Dilution of Respiratory Solutes in Exhaled Condensates
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Most exhaled water is produced as gaseous water vapor, which can be collected in cooled condensers. The presence of nonvolatile solutes in these condensates suggests that droplets of respiratory fluid (RF) have also been collected. However, calculation of RF solute concentrations from condensates requires estimation of the dilution of RF droplets by water vapor. We used condensate electrolyte concentrations to calculate the dilution of RF droplets in condensates from 20 normal subjects. The total ionic concentration (conductivity) was 497 plus minus 68 (mean plus minus SEM) muM. Of this, 229 plus minus 43 muM was NH(4)(+), but little NH(4)(+) was collected from subjects with tracheostomies, indicating oral formation. The Na+ concentration in condensate ([Na+](cond)) averaged 242 plus minus 43 muM. Large variations in [Na(+)](cond) correlated well with variations of K+ in condensate ([K+](cond)) and Cl-) in condensate ([Cl-](cond)), and were attributed to differences in respiratory droplet dilution. Dividing condensate values of ([Na+] + [K+] ) by those of plasma indicated that RF represented between 0.01% and 2.00% of condensate volumes. Calculated values for Na+, K+, Cl-, lactate, and protein in RF were [Na+](RF) = 91 +/- 8 mM, [K+](RF) = 60 +/- 11 mM, [Cl-](RF) = 102 +/- 17 mM, [lactate](RF) = 44 +/- 17 mM, and [protein](RF) = 7.63 +/- 1.82 g/dl, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Harrison's Principles of Internal Medicine.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-499_2 · Cited by 12,514
(2012) · Hepatogastroenterology · doi:10.5754/hge12469 · Cited by 3,178
Matsui, H., Grubb, B. R., Tarran, R., Randell, S. H., Gatzy, J. T., Davis, C. W., & Boucher, R. C. (1998) · Cell · doi:10.1016/s0092-8674(00)81724-9 · Cited by 1,169
Clinical Physiology of Acid-Base and Electrolyte Disorders
(1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-2-176_8 · Cited by 1,156
Cystic Fibrosis Airway Epithelia Fail to Kill Bacteria Because of Abnormal Airway Surface Fluid
Smith, J. J., Travis, S. M., Greenberg, E. P., & Welsh, M. J. (1996) · Cell · doi:10.1016/s0092-8674(00)81099-5 · Cited by 1,039
Exhaled Markers of Pulmonary Disease
KHARITONOV, S. A., & BARNES, P. J. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.7.2009041 · Cited by 844
Endogenous Airway Acidification: Implications for Asthma Pathophysiology
HUNT, J. F., FANG, K., MALIK, R., SNYDER, A., MALHOTRA, N., PLATTS-MILLS, T. A. E., & GASTON, B. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.161.3.9911005 · Cited by 649
Increased 8-Isoprostane, a Marker of Oxidative Stress, in Exhaled Condensate of Asthma Patients
MONTUSCHI, P., CORRADI, M., CIABATTONI, G., NIGHTINGALE, J., KHARITONOV, S. A., & BARNES, P. J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.1.9809140 · Cited by 551
MONTUSCHI, P., COLLINS, J. V., CIABATTONI, G., LAZZERI, N., CORRADI, M., KHARITONOV, S. A., & BARNES, P. J. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.3.2001063 · Cited by 548
Dekhuijzen, P. N., Aben, K. K., Dekker, I., Aarts, L. P., Wielders, P. L., van Herwaarden, C. L., & Bast, A. (1996) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.154.3.8810624 · Cited by 503
Cited by
Exhaled breath condensate: methodological recommendations and unresolved questions
Horváth, I., Hunt, J., & Barnes, P. J. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00029705 · Cited by 1,284
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
How far droplets can move in indoor environments ? revisiting the Wells evaporation?falling curve
Xie, X., Li, Y., Chwang, A. T. Y., Ho, P. L., & Seto, W. H. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00469.x · Cited by 966
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867
“The regression equation did not account for water loss from the larger particles prior to deposition onto bond paper,(13) and there was no adjustment for evaporative water loss from the smaller particles collected on the Millipore filter.”
