PURPOSE: To demonstrate the capability of SD-OCT to measure macular retinal ganglion cell-inner plexiform layer (GCIPL) thickness and to assess its reproducibility in glaucomatous eyes. METHODS: Fifty-one glaucomatous eyes (26 mild, 11 moderate, 14 severe) of 51 patients underwent macular scanning using the Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA) macula 200×200 acquisition protocol. Five scans were obtained on 5 days within 2 months. The ganglion cell analysis (GCA) algorithm was used to detect the macular GCIPL and to measure the thickness of the overall average, minimum, superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal GCIPL. The reproducibility of the measurements was evaluated with intraclass correlation coefficients (ICCs), coefficients of variation (COVs), and test-retest standard deviations (TRTSDs). RESULTS: Segmentation and measurement of GCIPL thickness were successful in 50 of 51 subjects. All ICCs ranged between 0.94 and 0.98, but ICCs for average and superior GCIPL parameters (0.97-0.98) were slightly higher than for inferior GCIPL parameters (0.94-0.97). All COVs were <5%, with 1.8% for average GCIPL and COVs for superior GCIPL parameters (2.2%-3.0%) slightly lower than those for inferior GCIPL parameters (2.5%-3.6%). The TRTSD was lowest for average GCIPL (1.16 μm) and varied from 1.43 to 2.15 μm for sectoral GCIPL CONCLUSIONS: The Cirrus HD-OCT GCA algorithm can successfully segment macular GCIPL and measure GCIPL thickness with excellent intervisit reproducibility. Longitudinal monitoring of GCIPL thickness may be possible with Cirrus HD-OCT for assessing glaucoma progression.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Topography of ganglion cells in human retina
Curcio, C. A., & Allen, K. A. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.903000103 · Cited by 1,844
The Wisconsin Age-related Maculopathy Grading System
Klein, R., Davis, M. D., Magli, Y. L., Segal, P., Klein, B. E. K., & Hubbard, L. (1991) · Ophthalmology · doi:10.1016/s0161-6420(91)32186-9 · Cited by 1,200
Chiu, S. J., Li, X. T., Nicholas, P., Toth, C. A., Izatt, J. A., & Farsiu, S. (2010) · Optics Express · doi:10.1364/oe.18.019413 · Cited by 733
Detection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography
Tan, O., Chopra, V., Lu, A. T.-H., Schuman, J. S., Ishikawa, H., Wollstein, G., Varma, R., & Huang, D. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.05.025 · Cited by 665
Garvin, M. K., Abramoff, M. D., Wu, X., Russell, S. R., Burns, T. L., & Sonka, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2016958 · Cited by 626
Macular Segmentation with Optical Coherence Tomography
Ishikawa, H., Stein, D. M., Wollstein, G., Beaton, S., Fujimoto, J. G., & Schuman, J. S. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0335 · Cited by 498
Mapping of Macular Substructures with Optical Coherence Tomography for Glaucoma Diagnosis
Tan, O., Li, G., Lu, A. T.-H., Varma, R., & Huang, D. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.08.011 · Cited by 361
Garvin, M. K., Abramoff, M. D., Kardon, R., Russell, S. R., Wu, X., & Sonka, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923966 · Cited by 336
Quantitative detection of glaucomatous damage at the posterior pole by retinal thickness mapping
Zeimer, R. C., Asrani, S., Zou, S., Quigley, H. A., & JAMPEL, H. D. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)92743-9 · Cited by 268
Kim, N. R., Lee, E. S., Seong, G. J., Kim, J. H., An, H. G., & Kim, C. Y. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-5053 · Cited by 264
Seong, M., Sung, K. R., Choi, E. H., Kang, S. Y., Cho, J. W., Um, T. W., Kim, Y. J., Park, S. B., Hong, H. E., & Kook, M. S. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-4258 · Cited by 252
Intra-retinal layer segmentation in optical coherence tomography images
Mishra, A., Wong, A., Bizheva, K., & Clausi, D. A. (2009) · Optics Express · doi:10.1364/oe.17.023719 · Cited by 214
Quellec, G., Lee, K., Dolejsi, M., Garvin, M. K., Abramoff, M. D., & Sonka, M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2047023 · Cited by 214
Wollstein, G., Schuman, J. S., Price, L. L., Aydin, A., Beaton, S. A., Stark, P. C., Fujimoto, J. G., & Ishikawa, H. (2004) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2004.03.019 · Cited by 198
Frishman, L. J., Shen, F., Du, L. Z., Robson, J. G., Harwerth, R. S., Smith, E. L., Carter‐Dawson, L. D., & Crawford, M. L. J. (1996) · PubMed · Cited by 180
Thickness Profiles of Retinal Layers by Optical Coherence Tomography Image Segmentation
Bagci, A. M., Shahidi, M., Ansari, R., Blair, M., Blair, N. P., & Zelkha, R. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.06.010 · Cited by 180
Kajic, V., Považay, B., Hermann, B. M., Höfer, B., Marshall, D., Rosin, P. L., & Drexler, W. (2010) · Optics Express · doi:10.1364/oe.18.014730 · Cited by 129
DeBuc, D. C., Somfai, G. M., Ranganathan, S., Tátrai, E., Ferencz, M., & Puliafito, C. A. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3268773 · Cited by 63
Automated segmentation of retinal layers in OCT imaging and derived ophthalmic measures
Rossant, F., Ghorbel, I., Isabelle Bloch, A., Pâques, M., & Tick, S. (2009) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2009.5193320 · Cited by 40
Cited by
Mwanza, J.-C., Durbin, M. K., Budenz, D. L., Sayyad, F. E., Chang, R. T., Neelakantan, A., Godfrey, D. G., Carter, R., & Crandall, A. S. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.014 · Cited by 421
Self-citationSpectral-Domain OCT Measurements in Alzheimer’s Disease
Chan, V. T. T., Sun, Z., Tang, S., Chen, L. J., Wong, A., Tham, C. C., Wong, T. Y., Chen, C., Ikram, M. K., Whitson, H. E., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.08.009 · Cited by 360
Karri, S. P. K., Chakraborty, D., & Chatterjee, J. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.000579 · Cited by 313
Saidha, S., Green, A. J., Leocani, L., Vidal-Jordana, A., Kenney, R. C., Bsteh, G., Outteryck, O., Thompson, A., Montalban, X., Coetzee, T., et al. (2025) · The Lancet Neurology · doi:10.1016/s1474-4422(25)00275-3 · Cited by 66
Metadata
- Authors
- Mwanza, J.-C., Oakley, J. D., Budenz, D. L., Chang, R. T., Knight, O. J., & Feuer, W. J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-10-21
- Volume
- 52
- Issue
- 11
- Pages
- 8323
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1976491437
- Cited by
- 429
- References
- 19
- FWCI
- 27.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.