The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Predicting subjective judgment of best focus with objective image quality metrics
Open accessAbstract
PURPOSE: To determine the impact of higher-order monochromatic aberrations on lower-order subjective sphero-cylindrical refractions. METHODS: Computationally-aberrated, monochromatic Sloan letters were presented on a high luminance display that was viewed by an observer through a 2.5mm pupil. Through-focus visual acuity (VA) was determined in the presence of spherical aberration (Z40) at three levels (0.10, 0.21 and 0.50D). Analogous through-astigmatism experiments measured visual acuity in the presence of secondary astigmatism (Z4+/-2) or coma (Z3-1). Measured visual acuity was correlated with 31 different metrics of image quality to determine which metric best predicts performance for degraded retinal images. The defocus and astigmatism levels that optimized each metric were compared with those that produced best visual acuity to determine which metric best predicts subjective refraction. RESULTS: Spherical aberration, coma and secondary astigmatism all reduced VA and increased depth of focus. The levels of defocus and primary astigmatism that produced the best performance varied with levels of spherical aberration and secondary astigmatism, respectively. The presence of coma, however, did not affect cylindrical refraction. Image plane metrics, especially those that take into account the neural contrast sensitivity threshold (e.g. the visual Strehl ratio, VSOTF), are good predictors of visual acuity in both the through-focus and through-astigmatism experiments (R = -0.822 for VSOTF). Subjective sphero-cylindrical refractions were accurately predicted by some image-quality metrics (e.g., pupil fraction, VSOTF and standard deviation of PSF light distribution). CONCLUSION: Subjective judgment of best focus does not minimize RMS wavefront error (Zernike defocus = 0), nor create paraxial focus (Seidel defocus = 0), but makes the retina conjugate to a plane between these two. It is possible to precisely predict subjective sphero-cylindrical refraction for monochromatic light using objective metrics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards for Reporting the Optical Aberrations of Eyes
Thibos, L. N., Applegate, R. A., Schwiegerling, J. T., Webb, R., & Members, V. S. T. (2000) · Vision Science and its Applications · doi:10.1364/vsia.2000.suc1 · Cited by 824
Self-citationMonochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
Thibos, L. N., Hong, X., Bradley, A., & Cheng, X. (2002) · Journal of the Optical Society of America A · doi:10.1364/josaa.19.002329 · Cited by 622
Self-citationAccuracy and precision of objective refraction from wavefront aberrations
Thibos, L. N., Hong, X., Bradley, A., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.9 · Cited by 570
Self-citationInteraction between aberrations to improve or reduce visual performance
Applegate, R. A., Marsack, J. D., Ramos, R., & Sarver, E. J. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00334-1 · Cited by 403
Visual Acuity as a Function of Zernike Mode and Level of Root Mean Square Error
Applegate, R. A., Ballentine, C. S., Gross, H., Sarver, E. J., & SARVER, C. A. (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01600.x · Cited by 245
Clinical results of wavefront-guided laser in situ keratomileusis 3 months after surgery
Mrochen, M., Kaemmerer, M., & Seiler, T. (2001) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(00)00827-0 · Cited by 238
A Method to Predict Refractive Errors from Wave Aberration Data
Guirao, A., & Williams, A. (2003) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2003.tb01588.x · Cited by 162
Subjective Depth-of-Focus of the Eye
Atchison, D. A., Charman, W. N., & Woods, R. L. (1997) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1997.tb04744.x · Cited by 158
Reliability of refraction--a literature review.
(1996) · Cited by 141
Validation of a Clinical Shack-Hartmann Aberrometer
Cheng, X., Himebaugh, N. L., Kollbaum, P. S., et al. (2003) · Optometry and Vision Science · doi:10.1097/00006324-200308000-00013 · Cited by 134
Self-citationEstimating Visual Quality from Wavefront Aberration Measurements
Cheng, X., Thibos, L. N., & Bradley, A. (2003) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20030901-14 · Cited by 102
Self-citationKoomen, M. J., Scolnik, R., & Tousey, R. (1951) · Journal of the Optical Society of America · doi:10.1364/josa.41.000080 · Cited by 99
The refraction of the eye in the relation to spherical aberration and pupil size.
Charman, W. N., Jennings, J. A. M., & Whitefoot, H. (1978) · PubMed · Cited by 77
Cited by
Accuracy and precision of objective refraction from wavefront aberrations
Thibos, L. N., Hong, X., Bradley, A., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.9 · Cited by 570
Self-citationLegras, R., Benard, Y., & Lopez-Gil, N. (2012) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.10.032 · Cited by 46
Correction of presbyopia: old problems with old (and new) solutions
Kollbaum, P. S., & Bradley, A. (2020) · Clinical and Experimental Optometry · doi:10.1111/cxo.12987 · Cited by 45
Self-citation
Metadata
- Authors
- Cheng, X., Bradley, A., & Thibos, L. N.
- Venue
- Journal of Vision
- Published
- 2004-04-23
- Volume
- 4
- Issue
- 4
- Pages
- 7
- ISSN
- 1534-7362 (ISSN-L)
- OpenAlex
- W1975058461
- Cited by
- 255
- References
- 14
- FWCI
- 7.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.