Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Constant continuous positive airway pressure (CPAP) is the treatment of choice for the obstructive sleep apnea syndrome (OSAS). To enable the pressure to be matched more accurately to actual requirements, and thus increase patient acceptance, an autoadjusting device based on the measurement of upper airway impedance was developed (APAPFOT). We investigated the efficacy and compliance in continuous use at home. Fifty-two patients were treated (randomized crossover) with CPAP and APAPFOT for 6 wk each. Respiratory disturbances, sleep profile, and arousals improved significantly with both modes (AHI: baseline, 35.1 ± 26/h; APAPFOT, 5.0 ± 5.2; CPAP, 4.3 ± 6.3; p < 0.001 baseline versus each mode). The mean pressure with APAPFOT was significantly reduced as compared with CPAP (CPAP, 7.8 ± 1.5 cm H2O; APAPFOT, 5.7 ± 1.8 cm H2O; p < 0.001). Under APAPFOT the pressure was lower than that under CPAP for 81.5 ± 21% of the time. Although overall use did not differ, 75% of the patients preferred APAPFOT for home treatment. We conclude that APAPFOT is as efficacious as constant CPAP in the treatment of OSAS. The treatment pressure can be reduced significantly, and sleep microstructure improved with APAPFOT. These might be the reasons for patient preference of automatic therapy.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the other hand, in one study more discomfort due to pressure variation with APAP was noted.194”
In the citing paper
“A total of 5 studies reported differences in side effects between APAP and CPAP.186,193,194,198,208”
Citations
Cites
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,654
Sullivan, C., Berthon-Jones, M., Issa, F., & Eves, L. (1981) · The Lancet · doi:10.1016/s0140-6736(81)92140-1 · Cited by 2,731 · cited 2×
“On the basis of the results of this study, therefore, we conclude that ( 1 ) autoadjusting treatment based on measurement of impedance enables effective treatment of OSAS over 6 wk at home.”
BackgroundOscillation Mechanics of Lungs and Chest in Man
DuBois, A. B., Brody, A. W., Lewis, D. H., & Burgess, B. F. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.8.6.587 · Cited by 814
Condos, R., Norman, R. G., Krishnasamy, I., Peduzzi, N., Goldring, R. M., & Rapoport, D. M. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.150.2.8049832 · Cited by 241
Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome.
Teschler, H., Berthon-Jones, M., Thompson, A. B., Henkel, A., Henry, J., & Konietzko, N. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.3.8810613 · Cited by 192
Efficacy of auto-CPAP in the treatment of obstructive sleep apnea/hypopnea syndrome.
Meurice, J. C., Marc, I., & Sériès, F. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.153.2.8564134 · Cited by 177
Angewandte Statistik : statistische Methoden und ihre Anwendungen
Sachs, L. (1978) · Springer eBooks · Cited by 152
Time-course of stepwise CPAP titration. Behavior of respiratory and neurological variables.
Montserrat, J. M., Ballester, E., Olivi, H., Reolid, A., Lloberes, P., Morello, A., & Rodriguez-Roisin, R. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.6.8520746 · Cited by 118
KONERMANN, M., Sanner, B. M., Vyleta, M. S., Laschewski, F., Groetz, J., Sturm, A., & Zidek, W. (1998) · CHEST Journal · doi:10.1378/chest.113.3.714 · Cited by 105
Research works printed but not linked: 1
- Hoster, 1996, Influence of automated self-setting CPAP systems on sleep and breathing in sleep apnea syndrome., Wien Med Wochenschr, 146, 385
Cited by
Patil, S. P., Ayappa, I. A., Caples, S. M., Kimoff, R. J., Patel, S. R., & Harrod, C. G. (2019) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7638 · Cited by 721
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
Morgenthaler, T. I., Aurora, R. N., Brown, T., Zak, R., Alessi, C., Boehlecke, B., Chesson, A. L., Friedman, L., Kapur, V., Maganti, R., et al. (2008) · Sleep · doi:10.1093/sleep/31.1.141 · Cited by 334
Weaver, T. E., & Sawyer, A. M. (2010) · PubMed · Cited by 390
Qaseem, A., Holty, J.-E. C., Owens, D. K., Dallas, P., Starkey, M., & Shekelle, P. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-7-201310010-00704 · Cited by 305
Randerath, W. J., Heise, M., Hinz, R., & Ruehle, K.-H. (2002) · Chest · doi:10.1378/chest.122.2.569 · Cited by 257
Self-citationAyas, N. T., Patel, S. R., Malhotra, A., Schulzer, M., Malhotra, M., Jung, D., Fleetham, J., & White, D. P. (2004) · Sleep · doi:10.1093/sleep/27.2.249 · Cited by 255
Sleep apnea: Clinical investigations in humans
Banno, K., & Kryger, M. H. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.003 · Cited by 219
“It has been reported that the reduced mean pressure with APAP compared to fixed pressure CPAP is the reason for patient preference of APAP [256].”
