The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Corneal Hysteresis but Not Corneal Thickness Correlates with Optic Nerve Surface Compliance in Glaucoma Patients
Abstract
PURPOSE: To investigate relationships between acute intraocular pressure (IOP)-induced optic nerve head surface deformation and corneal hysteresis and thickness in glaucomatous and nonglaucomatous human eyes. METHODS: This was a prospective experimental study of 100 subjects (38 with glaucoma, 62 without glaucoma). Data collected included spherical equivalent, optic disc diameter, central corneal thickness (CCT), axial length, cylinder, Goldmann IOP, Pascal IOP, and ocular pulse amplitude and ocular response analyzer (ORA) measurements of corneal hysteresis (CH). Elevation of IOP was induced in the right eye of each subject with a modified LASIK suction ring to an average of 64 mm Hg for less than 30 seconds. Heidelberg Retina Tomography II (HRT) was used to map the optic nerve surface before and during IOP elevation. Mean cup depth was calculated using built-in HRT data analysis software. Change in optic disc depth during IOP elevation was calculated for all right eyes, and tests for correlation with the parameters listed were performed. RESULTS: Both CH and CCT were lower in the glaucoma group (8.8 mm Hg and 532 microm) than in the control group (9.6 mm Hg, P = 0.012; 551 microm, P = 0.011, respectively). There were no statistically significant differences in spherical equivalent, cylinder, axial length, optic disc size, or ocular pulse amplitude between the glaucoma and the control groups. There was no difference between the amount of IOP elevation between the two groups (P = 0.41), and the average difference in mean cup depth between baseline (mean cup depth, 247 microm) and during IOP elevation was 33 microm (29.8 microm in glaucoma and 36.1 microm in control; P = 0.5). Multiple variable analysis, controlling for age and sex, showed that CH was correlated with mean cup depth increase (P = 0.032). This relationship persisted (P = 0.032) after controlling for glaucoma status in addition to age and sex. Other factors, including CCT (P = 0.3), axial length (P = 0.9), ocular pulse amplitude (P = 0.22), and spherical equivalent (P = 0.38), were not significant in this model. CONCLUSIONS: In the glaucoma patients but not the control patients, CH but not CCT or other anterior segment parameters was associated with increased deformation of the optic nerve surface during transient elevations of IOP. (ClinicalTrials.gov number, NCT00328835.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gordon, M. O. (2002) · Archives of Ophthalmology · doi:10.1001/archopht.120.6.714 · Cited by 2,626
Predictors of Long-term Progression in the Early Manifest Glaucoma Trial
Leske, M. C., Heijl, A., Hyman, L., Bengtsson, B., Dong, L., & Yang, Z. (2007) · Ophthalmology · doi:10.1016/j.ophtha.2007.03.016 · Cited by 1,363
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311
Factors Influencing Optic Nerve Head Biomechanics
Sigal, I. A., Flanagan, J. G., & Ethier, C. R. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0541 · Cited by 507
Central Corneal Thickness and Corneal Hysteresis Associated With Glaucoma Damage
Congdon, N. G., Broman, A. T., Bandeen-Roche, K., Grover, D., & Quigley, H. A. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.12.007 · Cited by 507
Kotecha, A., Elsheikh, A., Roberts, C. R., Zhu, H., & Garway-Heath, D. F. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0557 · Cited by 423
Self-citationAssessment of Corneal Biomechanical Properties and Their Variation with Age
Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007) · Current Eye Research · doi:10.1080/02713680601077145 · Cited by 394
Deformation of the Lamina Cribrosa and Anterior Scleral Canal Wall in Early Experimental Glaucoma
Bellezza, A. J., Rintalan, C. J., Thompson, H. W., Downs, J. C., Hart, R. T., & Burgoyne, C. F. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.01-1282 · Cited by 372
(2007) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.075 · Cited by 359
Finite Element Modeling of Optic Nerve Head Biomechanics
Sigal, I. A., Flanagan, J. G., Tertinegg, I., et al. (2004) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0133 · Cited by 333
Nonlinear material properties of intact cornea and sclera
Woo, S. L., KOBAYASHI, A. S., Schlegel, W. A., & Lawrence, C. (1972) · Experimental Eye Research · doi:10.1016/0014-4835(72)90139-x · Cited by 323
Direct-Recorded Intraocular Pressure Variations in a Human Subject
Coleman, D. J., & Trokel, S. L. (1969) · Archives of Ophthalmology · doi:10.1001/archopht.1969.00990020633011 · Cited by 285
Medeiros, F. A., Sample, P. A., Zangwill, L. M., Bowd, C., Aihara, M., & Weinreb, R. N. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(03)00484-7 · Cited by 248
Age related compliance of the lamina cribrosa in human eyes
Albon, J. (2000) · British Journal of Ophthalmology · doi:10.1136/bjo.84.3.318 · Cited by 246
Reproducibility and Clinical Evaluation of Rebound Tonometry
Martinez-de-la-Casa, J. M., Garcia-Feijoo, J., Castillo, A., & Garcia-Sanchez, J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0586 · Cited by 201
Changes in the collagenous matrix of the aging human lamina cribrosa.
Albon, J., Karwatowski, W. S., Avery, N., Easty, D. L., & Duance, V. C. (1995) · British Journal of Ophthalmology · doi:10.1136/bjo.79.4.368 · Cited by 166
Iliev, M. E., Goldblum, D., Κatsoulis, Κ., Amstutz, C. A., & Frueh, B. E. (2006) · British Journal of Ophthalmology · doi:10.1136/bjo.2005.089870 · Cited by 138
The Intraocular Pressure and Drainage of the Aqueous Humour
Ridley, F. (1930) · PubMed Central · Cited by 57
Connective Tissue Structure of the Tree Shrew Optic Nerve and Associated Ageing Changes
Albon, J., Farrant, S., Akhtar, S., Young, R., Boulton, M. E., SMITH, G. M., Taylor, M., Guggenheim, J., & Morgan, J. E. (2007) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.06-0084 · Cited by 51
Hong, S., Kim, C. Y., Seong, G. J., & Hong, S. (2006) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.09.038 · Cited by 39
Cited by
Risk Factors for Visual Field Progression in Treated Glaucoma
De Moraes, C. G. V. (2010) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2011.72 · Cited by 356
Biomechanics of the optic nerve head
Sigal, I. A., & Ethier, C. R. (2009) · Experimental Eye Research · doi:10.1016/j.exer.2009.02.003 · Cited by 331
Corneal Hysteresis as a Risk Factor for Glaucoma Progression: A Prospective Longitudinal Study
Medeiros, F. A., Meira-Freitas, D., Lisboa, R., Kuang, T.-M., Zangwill, L. M., & Weinreb, R. N. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.01.032 · Cited by 283
Elasticity-Dependent Modulation of TGF-β Responses in Human Trabecular Meshwork Cells
Han, H., Wecker, T., Grehn, F., & Schlunck, G. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6640 · Cited by 79
Metadata
- Authors
- Wells, A. P., Garway-Heath, D. F., Poostchi, A., Wong, T., Chan, K. C. Y., & Sachdev, N.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2008-08-01
- Volume
- 49
- Issue
- 8
- Pages
- 3262
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2009719347
- Cited by
- 265
- References
- 20
- FWCI
- 17.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.