87 (45 in the Control and 42 in the Intervention group) passed at least one daily screen. Forty (82%) patients in the Intervention group passed SBT, but a median of 2 d passed before attempted extubation, primarily because of concerns about the patient's sensorium (84%). Of 167 successful SBT, 126 (75%) did not lead to attempted extubation on the same day. The median time of mechanical ventilation was 6 d in both study groups, and there were no differences in outcomes. Overall complications included death (36%), reintubation (16%), and pneumonia (9%). Tracheostomies were created in 29% of patients. Multivariate analysis showed that Glasgow Coma Scale (GCS) score (p < 0.0001) and partial pressure of arterial oxygen/fraction of inspired oxygen ratio (p < 0.0001) were associated with extubation success. The odds of successful extubation increased by 39% with each GCS score increment. A GCS score > or = 8 at extubation was associated with success in 75% of cases, versus 33% for a GCS score < 8 (p < 0.0001). Implementation of a weaning protocol based on traditional respiratory physiologic parameters had practical limitations in NSY patients, owing to concerns about neurologic impairment. Whether protocols combining respiratory parameters with neurologic measures lead to superior outcomes in this population requires further investigation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
ASSESSMENT OF COMA AND IMPAIRED CONSCIOUSNESS
Teasdale, G., & Jennett, B. (1974) · The Lancet · doi:10.1016/s0140-6736(74)91639-0 · Cited by 13,215
CDC definitions for nosocomial infections, 1988
Garner, J. S., Jarvis, W. R., Emori, T. G., Horan, T. C., & Hughes, J. M. (1988) · American Journal of Infection Control · doi:10.1016/0196-6553(88)90053-3 · Cited by 5,672
CDC definitions for nosocomial infections
Yangco, B. G. (1989) · American Journal of Infection Control · doi:10.1016/s0196-6553(89)80013-6 · Cited by 3,770
An Expanded Definition of the Adult Respiratory Distress Syndrome
Murray, J. F., Matthay, M. A., Luce, J. M., & Flick, M. R. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.3.720 · Cited by 2,646
An Introduction to Medical Statistics.
(1931) · Journal of the American Medical Association · doi:10.1001/jama.1931.02730150055037 · Cited by 2,084
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Yang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Cited by
Ely, E. W., Inouye, S. K., Bernard, G. R., Gordon, S., Francis, J., May, L., Truman, B., Speroff, T., Gautam, S., Margolin, R., et al. (2001) · JAMA · doi:10.1001/jama.286.21.2703 · Cited by 3,210
“65 28 100 (86-100) 100 (85-100) 100 (16-100) 83 (16-100)”
Self-citationWeaning from mechanical ventilation
Boles, J.-M., Bion, J., Connors, A., Herridge, M., Marsh, B., Melot, C., Pearl, R., Silverman, H., Stanchina, M., Vieillard-Baron, A., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00010206 · Cited by 2,064
Evolution of Mechanical Ventilation in Response to Clinical Research
Esteban, A., Ferguson, N. D., Meade, M. O., Frutos-Vivar, F., Apezteguia, C., Brochard, L., Raymondos, K., Nin, N., Hurtado, J., Tomicic, V., et al. (2008) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200706-893oc · Cited by 725
Delirium in the intensive care unit
Girard, T. D., Pandharipande, P. P., & Ely, E. W. (2008) · Critical Care · doi:10.1186/cc6149 · Cited by 622
The Decision to Extubate in the Intensive Care Unit
Thille, A. W., Richard, J.-C. M., & Brochard, L. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201208-1523ci · Cited by 576
The ABCDEF Bundle: Science and Philosophy of How ICU Liberation Serves Patients and Families
Ely, E. W. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002175 · Cited by 514
Self-citationBTS/ICS guideline for the ventilatory management of acute hypercapnic respiratory failure in adults
Davidson, A. C., Banham, S., Elliott, M., Kennedy, D., Gelder, C., Glossop, A., Church, A. C., Creagh-Brown, B., Dodd, J. W., Felton, T., et al. (2016) · Thorax · doi:10.1136/thoraxjnl-2015-208209 · Cited by 426
A Multicenter Randomized Trial of Computer-driven Protocolized Weaning from Mechanical Ventilation
Lellouche, F., Mancebo, J., Jolliet, P., Roeseler, J., Schortgen, F., Dojat, M., Cabello, B., Bouadma, L., Rodriguez, P., Maggiore, S., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200511-1780oc · Cited by 406
Girard, T. D., Alhazzani, W., Kress, J. P., Ouellette, D. R., Schmidt, G. A., Truwit, J. D., Burns, S. M., Epstein, S. K., Esteban, A., Fan, E., et al. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201610-2075st · Cited by 387
Neurologic status, cough, secretions and extubation outcomes
Salam, A., Tilluckdharry, L., Amoateng-Adjepong, Y., & Manthous, C. A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2231-7 · Cited by 349
Blackwood, B., Alderdice, F., Burns, K., Cardwell, C., Lavery, G., & O'Halloran, P. (2011) · BMJ · doi:10.1136/bmj.c7237 · Cited by 336