BackgroundLittner, M., Hirshkowitz, M., Davila, D., Anderson, W. M., Kushida, C. A., Woodson, B. T., Johnson, S. F., & Wise, M. S. (2002) · Sleep · doi:10.1093/sleep/25.2.143 · Cited by 183
Comparison between Automatic and Fixed Positive Airway Pressure Therapy in the Home
Massie, C. A., McArdle, N., Hart, R. W., Schmidt-Nowara, W. W., Lankford, A., Hudgel, D. W., Gordon, N., & Douglas, N. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200201-022oc · Cited by 177
Interventions to improve use of continuous positive airway pressure for obstructive sleep apnoea
Smith, I., Lasserson, T. J., & Haniffa, M. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub2 · Cited by 152
Smith, I., & Lasserson, T. J. (2009) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub3 · Cited by 151
Ip, S., D'Ambrosio, C., Patel, K., Obadan, N., Kitsios, G. D., Chung, M., & Balk, E. M. (2012) · Systematic Reviews · doi:10.1186/2046-4053-1-20 · Cited by 148
“Randerath 2001 [26] 11254519 XO 55 87 32.”
BackgroundMethodInfluentialDescription and Validation of the Apnea Risk Evaluation System
Westbrook, P. R., Levendowski, D. J., Cvetinovic, M. M., Zavora, T., Velimirovic, V., Henninger, D., & Nicholson, D. (2005) · CHEST Journal · doi:10.1378/chest.128.4.2166 · Cited by 147
Farré, R., Montserrat, J. M., Rigau, J., Trepat, X., Pinto, P., & Navajas, D. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2111050 · Cited by 106
Randerath, W. J., Galetke, W., Domanski, U., Weitkunat, R., & Ruhle, K.-H. (2004) · Sleep · doi:10.1093/sleep/27.2.254 · Cited by 104
Self-citationAcceptance and long-term compliance of nCPAP in obstructive sleep apnea
Richard, W., Venker, J., den Herder, C., Kox, D., van den Berg, B., Laman, M., van Tinteren, H., & de Vries, N. (2007) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s00405-007-0311-3 · Cited by 123
Pressure-Relief Continuous Positive Airway Pressure vs Constant Continuous Positive Airway Pressure
Nilius, G., Happel, A., Domanski, U., & Ruhle, K.-H. (2006) · Chest · doi:10.1378/chest.130.4.1018 · Cited by 99
Can Patients with Obstructive Sleep Apnea Titrate Their Own Continuous Positive Airway Pressure?
Fitzpatrick, M. F., Alloway, C. E. D., Wakeford, T. M., MacLean, A. W., Munt, P. W., & Day, A. G. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200204-360oc · Cited by 98
Gay, P. C., Herold, D. L., & Olson, E. J. (2003) · Sleep · doi:10.1093/sleep/26.7.864 · Cited by 90
Compliance in sleep apnoea therapy: influence of home care support and pressure mode
Damjanovic, D., Fluck, A., Bremer, H., Müller-Quernheim, J., Idzko, M., & Sorichter, S. (2009) · European Respiratory Journal · doi:10.1183/09031936.00023408 · Cited by 81
Noninvasive detection of expiratory flow limitation in COPD patients during nasal CPAP
Dellacà, R. L., Rotger, M., Aliverti, A., Navajas, D., Pedotti, A., & Farré, R. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00080005 · Cited by 77
“Moreover, as FOT has already been proved to be very well tolerated by patients when combined with noninvasive mechanical ventilation [ 21 , 22], it may be useful to incorporate this measurement into mechanical ventilators able to continuously optimise the PEEP level to changes in patient posture, conditions, lung volu…”
MethodVennelle, M., White, S., Riha, R. L., Mackay, T. W., Engleman, H. M., & Douglas, N. J. (2010) · Sleep · doi:10.1093/sleep/33.2.267 · Cited by 74
Senn, O., Brack, T., Matthews, F., Russi, E. W., & Bloch, K. E. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200304-542oc · Cited by 73
“However, in several studies major outcomes of sleep apnea therapy, i.e., subjective sleepiness, objective vigilance, or cognitive performance, were not improved by autoCPAP compared with fixed-pressure CPAP (10, 11), or these outcomes had not been evaluated (7, 12 ).”
