Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Constant continuous positive airway pressure (CPAP) is the treatment of choice for the obstructive sleep apnea syndrome (OSAS). To enable the pressure to be matched more accurately to actual requirements, and thus increase patient acceptance, an autoadjusting device based on the measurement of upper airway impedance was developed (APAPFOT). We investigated the efficacy and compliance in continuous use at home. Fifty-two patients were treated (randomized crossover) with CPAP and APAPFOT for 6 wk each. Respiratory disturbances, sleep profile, and arousals improved significantly with both modes (AHI: baseline, 35.1 ± 26/h; APAPFOT, 5.0 ± 5.2; CPAP, 4.3 ± 6.3; p < 0.001 baseline versus each mode). The mean pressure with APAPFOT was significantly reduced as compared with CPAP (CPAP, 7.8 ± 1.5 cm H2O; APAPFOT, 5.7 ± 1.8 cm H2O; p < 0.001). Under APAPFOT the pressure was lower than that under CPAP for 81.5 ± 21% of the time. Although overall use did not differ, 75% of the patients preferred APAPFOT for home treatment. We conclude that APAPFOT is as efficacious as constant CPAP in the treatment of OSAS. The treatment pressure can be reduced significantly, and sleep microstructure improved with APAPFOT. These might be the reasons for patient preference of automatic therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the other hand, in one study more discomfort due to pressure variation with APAP was noted.194”
In the citing paper
“A total of 5 studies reported differences in side effects between APAP and CPAP.186,193,194,198,208”
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,637
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 2×
“On the basis of the results of this study, therefore, we conclude that ( 1 ) autoadjusting treatment based on measurement of impedance enables effective treatment of OSAS over 6 wk at home.”
BackgroundOscillation Mechanics of Lungs and Chest in Man
DuBois, A. B., Brody, A. W., Lewis, D. H., & Burgess, B. F. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.8.6.587 · Cited by 814
Condos, R., Norman, R. G., Krishnasamy, I., Peduzzi, N., Goldring, R. M., & Rapoport, D. M. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.2.8049832 · Cited by 241
Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome.
Teschler, H., Berthon-Jones, M., Thompson, A. B., Henkel, A., Henry, J., & Konietzko, N. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.3.8810613 · Cited by 192
Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome.
Meurice, J. C., Marc, I., & Sériès, F. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.2.8564134 · Cited by 177
Angewandte Statistik : statistische Methoden und ihre Anwendungen
Sachs, L. (1978) · Springer eBooks · Cited by 152
Time-course of stepwise CPAP titration. Behavior of respiratory and neurological variables.
Montserrat, J. M., Ballester, E., Olivi, H., Reolid, A., Lloberes, P., Morello, A., & Rodriguez-Roisin, R. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.6.8520746 · Cited by 118
KONERMANN, M., Sanner, B. M., Vyleta, M. S., Laschewski, F., Groetz, J., Sturm, A., & Zidek, W. (1998) · CHEST Journal · doi:10.1378/chest.113.3.714 · Cited by 105
Two months auto-adjusting versus conventional nCPAP for obstructive sleep apnoea syndrome
Teschler, H., Wessendorf, T. E., Farhat, A. A., Konietzko, N., & Berthon-Jones, M. (2000) · European Respiratory Journal · doi:10.1034/j.1399-3003.2000.01503.x · Cited by 97 · cited 3×
“Subjective data on sleep quality, self-assessment, and patients’ preference were not reported by Teschler ( 23 ) or Konermann (24).”
BackgroundInfluentialNavajas, D., Farré, R., Rotger, M., BADIA, R., Puig-de-Morales, M., & Montserrat, J. M. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.5.9710026 · Cited by 89
Teschler, H., Farhat, A., Exner, V, Konietzko, N., & Berthon-Jones, M. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10092073 · Cited by 77
Meurice, J., Paquereau, J., Denjean, A., Patte, F., & Series, F. (1998) · European Respiratory Journal · doi:10.1183/09031936.98.11051121 · Cited by 75
Nasal Continuous Positive Airway Pressure Treatment: Current Realities and Future
Berthon-Jones, M., Lawrence, S., Sullivan, C. E., & Grunstein, R. (1996) · Sleep · doi:10.1093/sleep/19.suppl_9.s131 · Cited by 74
Gugger, M. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10030587 · Cited by 71
Sharma, S., Wali, S., Pouliot, Z., Peters, M., Neufeld, H., & Kryger, M. (1996) · Sleep · doi:10.1093/sleep/19.6.497 · Cited by 69
Fleury, B., Rakotonanahary, D., Hausser-Hauw, C., Lebeau, B., & Guilleminault, C. (1996) · Sleep · doi:10.1093/sleep/19.6.502 · Cited by 59
A system to generate simultaneous forced oscillation and continuous positive airway pressure
Farré, R., Rotger, M., Montserrat, J. M., & Navajas, D. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10061349 · Cited by 59
Inspiratory Dynamic Obstruction Detected by Forced Oscillation During CPAP. A Model Study
Farré, R., Peslin, R., Rotger, M., & Navajas, D. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.3.9117031 · Cited by 58
Badia, J. R., Farré, R., KIMOFF, R. J., Ballester, E., Hernández, L., Rotger, M., Navajas, D., & Montserrat, J. M. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.5.9902085 · Cited by 53 · cited 1×
“According to Badia and colleagues ( 31 ) accurate measurement of impedance and detection of leakage mandate the simultaneous determination of airflow and pressure variations.”
