Cited by 36Optical Coherence Tomography ApplicationsRetinal Diseases and TreatmentsRetinal Imaging and Analysis

Volumetric measurement of subretinal blebs using microscope-integrated optical coherence tomography

Open access
Hsu, S. Tammy, Gabr, Hesham, Viehland, Christian, Sleiman, Karim, Ngo, Hoan T., Carrasco-Zevallos, Oscar M., Vajzovic, Lejla, McNabb, Ryan P. +4 more·2018·Translational Vision Science & Technology

Abstract

Purpose: We advance studies of subretinal treatments by developing a microscope-integrated optical coherence tomography (MIOCT) image-based method for measuring the volume of therapeutics delivered into the subretinal space. Methods: A MIOCT image-based volume measurement method was developed and assessed for accuracy and reproducibility by imaging an object of known size in model eyes. This method then was applied to subretinal blebs created by injection of diluted triamcinolone. Bleb volumes obtained from MIOCT were compared to the intended injection volume and the surgeon's estimation of leakage. Results: Validation of the image-based volume measurement method showed accuracy to ±1.0 μL (6.0% of measured volume) with no statistically significant variation under different imaging settings. When this method was applied to subretinal blebs, four of 11 blebs without surgeon-observed leakage yielded a mean volume of 32 ± 12.5 μL, in contrast to the intended 50 μL volume injected from the delivery device. This constituted a mean difference of −18 μL (mean percent error, 36 ± 25%). For all 11 blebs, the surgeon's estimations of leakage were significantly different from and showed no correlation with the volume loss based on image-based volume measurements (P < 0.001, paired t-test; intraclass correlation = 0). Conclusions: We validated an accurate and reproducible method for measuring subretinal volumes using MIOCT. Use of this method revealed that the intended volume might not be delivered into the subretinal space. MIOCT can allow for accurate assessment of subretinal dose delivered, which may have therapeutic implications in evaluating the efficacy and toxicity of subretinal therapies. Translational Relevance: Use of MIOCT can provide feedback on the accuracy of subretinal injection volumes delivered.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/tvst.7.2.19

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Direct volumetric measurements using intraoperative OCT showed that subretinal bleb size was on average 36% smaller than predicted by the surgeon using a dilute triamcinolone solution.

    “Direct volumetric measurements using intraoperative OCT showed that subretinal bleb size was on average 36% smaller than predicted by the surgeon using a dilute triamcinolone solution (23).”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hsu, S. T., Gabr, H., Viehland, C., Sleiman, K., Ngo, H. T., Carrasco-Zevallos, O. M., Vajzovic, L., McNabb, R. P., Stinnett, S. S., Izatt, J. A., Kuo, A. N., & Toth, C. A.
Affiliations
  • Duke University (US)
  • Ain Shams University (EG)
  • Department of Biomedical Engineering, Duke University, Durham, NC, USA
Corresponding author
Toth, Cynthia A.
Venue
Translational Vision Science & Technology
Published
2018-04-05
Volume
7
Issue
2
Pages
19
ISSN
2164-2591 (ISSN-L)
OpenAlex
W2795968500
Cited by
36
References
32
Citations by year
2026: 2 · 2025: 5 · 2024: 8 · 2023: 2 · 2022: 4 · 2021: 4 · 2020: 8 · 2019: 2 · 2018: 1
FWCI
1.50
Type
journal article
Language
en
Open access
Locations
  • Translational Vision Science & Technology (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
National Eye Institute (R01EY023039)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
Keywords
subretinal injection, triamcinolone, bleb leak

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review