BackgroundRanderath, W. J., Galetke, W., Kenter, M., Richter, K., & Schäfer, T. (2009) · Sleep Medicine · doi:10.1016/j.sleep.2008.09.017 · Cited by 68
“APAP reduces the treatment pressure substantially and is preferred by patients [23–25].”
BackgroundSelf-citationRigau, J., Montserrat, J. M., Wöhrle, H., Plattner, D., Schwaibold, M., Navajas, D., & Farré, R. (2006) · CHEST Journal · doi:10.1378/chest.130.2.350 · Cited by 71
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
“…are normally divided into four different types which are summarized in table 5 and discussed shortly along with their major advantages, features and target patients (Levitt 2001, Randerath et al 2001, Ayas et al 2004, Hukins 2004, Essouri et al 2005, Ho and Wong 2006, Philippe et al 2006).”
BackgroundNussbaumer, Y., Bloch, K. E., Genser, T., & Thurnheer, R. (2006) · Chest · doi:10.1378/chest.129.3.638 · Cited by 63
Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome
Meurice, J. C., Cornette, A., Philip-Joet, F., Pepin, J. L., Escourrou, P., Ingrand, P., & Veale, D. (2007) · Sleep Medicine · doi:10.1016/j.sleep.2007.03.019 · Cited by 52
“More recent devices are able to detect very complex signals mostly reflecting the presence of flow limitation during the inspiratory phase [7,8].”
BackgroundManagement of Obstructive Sleep Apnea-Hypopnea Syndrome: Overview
Phillips, B. A., & Kryger, M. H. (2005) · Elsevier eBooks · doi:10.1016/b0-72-160797-7/50099-9 · Cited by 56
Obstructive sleep apnea symptoms beyond sleepiness and snoring: effects of nasal APAP therapy
Cruz, I. A. C., Drummond, M., & Winck, J. C. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0502-4 · Cited by 50
“Recent studies report that nasal automatic positive airway pressure (APAP) has similar efficacy to CPAP in improving sleep quality and reducing daytime sleepiness, snoring, number of arousals, and apnea–hypopnea index (AHI) [11–16], while it may be more accepted by patients, increasing its compliance [14–16].”
BackgroundSchoch, O. D., Baty, F., Niedermann, J., Rüdiger, J. J., & Brutsche, M. H. (2014) · Respiration · doi:10.1159/000354186 · Cited by 49
Xu, T., Li, T., Wei, D., Feng, Y., Xian, L., Wu, H.-Q., & Xu, J. (2011) · Sleep And Breathing · doi:10.1007/s11325-011-0626-6 · Cited by 59
“[25], this preference was not associated with an increase in treatment adherence.”
BackgroundGaletke, W., Anduleit, N., Richter, K., Stieglitz, S., & Randerath, W. J. (2008) · Respiration · doi:10.1159/000097767 · Cited by 49
“However, although patients more frequently prefer APAP to CPAP in crossover trials, a significant increase in adherence could not be achieved with APAP therapy [”
BackgroundSelf-citationBench testing of auto-adjusting positive airway pressure devices
Abdenbi, F., Chambille, B., & Escourrou, P. (2004) · European Respiratory Journal · doi:10.1183/09031936.04.00133703 · Cited by 49
“Given the wide variety of algorithms used by these devices [ 15-18 ], clinical tests do not allow general conclusions to be derived for particular apparatus that are valid in all patients.”