BackgroundMarr, L. C., Tang, J. W., Van Mullekom, J., & Lakdawala, S. S. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0298 · Cited by 430
Exhaled breath condensate: An evolving tool for noninvasive evaluation of lung disease
Hunt, J. (2002) · Journal of Allergy and Clinical Immunology · doi:10.1067/mai.2002.124966 · Cited by 345
Evaporation and dispersion of respiratory droplets from coughing
Liu, L., Wei, J., Li, Y., & Ooi, A. (2017) · Indoor Air · doi:10.1111/ina.12297 · Cited by 325
Physico-chemical characteristics of evaporating respiratory fluid droplets
Vejerano, E. P., & Marr, L. C. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0939 · Cited by 314
Short-range airborne transmission of expiratory droplets between two people
Liu, L., Li, Y., Nielsen, P. V., Wei, J., & Jensen, R. L. (2017) · Indoor Air · doi:10.1111/ina.12314 · Cited by 310
Exhaled leukotrienes and prostaglandins in COPD
Montuschi, P. (2003) · Thorax · doi:10.1136/thorax.58.7.585 · Cited by 293
Exhaled breath condensate pH is a robust and reproducible assay of airway acidity
Vaughan, J., Ngamtrakulpanit, L., Pajewski, T. N., Turner, R., Nguyen, T.-A., Smith, A., Urban, P., Hom, S., Gaston, B., & Hunt, J. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00038803 · Cited by 289
Recent advances in wide bandgap semiconductor biological and gas sensors
Pearton, S. J., Ren, F., Wang, Y.-L., Chu, B. H., Chen, K. H., Chang, C. Y., Lim, W., Lin, J., & Norton, D. P. (2010) · Progress in Materials Science · doi:10.1016/j.pmatsci.2009.08.003 · Cited by 286
Yang, W., Elankumaran, S., & Marr, L. C. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046789 · Cited by 274
Exhaled biomarkers in lung cancer
Horváth, I., Lázár, Z., Gyulai, N., Kollai, M., & Losonczy, G. (2009) · European Respiratory Journal · doi:10.1183/09031936.00142508 · Cited by 268
Dynamics of Airborne Influenza A Viruses Indoors and Dependence on Humidity
Yang, W., & Marr, L. C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0021481 · Cited by 263
A Simple Method for Estimating Respiratory Solute Dilution in Exhaled Breath Condensates
Effros, R. M., Biller, J., Foss, B., Hoagland, K., Dunning, M. B., Castillo, D., Bosbous, M., Sun, F., & Shaker, R. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200307-920oc · Cited by 221
Self-citationExhaled Breath Condensate: An Overview
Hunt, J. (2007) · Immunology and Allergy Clinics of North America · doi:10.1016/j.iac.2007.09.001 · Cited by 201
“Estimates of the dilution of ALF particles in EBC range from 20-fold to 30,000- fold(10).”
BackgroundBaker, E. H., Clark, N., Brennan, A. L., Fisher, D. A., Gyi, K. M., Hodson, M. E., Philips, B. J., Baines, D. L., & Wood, D. M. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01425.2006 · Cited by 200
“Previous studies have shown that respiratory fluid is diluted up to 10,000 times in condensate by water vapor (9, 10).”
Aldehydes and Glutathione in Exhaled Breath Condensate of Children with Asthma Exacerbation
Corradi, M., Folesani, G., Andreoli, R., Manini, P., Bodini, A., Piacentini, G., Carraro, S., Zanconato, S., & Baraldi, E. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200206-507oc · Cited by 199
Kubáň, P., & Foret, F. (2013) · Analytica Chimica Acta · doi:10.1016/j.aca.2013.07.049 · Cited by 194
Comparison of Biomarkers in Exhaled Breath Condensate and Bronchoalveolar Lavage
Jackson, A. S., Sandrini, A., Campbell, C., Chow, S., Thomas, P. S., & Yates, D. H. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200601-107oc · Cited by 159
Relative humidity in droplet and airborne transmission of disease
Božič, A., & Kanduč, M. (2021) · Journal of Biological Physics · doi:10.1007/s10867-020-09562-5 · Cited by 142
Parienta, D., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2010.10.005 · Cited by 82
Exhaled markers of inflammatory lung diseases: ready for routine monitoring?
Kharitonov, S. (2004) · Swiss Medical Weekly · doi:10.4414/smw.2004.10411 · Cited by 74
Jouyban, A., Farajzadeh, M. A., Khoubnasabjafari, M., Jouyban-Gharamaleki, V., & Afshar Mogaddam, M. R. (2019) · Analytical Methods · doi:10.1039/c8ay02279h · Cited by 24
Metadata
- Authors
- EFFROS, R. M., HOAGLAND, K. W., BOSBOUS, M., CASTILLO, D., FOSS, B., DUNNING, M., GARE, M., LIN, W., & SUN, F.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2002-03-01
- Volume
- 165
- Issue
- 5
- Pages
- 663-669
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2102683270
- Cited by
- 386
- References
- 44
- FWCI
- 26.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.