Deposition, Retention, and Translocation of Ultrafine Particles from the Central Airways and Lung Periphery
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
RATIONALE: Little is known about clearance of ultrafine carbon particles from the different regions of the human lung. These particles may accumulate and present a health hazard because of their high surface area. OBJECTIVES: Technetium Tc 99m ((99m)Tc)-radiolabeled 100-nm-diameter carbon particles were inhaled by healthy nonsmokers, asymptomatic smokers, and by patients with chronic obstructive pulmonary disease (COPD). METHODS: Using a bolus inhalation technique, particle deposition was targeted either to the airways or to the lung periphery, and retention, clearance, and translocation were measured using retained radiotracer imaging. MEASUREMENTS AND MAIN RESULTS: In vitro studies revealed that mean leaching of soluble (99m)Tc-radiotracer from the carbon particles was 4.1 (2.6 [SD]) % after 24 hours. Cumulative (99m)Tc activity in urine at 24 hours was 1.1 (1.3) % of activity deposited in the lungs. In the lung periphery, particle retention was not affected by smoking or pulmonary disease; retention was 96 (3) % after 24 hours. The small amount of clearance could be attributed to leaching of the (99m)Tc label, suggesting negligible particle clearance. In healthy nonsmokers, retention of particles targeted to the airways was 89 (6) and 75 (10) % after 1.5 and 24 hours, respectively. Radiolabel activity did not accumulate in the liver. CONCLUSIONS: Within the limits of detection of our experimental system, most inhaled ultrafine carbon particles are retained in the lung periphery and in the conducting airways without substantial systemic translocation or accumulation in the liver at 48 hours. Repeated exposure may result in significant pulmonary accumulation of ultrafine particles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles
Oberdörster, G., Oberdörster, E., & Oberdörster, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7339 · Cited by 7,891
Lung volumes and forced ventilatory flows
Quanjer, P. H., Tammeling, G. J., Cotes, J. E., Pedersen, O. F., Peslin, R., & Yernault, J.-C. (1993) · European Respiratory Journal · doi:10.1183/09041950.005s1693 · Cited by 5,318
(1993) · PubMed · Cited by 3,827
Passage of inhaled particles into the blood circulation in humans
Nemmar, A., Hoet, P. H. M., Vanquickenborne, B., Dinsdale, D., Thomeer, M., Hoylaerts, M. F., Vanbilloen, H., Mortelmans, L., & Nemery, B. (2002) · Circulation · doi:10.1161/hc0402.104118 · Cited by 1,719 · cited 3×
“After inhalation, UPs may follow different pathways from those of fine particles, including translocation to the blood circulation and hence other organs (6, 7). Human studies give conflicting results: whereas Nemmar and colleagues ( 7 ) reported rapid uptake of radiolabeled carbon UPs into the bloodstream and deposit…”
ResultInfluentialGeiser, M., Rothen-Rutishauser, B., Kapp, N., Schürch, S., Kreyling, W., Schulz, H., Semmler, M., Hof, V. I., Heyder, J., & Gehr, P. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8006 · Cited by 1,407
Self-citationEpidemiology Standardization Project (American Thoracic Society).
Ferris, B. G. (1978) · PubMed · Cited by 1,372
Respiratory effects are associated with the number of ultrafine particles.
Peters, A., Wichmann, H. E., Tuch, T., Heinrich, J., & Heyder, J. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.4.9105082 · Cited by 1,260
Oberdörster, G., Sharp, Z., Atudorei, V., Elder, A., Gelein, R., Lunts, A., Kreyling, W., & Cox, C. (2002) · Journal of Toxicology and Environmental Health, Part A · doi:10.1080/00984100290071658 · Cited by 846
Self-citationSamet, J. M., Zeger, S. L., Dominici, F., Curriero, F. C., Coursac, I., Dockery, D. W., Schwartz, J. D., & Zanobetti, A. (2000) · PubMed · Cited by 843
Review of Epidemiological Evidence of Health Effects of Particulate Air Pollution
Pope, C. A., Dockery, D. W., & Schwartz, J. (1995) · Inhalation Toxicology · doi:10.3109/08958379509014267 · Cited by 833
LUNG FUNCTION STUDIES. II. THE RESPIRATORY DEAD SPACE
Fowler, W. S. (1948) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1948.154.3.405 · Cited by 567
Effect of the size and surface charge of polymer microspheres on their phagocytosis by macrophage
Tabata, Y., & Ikada, Y. (1988) · Biomaterials · doi:10.1016/0142-9612(88)90033-6 · Cited by 538
Ultrafine Particle Deposition and Clearance in the Healthy and Obstructed Lung
Brown, J. S., Zeman, K. L., & Bennett, W. D. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200205-399oc · Cited by 449
Comroe, J. H., & Fowler, W. S. (1951) · The American Journal of Medicine · doi:10.1016/0002-9343(51)90285-9 · Cited by 421
Ultrafine Particle–Lung Interactions: Does Size Matter?