MethodKennedy, B., Lasserson, T. J., Wozniak, D. R., & Smith, I. (2019) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003531.pub4 · Cited by 47
Treatment of Obstructive Sleep Apnea Syndrome
Freedman, N. S. (2010) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2010.02.012 · Cited by 54
Efficiency of cold passover and heated humidification under continuous positive airway pressure
Randerath, W. J., Meier, J., Genger, H., Domanski, U., & Rühle, K. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00267902 · Cited by 47
Self-citationA Pilot Study Assessing Adherence to Auto-Bilevel Following a Poor Initial Encounter with CPAP
Powell, E. D., Gay, P. C., Ojile, J. M., Litinski, M., & Malhotra, A. (2012) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.1658 · Cited by 46
“However, the vast majority of trials using these devices show no clinically important usage benefi t over standard CPAP therapy, 5-8 despite some preference for the adjustable pressure devices versus standard CPAP.”
Obstructive sleep apnoea in acute coronary syndrome
Randerath, W. J., Bonsignore, M. R., & Herkenrath, S. D. (2019) · European Respiratory Review · doi:10.1183/16000617.0114-2018 · Cited by 53
Self-citationFietze, I., Glos, M., Moebus, I., Witt, C., Penzel, T., & Baumann, G. (2007) · Respiration · doi:10.1159/000100364 · Cited by 45
“explain the residual AHI by postulating an overestimation of hypopneas. We assume that manual upward titration does not cause the residual AHI in the titration night. The number of residual breathing disorders still occurring throughout the night depends on the practical procedures associated with manual titration. We…”
InfluentialContinuous positive airway pressure therapy in sleep apnoea
Hsu, A. A. L., & Lo, C. P. L. (2003) · Respirology · doi:10.1046/j.1440-1843.2003.00494.x · Cited by 48
Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea
Nolan, G. M., Ryan, S., O’Connor, T. M., & McNicholas, W. T. (2006) · European Respiratory Journal · doi:10.1183/09031936.06.00127205 · Cited by 43
Preference for fixed or automatic CPAP in patients with obstructive sleep apnea syndrome
MARRONE, O. (2004) · Sleep Medicine · doi:10.1016/j.sleep.2003.09.011 · Cited by 41
“Among studies directly evaluating the effects of autoCPAP on compliance to treatment, a few showed a positive effect [11–14], while others did not [15–17].”
BackgroundFuchs, F. S., Wiest, G. H., Frank, M., Harsch, I. A., Schahin, S. P., Hahn, E. G., & Ficker, J. H. (2002) · Sleep · doi:10.1093/sleep/25.5.512 · Cited by 39
Hussain, S. F., Love, L., Burt, H., & Fleetham, J. A. (2004) · Respiratory Medicine · doi:10.1016/j.rmed.2003.11.002 · Cited by 37
Efficacy of Flow- vs Impedance-Guided Autoadjustable Continuous Positive Airway Pressure
Pevernagie, D., Proot, P. M., Hertegonne, K. B. C., Neyens, M. C., Hoornaert, K., & PAUWELS, R. A. (2004) · CHEST Journal · doi:10.1378/chest.126.1.25 · Cited by 38
Hertegonne, K. B. C., & Bauters, F. A. (2009) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2009.07.001 · Cited by 35
Reliability of home CPAP titration with different automatic CPAP devices
Sériès, F., Plante, J., & Lacasse, Y. (2008) · Respiratory Research · doi:10.1186/1465-9921-9-56 · Cited by 30
“Different automatic CPAP devices are presently available that differ in the analyzed signals, in the definition of respiratory events, in the signal processing as well as in the algorithm of pressure response [18-24].”
BackgroundPires, F. S., Drummond, M., Marinho, A., Sampaio, R., Pinto, T., Gonçalves, M., Neves, I., Pinto, C. S., Sucena, M., Winck, J. C., et al. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0789-9 · Cited by 32
“However, most authors have reported similar adherence rates for APAP and fixed CPAP [26–29].”
