Phosphenes Electrically Evoked with DTL Electrodes: A Study in Patients with Retinitis Pigmentosa, Glaucoma, and Homonymous Visual Field Loss and Normal Subjects
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To develop an improved, easy, and safe method for reliably eliciting electrical phosphenes and to compare reported perceptions and values of chronaxie and rheobase in healthy individuals and patients with distinct ophthalmic diseases. METHODS: DTL electrodes were used with a four-alternative, forced-choice method to determine psychophysically the strength-duration curves by using the Weiss model of electrical tissue stimulation in 47 subjects: healthy individuals (n = 17; n = 6 under light- and dark-adapted conditions), patients with open-angle glaucoma (n = 9), retinitis pigmentosa (RP; n = 14), amblyopia (n = 3), or homonymous visual field loss (n = 4). RESULTS: In all subjects, thresholds were safely determined without side effects. Subjects reported a homogenous, central, white, steady phosphene. The rheobase was higher in glaucoma and patients with RP than in healthy subjects (0.1129 +/- 0.0314 and 0.6868 +/- 0.1054 vs. 0.0383 +/- 0.0057 mA; P = 0.05 and <0.00001, respectively), and it increased with age (r = 0.51; P = 0.038). The rheobase was lower in light- than in dark-adapted conditions (difference 0.015 mA; P = 0.016). In patients with RP, no correlation was found between rheobase or chronaxie and retinal thickness (in OCT) or number of years after reading loss, but there was a correlation between rheobase and visual acuity (P = 0.014). In patients with RP or glaucoma, no inhomogeneity of phosphenes was reported, but all patients with homonymous visual field loss reported lateralization of the phosphene into the area of visual loss. CONCLUSIONS: Use of DTL electrodes to elicit electrical phosphenes is safe, fast, and reliable. It bears significant advantages over corneal electrodes and provides a valuable tool to elucidate ophthalmologic disease processes and to screen candidates for retinal prostheses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matter
Nowak, L. G., & Bullier, J. (1998) · Experimental Brain Research · doi:10.1007/s002210050304 · Cited by 492
Cited by
Axonal Sodium-Channel Bands Shape the Response to Electric Stimulation in Retinal Ganglion Cells
Fried, S. I., Lasker, A. C. W., Desai, N. J., Eddington, D. K., & Rizzo, J. F. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91081.2008 · Cited by 206
Edwards, T. L., Cottriall, C. L., Xue, K., Simunovic, M. P., Ramsden, J. D., Zrenner, E., & MacLaren, R. E. (2018) · Ophthalmology · doi:10.1016/j.ophtha.2017.09.019 · Cited by 193
“The utility of both external or internal electrical retinal stimulation to predict the sensitivity of the human visual system has been reported in a number of disease states.(17,18) Because a degree of ganglion cell loss undoubtedly occurs in end-stage RP,(19) it was critical to screen potential participants for resid…”
BackgroundSelf-citationSchatz, A., Röck, T., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T., Bartz-Schmidt, K. U., Zrenner, E., Messias, A., & Gekeler, F. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6932 · Cited by 158
“In addition, we found that DTL electrodes were tolerated very well and seemed as apt for continuous stimulation in TES as they were for phosphene threshold assessment.(15) DTL electrodes bear important potential advantages over many other electrodes, among them their high tolerability and cheap production costs.”
BackgroundMethodSelf-citationWilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155
“Electrical excitability of the retina was affirmed by transcorneal electrical stimulation with DTL electrodes before inclusion.(42) All participants gave written consent according to the Declaration of Helsinki.”
MethodSelf-citationPsychophysical evaluation for visual prosthesis
Dagnelie, G. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160529 · Cited by 82
“In patients without appreciable light perception, one can use an electrically evoked potential through a contact lens, DTL (after the inventors Dawson, Trick, and Lutzkow), or skin electrode (53, 54).”
Background
Metadata
- Authors
- Gekeler, F., Messias, A., Ottinger, M., Bartz-Schmidt, K. U., & Zrenner, E.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2006-11-01
- Volume
- 47
- Issue
- 11
- Pages
- 4966
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2043672825
- Cited by
- 83
- References
- 2
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.