Kreyling, W. G., Semmler-Behnke, M., & Möller, W. (2006) · Journal of Aerosol Medicine · doi:10.1089/jam.2006.19.74 · Cited by 394
Self-citationUltrafine particle deposition in subjects with asthma.
Chalupa, D. C., Morrow, P. E., Oberdörster, G., Utell, M. J., & Frampton, M. W. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.6851 · Cited by 354
Semmler, M., Seitz, J., Erbe, F., Mayer, P., Heyder, J., Oberdörster, G., & Kreyling, W. G. (2004) · Inhalation Toxicology · doi:10.1080/08958370490439650 · Cited by 340
Self-citationDo Inhaled Carbon Nanoparticles Translocate Directly into the Circulation in Humans?
Mills, N. L., Amin, N., Robinson, S. D., Anand, A., Davies, J., Patel, D., de la Fuente, J. M., Cassee, F. R., Boon, N. A., MacNee, W., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200506-865oc · Cited by 323
Surfactant displaces particles toward the epithelium in airways and alveoli
Schürch, S., Gehr, P., Im Hof, V., Geiser, M., & Green, F. (1990) · Respiration Physiology · doi:10.1016/0034-5687(90)90003-h · Cited by 281
Dosimetry and Toxicology of Ultrafine Particles
Kreyling, W. G., Semmler, M., & Möller, W. (2004) · Journal of Aerosol Medicine · doi:10.1089/0894268041457147 · Cited by 215
Self-citationHenderson, Y., Chillingworth, F. P., & Whitney, J. L. (1915) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1915.38.1.1 · Cited by 207
Kim, C. S., & Kang, T. C. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.3.9117024 · Cited by 189
Mucociliary and long-term particle clearance in the airways of healthy nonsmoker subjects
Möller, W., Häußinger, K., Winkler-Heil, R., Stahlhofen, W., Meyer, T., Hofmann, W., & Heyder, J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00970.2003 · Cited by 189
Self-citationDistribution Pattern of Inhaled Ultrafine Gold Particles in the Rat Lung
Takenaka, S., Karg, E., Kreyling, W. G., Lentner, B., Möller, W., Behnke-Semmler, M., Jennen, L., Walch, A., Michalke, B., Schramel, P., et al. (2006) · Inhalation Toxicology · doi:10.1080/08958370600748281 · Cited by 182
Self-citationSurfactant protein A (SP‐A): the alveolus and beyond
Khubchandani, K. R., & Snyder, J. M. (2001) · The FASEB Journal · doi:10.1096/fj.00-0318rev · Cited by 158
ANDERSON, P. J., Wilson, J. D., & Hiller, F. C. (1990) · CHEST Journal · doi:10.1378/chest.97.5.1115 · Cited by 144
Interpretation of "24 Hour Lung Retention" in Studies of Mucociliary Clearance
SMALDONE, G. C., PERRY, R. J., BENNETT, W. D., MESSINA, M. S., ZWANG, J., & ILOWITE, J. (1988) · Journal of Aerosol Medicine · doi:10.1089/jam.1988.1.11 · Cited by 105
Kreuter, J. (1983) · PubMed · Cited by 85
Brown, J. S., Zeman, K. L., & Bennett, W. D. (2001) · Journal of Aerosol Medicine · doi:10.1089/08942680152744659 · Cited by 71 · cited 1×
“Studies using fine particles (in the micron size range) showed increased particle deposition in smokers and in patients with COPD, which was attributed to increased impaction at bifurcations caused by airway obstructions, (22, 23 ).”