BackgroundComparison of different techniques to measure air leaks during CPAP treatment in neonates
Schmalisch, G., Fischer, H. S., Roehr, C. C., & Proquitté, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.05.002 · Cited by 29
Galetke, W., Ghassemi, B. M., Priegnitz, C., Stieglitz, S., Anduleit, N., Richter, K., & Randerath, W. J. (2014) · Sleep Medicine · doi:10.1016/j.sleep.2014.02.012 · Cited by 25
Self-citationGaletke, W., Randerath, W. J., Stieglitz, S., Laumanns, C., Anduleit, N., Richter, K., & Schäfer, T. (2008) · Sleep Medicine · doi:10.1016/j.sleep.2008.03.007 · Cited by 25
Self-citationContinuous positive airway pressure: new generations
Roux, F., & Hilbert, J. (2003) · Clinics in Chest Medicine · doi:10.1016/s0272-5231(03)00017-0 · Cited by 25
“Patients were more aware of pressure variations when treated with APAP than CPAP in one report [51], felt the pressure was lower on APAP than CPAP in another report [35], and had a tendency to report breathing against the machine more with APAP than CPAP in yet another report [49], but no other differences have been n…”
BackgroundInfluentialEarly objective adherence to hypoglossal nerve stimulation therapy
Huyett, P. A. (2021) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.9688 · Cited by 24
Quantification of Pharyngeal Patency in Patients with Sleep-Disordered Breathing
Vanderveken, O. M., Oostveen, E., Boudewyns, A. N., Verbraecken, J. A., de Heyning, P. V., & Backer, W. A. D. (2005) · ORL · doi:10.1159/000086572 · Cited by 28
Molina, M., Hernández, L., Duran, J., Farré, R., Rubio, R., Navajas, D., & Montserrat, J. M. (2003) · Archivos de Bronconeumología · doi:10.1016/s0300-2896(03)75338-1 · Cited by 21
de Melo, P. L., & Lemes, L. N. D. A. (2002) · Review of Scientific Instruments · doi:10.1063/1.1511793 · Cited by 21
Bakker, J. P., Campbell, A. J., & Neill, A. M. (2010) · Sleep And Breathing · doi:10.1007/s11325-010-0385-9 · Cited by 19
“On the whole, the literature indicates no significant differences between APAP and CPAP in terms of apnoea–hypopnoea index (AHI) reduction [18], sleep architecture [19], sleep efficiency [19], subjective sleepiness [20] or compliance [21]; given that APAP is generally considered to be as effective as CPAP for ongoing…”
BackgroundTreatment of Obstructive Sleep Apnea
Freedman, N. S. (2017) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2017.07.003 · Cited by 19
Obstructive sleep apnea ? management update
Hukins, C. (2006) · Neuropsychiatric Disease and Treatment · doi:10.2147/nedt.2006.2.3.309 · Cited by 24
Lemes, L. N. D. A., & de Melo, P. L. (2002) · Physiological Measurement · doi:10.1088/0967-3334/24/1/302 · Cited by 18
Respiratory System and Artificial Ventilation
Lucangelo, U., Pelosi, P. P., Aliverti, A., & W. A., Z. (2008) · Springer eBooks · doi:10.1007/978-88-470-0765-9 · Cited by 19
Ficker, J. H., Clarenbach, C. F., Neukirchner, C., Fuchs, F. S., Wiest, G., Schahin, S. P., Harsch, I. A., & Hahn, E. G. (2003) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2003.48.3.68 · Cited by 17
Autoadjusting Continuous Positive Airway Pressure
Levy, P. A., & Pépin, J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.6.ed1801f · Cited by 16
Continuous positive airway pressure therapy: new generations.
Garvey, J., & McNicholas, W. T. (2010) · PubMed · Cited by 19
Snoring detection during auto-nasal continuous positive airway pressure
Lofaso, F., Leroux, K., Quera-Salva, M.-A., Mroue, G., d’Ortho, M., Isabey, D., & Louis, B. (2002) · European Respiratory Journal · doi:10.1183/09031936.02.00213302 · Cited by 14
“auto-nasal continuous positive airway pressure devices suggests that further studies are needed to evaluate and compare such devices, particularly the new devices that use detection of flow limitation or those that continuously measure the impedance and/or resistance of the respiratory system using noninvasive means s…”
BackgroundLettieri, C. F., Lettieri, C. J., & Carter, K. (2011) · CHEST Journal · doi:10.1378/chest.10-1060 · Cited by 17
Choi, W., Bae, M. R., & Chung, Y. (2021) · Clinical and Experimental Otorhinolaryngology · doi:10.21053/ceo.2020.02362 · Cited by 15
Auto-adjusting positive airway pressure: the fine line between engineering and medicine
Messineo, L., White, D. P., Hete, B., Knepper, M., Berry, R. B., & Noah, W. H. (2025) · Sleep And Breathing · doi:10.1007/s11325-025-03409-w · Cited by 13
“However, it has to be noted that several other studies have shown no difference in side effects between CPAP and APAP [18, 35, 40, 49 , 53, 56], with additional evidence of reduced comfort with APAP possibly due to the oscillating pressure [52].”
