CoChat

Phosphenes Electrically Evoked with DTL Electrodes: A Study in Patients with Retinitis Pigmentosa, Glaucoma, and Homonymous Visual Field Loss and Normal Subjects

Gekeler, Florian, Messias, Andre, Ottinger, Max, Bartz-Schmidt, Karl Ulrich, Zrenner, Eberhart · 2006 · Investigative Opthalmology & Visual Science
Cited by 83

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: To develop an improved, easy, and safe method for reliably eliciting electrical phosphenes and to compare reported perceptions and values of chronaxie and rheobase in healthy individuals and patients with distinct ophthalmic diseases. METHODS: DTL electrodes were used with a four-alternative, forced-choice method to determine psychophysically the strength-duration curves by using the Weiss model of electrical tissue stimulation in 47 subjects: healthy individuals (n = 17; n = 6 under light- and dark-adapted conditions), patients with open-angle glaucoma (n = 9), retinitis pigmentosa (RP; n = 14), amblyopia (n = 3), or homonymous visual field loss (n = 4). RESULTS: In all subjects, thresholds were safely determined without side effects. Subjects reported a homogenous, central, white, steady phosphene. The rheobase was higher in glaucoma and patients with RP than in healthy subjects (0.1129 +/- 0.0314 and 0.6868 +/- 0.1054 vs. 0.0383 +/- 0.0057 mA; P = 0.05 and <0.00001, respectively), and it increased with age (r = 0.51; P = 0.038). The rheobase was lower in light- than in dark-adapted conditions (difference 0.015 mA; P = 0.016). In patients with RP, no correlation was found between rheobase or chronaxie and retinal thickness (in OCT) or number of years after reading loss, but there was a correlation between rheobase and visual acuity (P = 0.014). In patients with RP or glaucoma, no inhomogeneity of phosphenes was reported, but all patients with homonymous visual field loss reported lateralization of the phosphene into the area of visual loss. CONCLUSIONS: Use of DTL electrodes to elicit electrical phosphenes is safe, fast, and reliable. It bears significant advantages over corneal electrodes and provides a valuable tool to elucidate ophthalmologic disease processes and to screen candidates for retinal prostheses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.06-0459

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Gekeler, F., Messias, A., Ottinger, M., Bartz-Schmidt, K. U., & Zrenner, E.
Venue
Investigative Opthalmology & Visual Science
Published
2006-11-01
Volume
47
Issue
11
Pages
4966
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2043672825
Cited by
83
References
2
FWCI
1.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.