BackgroundAutomatic control of airway pressure for treatment of obstructive sleep apnea
Behbehani, K., Yen, F.-C., Burk, J. R., Lucas, E. A., & Axe, J. R. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.464375 · Cited by 49 · cited 1×
“( 2 ) Under APAPFOT, a significant reduction in treatment pressure is achieved.”
BackgroundSelf-adjusting Nasal Continuous Positive Airway Pressure Therapy Based on Measurement of Impedance
Randerath, W. J., Parys, K., Feldmeyer, F., Sanner, B. M., & ̈hle, K. H. R. (1999) · CHEST Journal · doi:10.1378/chest.116.4.991 · Cited by 47
Self-citationUpper Airway Resistance Syndrome
Rühle, K.-H., Schlenker, E., & Randerath, W. (2009) · Respiration · doi:10.1159/000196733 · Cited by 35
Self-citationTwo months follow up of auto-CPAP treatment in patients with obstructive sleep apnoea
Boudewyns, A., Grillier-Lanoir, V, Willemen, M. J., De Cock, W. A., Van de Heyning, P. H., & De Backer, W. A. (1999) · Thorax · doi:10.1136/thx.54.2.147 · Cited by 32 · cited 1×
“In an open study involving patients pretreated with constant CPAP, Boudewyns and colleagues ( 22 ) discovered a significant improvement in the polysomnographic data with an autoadjusting CPAP system, as had been seen earlier with constant CPAP.”
BackgroundSelf-Adjusting Continuous Positive Airway Pressure Therapy Based on the Measurement of Impedance
Randerath, W. J., Parys, K., Lehmann, D., Sanner, B. M., Feldmeyer, F., & Rühle, K.-H. (2000) · Respiration · doi:10.1159/000029510 · Cited by 21
Self-citationAuto CPAP in the Treatment of Sleep Apnea Hypopnea Syndrome
Sériès, F. (1996) · SLEEP · doi:10.1093/sleep/19.suppl_10.s281 · Cited by 16
[Effect of automatically titrated CPAP systems on sleep and respiration in sleep apnea syndrome].
Hoster, M., Schlenker, E., & Rühle, K.-H. (1996) · PubMed · Cited by 11
Self-citation
Research works printed but not linked: 1
- Hoster, 1996, Influence of automated self-setting CPAP systems on sleep and breathing in sleep apnea syndrome., Wien Med Wochenschr, 146, 385
Cited by
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Morgenthaler, T. I., Aurora, R. N., Brown, T., Zak, R., Alessi, C., Boehlecke, B., Chesson, A. L., Friedman, L., Kapur, V., Maganti, R., et al. (2008) · Sleep · doi:10.1093/sleep/31.1.141 · Cited by 334
Weaver, T. E., & Sawyer, A. M. (2010) · PubMed · Cited by 385
Qaseem, A., Holty, J.-E. C., Owens, D. K., Dallas, P., Starkey, M., & Shekelle, P. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-7-201310010-00704 · Cited by 305
Metadata
- Authors
- RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H.
- Affiliations
- Witten/Herdecke University (DE)
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-03-01
- Volume
- 163
- Issue
- 3
- Pages
- 652-657
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1975723518
- Cited by
- 143
- References
- 28
- Citations by year
- 2025: 3 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 2 · 2017: 6 · 2016: 3 · 2014: 4 · 2013: 4 · 2012: 5
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- auto-titrating CPAP, paracetamol, obstructive sleep apnea, CPAP adherence, patient acceptance, sleep microstructure, arousal
- MeSH terms
- Female, Humans, Male, Middle Aged, Patient Compliance, Positive-Pressure Respiration, Prospective Studies, Electric Impedance, Cross-Over Studies, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.