Treatment of Obstructive Sleep Apnea
Freedman, N. S. (2020) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2020.02.007 · Cited by 11
Salgado, S. M. D. S. T., Boléo-Tomé, J. P. C. F., Canhão, C. M. S., Dias, A. R. T., Teixeira, J. I., Pinto, P. M. G., & Caetano, M. C. D. B. E. B. P. (2008) · Jornal Brasileiro de Pneumologia · doi:10.1590/s1806-37132008000900009 · Cited by 9
Sangal, R. B., & Sudan, N. (2019) · Clinical EEG and Neuroscience · doi:10.1177/1550059419892759 · Cited by 9
Howard, J., Lee, S. H., Inusa, B. P. D., Cheng, M. Y. E., Bavenjit, C., Reading, I., Wakeford, S., Gavlak, J., Murphy, P. B., Hart, N., et al. (2019) · Trials · doi:10.1186/s13063-019-3461-x · Cited by 10
“[31] also found that PAP machines improved rapid eye movement (REM) sleep and decreased daytime sleepiness after 6 weeks of use in OSA patients.”
BackgroundTobin, M. J. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2312010 · Cited by 11
Pordzik, J., Ludwig, K., Seifen, C., Ruckes, C., Huppertz, T., Bahr‐Hamm, K., Hackenberg, B., Matthias, C., & Gouveris, H. T. (2024) · Respiratory Medicine · doi:10.1016/j.rmed.2024.107750 · Cited by 9
Bakker, J. P., Campbell, A. J., & Neill, A. M. (2011) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2010.00846.x · Cited by 11
“, 2000), sleep architecture (Konermann et al., 1998; Randerath et al., 2001), sleep efficiency (Konermann et al.”
BackgroundInfluentialHailey, D. M., Jacobs, P., Mayers, I., & Mensinkai, S. (2005) · Canadian Respiratory Journal · doi:10.1155/2005/870786 · Cited by 9
“CPAP – Sériès and Marc, 1997 (14) Morphée Plus** 21 APAP<CPAP NS – NS – NS – Meurice et al, 1996 (37) Morphée Plus 21 – NS NS – – APAP>CPAP – *Nellcor Puritan Bennett, France; †ResMed, Australia; ‡Weinmann, Germany; §Respironics, USA; ¶DeVilbiss, Germany; **Laboratoire Pierre Médical, France.”
InfluentialPositive Airway Pressure Treatment for Obstructive Sleep Apnea
Freedman, N. S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-24288-2.00115-x · Cited by 11
Tobin, M. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.5.2201061 · Cited by 9
Continuous Positive Airway Pressure Treatment and Adherence in Obstructive Sleep Apnea
Matthews, E. E., & Aloia, M. S. (2009) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2009.07.004 · Cited by 10
Randerath, W. J., & Herkenrath, S. D. (2017) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2017.02.002 · Cited by 7
Self-citationLangzeit-Compliance der CPAP-Therapie - aktueller Stand, Prädiktoren und Interventionsmöglichkeiten
Orth, M., Kotterba, S., Walther, J., Rasche, K., Schultze‐Werninghaus, G., & Duchna, H. W. (2006) · Pneumologie · doi:10.1055/s-2006-944234 · Cited by 17
Noninvasive ventilation in COPD
Herkenrath, S. D., Matthes, S., & Randerath, W. J. (2024) · European Respiratory Society eBooks · doi:10.1183/2312508x.10008123 · Cited by 6
Self-citationManagement of Obstructive Sleep Apnea–Hypopnea Syndrome
Phillips, B. A., & Kryger, M. H. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-6645-3.00110-9 · Cited by 8
Alamdari, H. H., Hacquebard, L. R. P., Driscoll, S., El‐Sankary, K., Roach, D. C., LeBlanc, R., Lowe, S., Oore, S., Penzel, T., Fietze, I., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3138965 · Cited by 5
Home Monitoring of Sleep Apnea Treatment: Benefits of Intelligent CPAP Devices
Boișteanu, D., Vasiluţă, R., Cernomaz, A. T., & Mucenica, C. (2009) · Advanced Technologies for Enhanced Quality of Life (AT-EQUAL) · doi:10.1109/at-equal.2009.25 · Cited by 8
“Studies comparing the effects of autotitrating CPAP devices with fixed pressure CPAP have consistently found that autotitrating CPAP is as effective at controlling sleep-disordered breathing as fixed pressure CPAP [5, 6, 9,10].”
