Automatic Drusen Quantification and Risk Assessment of Age-Related Macular Degeneration on Color Fundus Images
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate a machine learning algorithm that allows for computer-aided diagnosis (CAD) of nonadvanced age-related macular degeneration (AMD) by providing an accurate detection and quantification of drusen location, area, and size. METHODS: Color fundus photographs of 407 eyes without AMD or with early to moderate AMD were randomly selected from a large European multicenter database. A machine learning system was developed to automatically detect and quantify drusen on each image. Based on detected drusen, the CAD software provided a risk assessment to develop advanced AMD. Evaluation of the CAD system was performed using annotations made by two blinded human graders. RESULTS: Free-response receiver operating characteristics (FROC) analysis showed that the proposed system approaches the performance of human observers in detecting drusen. The estimated drusen area showed excellent agreement with both observers, with mean intraclass correlation coefficients (ICC) larger than 0.85. Maximum druse diameter agreement was lower, with a maximum ICC of 0.69, but comparable to the interobserver agreement (ICC = 0.79). For automatic AMD risk assessment, the system achieved areas under the receiver operating characteristic (ROC) curve of 0.948 and 0.954, reaching similar performance as human observers. CONCLUSIONS: A machine learning system capable of separating high-risk from low-risk patients with nonadvanced AMD by providing accurate detection and quantification of drusen, was developed. The proposed method allows for quick and reliable diagnosis of AMD, opening the way for large dataset analysis within population studies and genotype-phenotype correlation analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bird, A. C., Bressler, N. M., Bressler, S. B., Chisholm, I. H., Coscas, G., Davis, M. D., de Jong, P. T. V. M., Klaver, C. C. W., Klein, B. E. K., Klein, R., et al. (1995) · Survey of Ophthalmology · doi:10.1016/s0039-6257(05)80092-x · Cited by 1,926
Hageman, G. (2001) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(01)00010-6 · Cited by 1,265 · cited 8×
“Additionally, accurate quantitative measurements can help in large clinical studies for the evaluation and progression of drusen area, for example, in clinical trials concerning new therapeutic strategies for dry AMD, and it could help in applying inclusion criteria for large-scale clinical studies and genotype-phenot…”
BackgroundInfluentialRisk factors for age-related macular degeneration
Smith, W., Assink, J., Klein, R., Mitchell, P., Klaver, C. C. W., Klein, B. E. K., Hofman, A., Jensen, S., Wang, J. J., & de Jong, P. T. V. M. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00580-7 · Cited by 1,071
On the theory of dynamic programming
Bellman, R. (1952) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.38.8.716 · Cited by 998
Evans, J. R., & Lawrenson, J. G. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000254.pub4 · Cited by 335
Bressler, S. B. (1990) · Archives of Ophthalmology · doi:10.1001/archopht.1990.01070120090035 · Cited by 325
Seddon, J. M., Reynolds, R., Yu, Y., Daly, M. J., & Rosner, B. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.04.029 · Cited by 198 · cited 9×
“However, the presence of drusen alone is not directly correlated with the risk of progression to advanced AMD.(2) Other works focused on the automatic quantification of drusen without identifying patients at high risk or the AMD stage.”
BackgroundInfluentialKarnon, J., Czoski-Murray, C., Smith, K. J., & Brand, C. (2009) · Medical Decision Making · doi:10.1177/0272989x08327491 · Cited by 21 · cited 1×
“We are not aware of any implementation of AMD screening programs, but there have been studies evaluating cost effectiveness of such programs.(52,53) However, the proposed programs are based on self-testing, whereas screening based on evaluation of color fundus images would be preferable.”
Background
Cited by
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
van Grinsven, M. J. J. P., van Ginneken, B., Hoyng, C. B., Theelen, T., & Sanchez, C. I. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2526689 · Cited by 426
“The local maxima locations are used as seed points for dynamic programming to segment the individual hemorrhage candidates [36].”
MethodSelf-citationGonzález-Gonzalo, C., Thee, E. F., Klaver, C. C. W., Lee, A. Y., Schlingemann, R. O., Tufail, A., Verbraak, F., & Sánchez, C. I. (2022) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.101034 · Cited by 103
“…few observer studies have been performed in ophthalmology, they have shown that the performance AI systems can exceed that of observers in different tasks (Liefers et al., 2020, 2021; Chen et al., 2021; Gonz ´ alez-Gonzalo et al., 2020b; Venhuizen et al., 2017; van Grinsven et al., 2013, 2015).”
Self-citation
Metadata
- Authors
- van Grinsven, M. J. J. P., Lechanteur, Y. T. E., van de Ven, J. P. H., van Ginneken, B., Hoyng, C. B., Theelen, T., & Sánchez, C. I.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2013-04-30
- Volume
- 54
- Issue
- 4
- Pages
- 3019
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2007915816
- Cited by
- 51
- References
- 9
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Drusen Quantification and Risk Assessment of Age-Related Macular Degeneration on Color Fundus Images. https://app.cochat.ai/papers/10.1167/iovs.12-11449
- The paper
- van Grinsven, M. J. J. P., Lechanteur, Y. T. E., van de Ven, J. P. H., van Ginneken, B., Hoyng, C. B., Theelen, T., & Sánchez, C. I. (2013). Automatic Drusen Quantification and Risk Assessment of Age-Related Macular Degeneration on Color Fundus Images. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.12-11449
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.