BackgroundFlow limitation, cough, and patterns of aerosol deposition in humans
Smaldone, G. C., & Messina, M. S. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.2.515 · Cited by 70
Influence of the spatial laser intensity distribution on laser nitriding of iron
Landry, F., Lieb, K. P., & Schaaf, P. (1999) · Journal of Applied Physics · doi:10.1063/1.370713 · Cited by 67
Ilowite, J. S., Smaldone, G. C., Perry, R. J., Bennett, W. D., & Foster, W. M. (1989) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1989.9935893 · Cited by 62
Distribution and Excretion of Technetium in Humans
Beasley, T. M., Palmer, H. E., & Nelp, W. B. (1966) · Health Physics · doi:10.1097/00004032-196610000-00004 · Cited by 61
Möller, W. B. (2001) · Experimental Lung Research · doi:10.1080/019021401753181827 · Cited by 58
Self-citationIncreased Fine Particle Deposition in Women with Asymptomatic Nonspecific Airway Hyperresponsiveness
Kohlhäufl, M. J., Brand, P., Scheuch, G., Meyer, T. S., Schulz, H., Häussinger, K., & Heyder, J. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9805036 · Cited by 56
Self-citationAerosol derived airway morphometry in healthy subjects
Brand, P., RIEGER, C. H. L., Beinert, T., & Heyder, J. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08101639 · Cited by 39
The morphology of mucus in mammalian pulmonary airways
As, A. V., & Webster, I. (1974) · Environmental Research · doi:10.1016/0013-9351(74)90071-1 · Cited by 39
Regional deposition and retention of particles in shallow, inhaled boluses: effect of lung volume
Bennett, W. D., Scheuch, G., Zeman, K. L., Brown, J. S., Kim, C., Heyder, J., & Stahlhofen, W. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.1.168 · Cited by 36
Self-citationDetection of early lung impairment with aerosol bolus dispersion
Brand, P., Tuch, T., Manuwald, O., Bischof, W., Heinrich, J., Wichmann, H. ‐., Beinert, T., & Heyder, J. (1994) · European Respiratory Journal · doi:10.1183/09031936.94.07101830 · Cited by 31
Long-Term Lung Clearance of195Au-Labeled Teflon Particles in Humans
Philipson, K., Falk, R., Gustafsson, J., & Camner, P. (1996) · Experimental Lung Research · doi:10.3109/01902149609074018 · Cited by 30
Geiser, M., Hof, V. I., Gehr, P., & Cruz-Orive, L. M. (1990) · Journal of Aerosol Medicine · doi:10.1089/jam.1990.3.131 · Cited by 28
Biodegradable PEGylated Microspheres and Nanospheres
Sinha, V. R., Aggarwal, A., & Trehan, A. (2004) · American Journal of Drug Delivery · doi:10.2165/00137696-200402030-00002 · Cited by 25
Surfactant–ultrafine particle interactions: what we can learn from PM 10 studies
Gehr, P., Geiser, M., Hof, V. I., & Schürch, S. (2000) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2000.0679 · Cited by 25
Totraumbestimmung nach Fowler bei Patienten mit Lungenemphysem mit Hilfe von C18O2
Meyer, T. S., Schulz, H., Brand, P., Kohlhäufl, M. J., Heyder, J., & Häußinger, K. (2001) · Pneumologie · doi:10.1055/s-2001-12283 · Cited by 8
Use of Technegas as a radiopharmaceutical for the measurement of gastric emptying
Kwiatek, M. A., Jones, K. L., Burch, W. M., Horowitz, M., & Bartholomeusz, F. D. L. (1999) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050466 · Cited by 7
Cited by
The health effects of ultrafine particles
Schraufnagel, D. E. (2020) · Experimental & Molecular Medicine · doi:10.1038/s12276-020-0403-3 · Cited by 1,044
Deposition and biokinetics of inhaled nanoparticles
Geiser, M., & Kreyling, W. G. (2010) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-7-2 · Cited by 747
“Further evidence for a correlation between geometric particle diameter and prolonged particle retention in airways was recently obtained from a study targeting 100 nm carbon particles to human airways by shallow aerosol bolus inhalation [42,51].”
BackgroundSelf-citationRapid translocation of nanoparticles from the lung airspaces to the body
Choi, H. S., Ashitate, Y., Lee, J. H., Kim, S. H., Matsui, A., Insin, N., Bawendi, M. G., Semmler-Behnke, M., Frangioni, J. V., & Tsuda, A. (2010) · Nature Biotechnology · doi:10.1038/nbt.1696 · Cited by 648
Inhaled Nanoparticles Accumulate at Sites of Vascular Disease
Miller, M. R., Raftis, J. B., Langrish, J. P., McLean, S. G., Samutrtai, P., Connell, S. P., Wilson, S., Vesey, A. T., Fokkens, P. H. B., Boere, A. J. F., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b08551 · Cited by 609
Role of oxidative damage in toxicity of particulates
Møller, P., Jacobsen, N. R., Folkmann, J. K., Danielsen, P. H., Mikkelsen, L., Hemmingsen, J. G., Vesterdal, L. K., Forchhammer, L., Wallin, H., & Loft, S. (2010) · Free Radical Research · doi:10.3109/10715760903300691 · Cited by 453
Metadata
- Authors
- Möller, W., Felten, K., Sommerer, K., Scheuch, G., Meyer, G., Meyer, P., Häussinger, K., & Kreyling, W. G.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-02-15
- Volume
- 177
- Issue
- 4
- Pages
- 426-432
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2120351270
- Cited by
- 364
- References
- 45
- FWCI
- 21.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.