BackgroundRanderath, W. J., & Fietze, I. (2009) · Respiration · doi:10.1159/000219303 · Cited by 5
Self-citationTreatment of obstructive sleep-disordered breathing with positive airway pressure systems
Pevernagie, D., Masa, J. F., Meurice, J. C., Farré, R., Marrone, O., & Rodenstein, D. O. (2007) · European Respiratory Review · doi:10.1183/09059180.00010603 · Cited by 5
Pépin, J., Gagnadoux, F., Foote, A., Vicars, R., Ogra, B., Viot-Blanc, V., Benmerad, M., d’Ortho, M., & Tamisier, R. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-015836 · Cited by 6
Kwon, O. E., Hah, Y., & Hong, I. H. (2021) · Journal of rhinology · doi:10.18787/jr.2020.00341 · Cited by 3
Rühle, K.-H., Domanski, U., & Nilius, G. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0657-7 · Cited by 3
“However it was also demonstrated that by this procedure at higher required pressures, the compliance of the patients was improved [3], and many patients report an improvement of subjective sleep quality [4].”
BackgroundSelf-citationAdherence to CPAP treatment and functional status in adult obstructive sleep apnea
Weaver, T. E., Reishtein, J. L., & Sawyer, A. M. (2011) · Informa Healthcare eBooks · doi:10.3109/9781420020885.022 · Cited by 5
Rühle, K.-H., Raschke, F., Fietze, I., Randerath, W. J., Wessendorf, T., Hein, H., & Schlafmedizin, D. A. A. D. D. G. F. S. U. (2004) · Somnologie - Schlafforschung und Schlafmedizin · doi:10.1111/j.1439-054x.2004.00024.x · Cited by 6
Self-citationAutomatic Positive Airway Pressure Titration and Treatment
Randerath, W. J. (2006) · KARGER eBooks · doi:10.1159/000093156 · Cited by 3
Self-citationAuto-CPAP or constant CPAP? The patient knows what's best!
Randerath, W. J. (2004) · Sleep Medicine · doi:10.1016/j.sleep.2004.01.017 · Cited by 3
Self-citationSleeper, G. P., Catullo, K. A., Chen, P., Patil, S. P., Strohl, K. P., & Chiang, A. A.-P. (2025) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.11624 · Cited by 3
Positive Airway Pressure Treatment
Berry, R. B. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-0326-9.00019-1 · Cited by 2
Metadata
- Authors
- RANDERATH, W. J., SCHRAEDER, O., GALETKE, W., FELDMEYER, F., & RÜHLE, K.-H.
- Affiliations
- Witten/Herdecke University (DE)
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-03-01
- Volume
- 163
- Issue
- 3
- Pages
- 652-657
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W1975723518
- Cited by
- 143
- References
- 28
- Citations by year
- 2025: 3 · 2024: 2 · 2023: 2 · 2022: 2 · 2021: 5 · 2020: 4 · 2019: 6 · 2018: 2 · 2017: 6 · 2016: 3 · 2014: 4 · 2013: 4 · 2012: 5
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Journal of Respiratory and Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- auto-titrating CPAP, paracetamol, obstructive sleep apnea, CPAP adherence, patient acceptance, sleep microstructure, arousal
- MeSH terms
- Female, Humans, Male, Middle Aged, Patient Compliance, Positive-Pressure Respiration, Prospective Studies, Electric Impedance, Cross-Over Studies, Sleep Apnea, Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.