Mechanical Ventilator Weaning Protocols Driven by Nonphysician Health-Care Professionals
Ely, E. W., Meade, M. O., Haponik, E. F., Kollef, M. H., Cook, D. J., Guyatt, G. H., & Stoller, J. K. (2001) · Chest · doi:10.1378/chest.120.6_suppl.454s · Cited by 288
Self-citationEpstein, S. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1268-8 · Cited by 288
Blackwood, B., Burns, K. E., Cardwell, C. R., & O'Halloran, P. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006904.pub3 · Cited by 285
Weaning Patients from the Ventilator
McConville, J. F., & Kress, J. P. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1203367 · Cited by 270
Ely, E. W., Wheeler, A. P., Thompson, B. T., Ancukiewicz, M., Steinberg, K. P., Bernard, G. R., & for the Acute Respiratory Distress Syndrome Network (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-136-1-200201010-00007 · Cited by 268
Self-citationThille, A. W., Boissier, F., Ben Ghezala, H., Razazi, K., Mekontso-Dessap, A., & Brun-Buisson, C. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000000748 · Cited by 261
Management and outcome of mechanically ventilated neurologic patients*
Pelosi, P., Ferguson, N. D., Frutos-Vivar, F., Anzueto, A., Putensen, C., Raymondos, K., Apezteguia, C., Desmery, P., Hurtado, J., Abroug, F., et al. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31821209a8 · Cited by 257
Extubation failure: magnitude of the problem, impact on outcomes, and prevention
Rothaar, R. C., & Epstein, S. K. (2003) · Current Opinion in Critical Care · doi:10.1097/00075198-200302000-00011 · Cited by 244
Egi, M., Ogura, H., Yatabe, T., Atagi, K., Inoue, S., Iba, T., Kakihana, Y., Kawasaki, T., Kushimoto, S., Kuroda, Y., et al. (2021) · Journal of Intensive Care · doi:10.1186/s40560-021-00555-7 · Cited by 224
Weaning from the ventilator and extubation in ICU
Thille, A. W., Cortés-Puch, I., & Esteban, A. (2013) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32835c5095 · Cited by 205
“Factors that have been associated with extubation failure include age [2 && ,5,9], primary reason for intubation [5,6,9], neurological dysfunction [6,44,45], cough efficacy [46,47] and amount of secretions [27,45,47] (Table 2).”
BackgroundNavalesi, P., Frigerio, P., Moretti, M. P., Sommariva, M., Vesconi, S., Baiardi, P., & Levati, A. (2008) · Critical Care Medicine · doi:10.1097/ccm.0b013e31818b35f2 · Cited by 188
“the primary end points were duration of mechanical ventilation, length of ICU stay (8), and time to successful extubation, we powered our study on the rate of reintubation secondary to extubation failure.”
BackgroundMethodResultInfluentialIMPACT OF NOSOCOMIAL INFECTIOUS COMPLICATIONS AFTER SUBARACHNOID HEMORRHAGE
Frontera, J. A., Fernandez, A., Schmidt, J. M., Claassen, J., Wartenberg, K. E., Badjatia, N., Parra, A., Connolly, E. S., & Mayer, S. A. (2008) · Neurosurgery · doi:10.1227/01.neu.0000311064.18368.ea · Cited by 175
“Candidates for early tracheostomy can be identified by using a variety of validated criteria (42, 46).”
BackgroundClinical review: Respiratory monitoring in the ICU - a consensus of 16
Brochard, L., Martin, G. S., Blanch, L., Pelosi, P., Belda, F. J., Jubran, A., Gattinoni, L., Mancebo, J., Ranieri, V. M., Richard, J.-C. M., et al. (2012) · Critical Care · doi:10.1186/cc11146 · Cited by 160
“conscious ness, typical weaning and liberation techniques used in medical-surgical ICU patients may not apply to this group [109,112].”
MethodNi, Y.-N., Luo, J., Yu, H., Liu, D., Liang, B.-M., & Liang, Z.-A. (2018) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2017.07.083 · Cited by 112
“However, respiratory failure often results from the initial disease whichusually has been solved in the patients after extubation,while patients after surgery or extubation needs respiratory support mainly because of low cough strength and level of consciousness [47-48], which would weaken the advantages of HFNC.”
BackgroundVidotto, M. C., Sogame, L. C. M., Calciolari, C. C., Nascimento, O. A., & Jardim, J. R. (2008) · Neurocritical Care · doi:10.1007/s12028-008-9059-x · Cited by 47
“In addition we found an incidence of 16% of reintubation, in agreement with another study with similar population [ 8 ].”
BackgroundResultInfluentialOtaguro, T., Tanaka, H., Igarashi, Y., Tagami, T., Masuno, T., Yokobori, S., Matsumoto, H., Ohwada, H., & Yokota, H. (2021) · Journal of Nippon Medical School · doi:10.1272/jnms.jnms.2021_88-508 · Cited by 41
Metadata
- Authors
- NAMEN, A. M., WESLEY ELY, E., TATTER, S. B., DOUGLAS CASE, L., LUCIA, M. A., SMITH, A., LANDRY, S., WILSON, J. A., GLAZIER, S. S., BRANCH, C. L., KELLY, D. L., BOWTON, D. L., & HAPONIK, E. F.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-03-01
- Volume
- 163
- Issue
- 3
- Pages
- 658-664
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2099586690
- Cited by
- 355
- References
- 33
- FWCI
- 9.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.