The Post-Illumination Pupil Response (PIPR)
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
PURPOSE: The post-illumination pupil response (PIPR) has been quantified using four metrics, but the spectral sensitivity of only one is known; here we determine the other three. To optimize the human PIPR measurement, we determine the protocol producing the largest PIPR, the duration of the PIPR, and the metric(s) with the lowest coefficient of variation. METHODS: The consensual pupil light reflex (PLR) was measured with a Maxwellian view pupillometer. Experiment 1: Spectral sensitivity of four PIPR metrics (plateau, 6 seconds, area under curve early and late recovery) was determined from a criterion PIPR to a 1-second pulse and fitted with vitamin A1 nomogram (λ(max) = 482 nm). Experiment 2: The PLR was measured as a function of three stimulus durations (1 second, 10 seconds, 30 seconds), five irradiances spanning low to high melanopsin excitation levels (retinal irradiance: 9.8-14.8 log quanta.cm(-2).s(-1)), and two wavelengths, one with high (465 nm) and one with low (637 nm) melanopsin excitation. Intra- and interindividual coefficients of variation (CV) were calculated. RESULTS: The melanopsin (opn4) photopigment nomogram adequately describes the spectral sensitivity of all four PIPR metrics. The PIPR amplitude was largest with 1-second short-wavelength pulses (≥ 12.8 log quanta.cm(-2).s(-1)). The plateau and 6-second PIPR showed the least intra- and interindividual CV (≤ 0.2). The maximum duration of the sustained PIPR was 83.0 ± 48.0 seconds (mean ± SD) for 1-second pulses and 180.1 ± 106.2 seconds for 30-second pulses (465 nm; 14.8 log quanta.cm(-2).s(-1)). CONCLUSIONS: All current PIPR metrics provide a direct measure of the intrinsic melanopsin photoresponse. To measure progressive changes in melanopsin function in disease, we recommend that the PIPR be measured using short-duration pulses (e.g., ≤ 1 second) with high melanopsin excitation and analyzed with plateau and/or 6-second metrics. Our PIPR duration data provide a baseline for the selection of interstimulus intervals between consecutive pupil testing sequences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phototransduction by retinal ganglion cells that set the circadian clock
Berson, D. M., Dunn, F. A., & Takao, M. (2002) · Science · doi:10.1126/science.1067262 · Cited by 3,629
Dacey, D. M., Liao, H.-W., Peterson, B. B., Robinson, F. R., Smith, V. C., Pokorny, J., Yau, K.-W., & Gamlin, P. D. (2005) · Nature · doi:10.1038/nature03387 · Cited by 1,333
Measuring and using light in the melanopsin age
Lucas, R. J., Peirson, S. N., Berson, D. M., Brown, T. M., Cooper, H. M., Czeisler, C. A., Figueiro, M. G., Gamlin, P. D., Lockley, S. W., O’Hagan, J. B., et al. (2014) · Trends in Neurosciences · doi:10.1016/j.tins.2013.10.004 · Cited by 1,278
Hattar, S., Lucas, R. J., Mrosovsky, N., Thompson, S., Douglas, R. H., Hankins, M. W., Lem, J., Biel, M., Hofmann, F., Foster, R. G., et al. (2003) · Nature · doi:10.1038/nature01761 · Cited by 1,245
Human and macaque pupil responses driven by melanopsin-containing retinal ganglion cells
Gamlin, P. D. R., McDougal, D. H., Pokorny, J., Smith, V. C., Yau, K.-W., & Dacey, D. M. (2007) · Vision Research · doi:10.1016/j.visres.2006.12.015 · Cited by 617
Cited by
Melanopsin contributions to non-visual and visual function
Spitschan, M. (2019) · Current Opinion in Behavioral Sciences · doi:10.1016/j.cobeha.2019.06.004 · Cited by 146
“The diameter of the pupil is strongly controlled by melanopsin, in terms of steady-state pupil size [15–17], the return of pupil size to baseline after light offset [16,18,19], and dynamic pupil responses to, e.”
BackgroundPublication guidelines and recommendations for pupillary measurement in psychophysiological studies
Steinhauer, S. R., Bradley, M. M., Siegle, G. J., Roecklein, K. A., & Dix, A. (2022) · Psychophysiology · doi:10.1111/psyp.14035 · Cited by 137
Cone and melanopsin contributions to human brightness estimation
Zele, A. J., Adhikari, P., Feigl, B., & Cao, D. (2018) · Journal of the Optical Society of America A · doi:10.1364/josaa.35.000b19 · Cited by 97
Self-citationAttenuation of short wavelengths alters sleep and the ip RGC pupil response
Ostrin, L. A., Abbott, K. S., & Queener, H. M. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12385 · Cited by 69
Maruani, J., Vissouze, L., Hebert, M., Rach, H., Zehani, F., Lejoyeux, M., Bourgin, P., & Geoffroy, P. A. (2025) · Psychiatry Research · doi:10.1016/j.psychres.2024.116333 · Cited by 7
Metadata
- Authors
- Adhikari, P., Zele, A. J., & Feigl, B.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2015-06-11
- Volume
- 56
- Issue
- 6
- Pages
- 3838
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W571073904
- Cited by
- 173
- References
- 5
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.