Usability and Safety in Electronic Medical Records Interface Design: A Review of Recent Literature and Guideline Formulation
The DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Objective: The objectives of this study were to (a) review electronic medical record (EMR) and related electronic health record (EHR) interface usability issues, (b) review how EMRs have been evaluated with safety analysis techniques along with any hazard recognition, and (c) formulate design guidelines and a concept for enhanced EMR interfaces with a focus on diagnosis and documentation processes. Background: A major impact of information technology in health care has been the introduction of EMRs. Although numerous studies indicate use of EMRs to increase health care quality, there remain concerns with usability issues and safety. Method: A literature search was conducted using Compendex, PubMed, CINAHL, and Web of Science databases to find EMR research published since 2000. Inclusion criteria included relevant English-language papers with subsets of keywords and any studies (manually) identified with a focus on EMR usability. Results: Fifty studies met the inclusion criteria. Results revealed EMR and EHR usability problems to include violations of natural dialog, control consistency, effective use of language, effective information presentation, and customization principles as well as a lack of error prevention, minimization of cognitive load, and feedback. Studies focusing on EMR system safety made no objective assessments and applied only inductive reasoning methods for hazard recognition. Conclusion: On the basis of the identified usability problems and structure of safety analysis techniques, we provide EMR design guidelines and a design concept focused on the diagnosis process and documentation. Application: The design guidelines and new interface concept can be used for prototyping and testing enhanced EMRs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
The magical number seven, plus or minus two: Some limits on our capacity for processing information.
Miller, G. A. (1956) · Psychological Review · doi:10.1037/h0043158 · Cited by 17,812
The magical number seven, plus or minus two: Some limits on our capacity for processing information.
Miller, G. A. (1994) · Psychological Review · doi:10.1037/0033-295x.101.2.343 · Cited by 17,161
Chaudhry, B., Wang, J., Wu, S., Maglione, M., Mojica, W., Roth, E., Morton, S. C., & Shekelle, P. G. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-10-200605160-00125 · Cited by 3,159 · cited 1×
“Moreover, Kalogriopoulos, Baran, Nimunkar, and Webster (2009); Chin and Sakuda (2012); Chaudhry et al. (2006); and Bates and Gawande (2003) all identified implementation of EMRs to have resulted in increased quality of health care systems, decreased errors by health care workers (HCWs), and savings…”
BackgroundA new accident model for engineering safer systems
Leveson, N. (2004) · Safety Science · doi:10.1016/s0925-7535(03)00047-x · Cited by 2,243 · cited 3×
“In STAMP, systems are considered as interrelated components that are maintained in a state of dynamic equilibrium by feedback loops of information and control (Leveson, 2004).”
BackgroundResultImproving Safety with Information Technology
Bates, D. W., & Gawande, A. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020847 · Cited by 1,544 · cited 1×
“Moreover, Kalogriopoulos, Baran, Nimunkar, and Webster (2009); Chin and Sakuda (2012); Chaudhry et al. (2006); and Bates and Gawande (2003) all identified implementation of EMRs to have resulted in increased quality of health care systems, decreased errors by health care workers (HCWs), and savings…”
BackgroundUse of Electronic Health Records in U.S. Hospitals
Jha, A. K., DesRoches, C. M., Campbell, E. G., Donelan, K., Rao, S. R., Ferris, T. G., Shields, A., Rosenbaum, S., & Blumenthal, D. (2009) · New England Journal of Medicine · doi:10.1056/nejmsa0900592 · Cited by 1,473 · cited 1×
“Related to these usability and safety issues, Jha et al. (2009) found that the use of EMRs in hospitals and clinics is not as great as the adoption of information technology for similar purposes (i.e., process documentation and decision making) as in other industries.”
BackgroundImproving a human-computer dialogue
Molich, R., & Nielsen, J. (1990) · Communications of the ACM · doi:10.1145/77481.77486 · Cited by 815 · cited 4×
“Molich and Nielsen (1990) recommended using short-cuts in order to make the system easy to use for all users.”
BackgroundMethodInfluentialThe Proximity Compatibility Principle: Its Psychological Foundation and Relevance to Display Design
Wickens, C. D., & Carswell, C. M. (1995) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872095779049408 · Cited by 655 · cited 1×
“To address this issue, they recommended presenting related items near each other (based on the proximity-compatibility principle described by Wickens and Carswell, 1995, according to which displays with relevance to a common task or mental operation should be rendered close together in perceptual…”
MethodInformatics in Primary Care: Strategies in Information Management for the Healthcare Provider
(2002) · Health Informatics · doi:10.1007/978-1-4613-0069-4 · Cited by 422
(2013) · Europe PMC (PubMed Central) · Cited by 396
Review of health information technology usability study methodologies
Yen, P.-Y., & Bakken, S. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2010-000020 · Cited by 390 · cited 2×
“Furthermore, the Yen and Bakken (2012) review focused on identification of usability study methodologies with application to health information technology and not usability issues in existing designs of EMRs.”
BackgroundTURF: Toward a unified framework of EHR usability
Zhang, J., & Walji, M. F. (2011) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2011.08.005 · Cited by 301 · cited 2×
“Although a lack of customization was one of the 14 usability principles that Zhang and Walji (2011) identified as an EMR issue, there are few studies that have focused on this issue.”
BackgroundSystem Safety Engineering And Risk Assessment: A Practical Approach
Bahr, N. J. (1997) · Cited by 212
Electronic health records and national patient-safety goals
Sittig, D. F., & Singh, H. (2012) · New England Journal of Medicine · doi:10.1056/nejmsb1205420 · Cited by 204 · cited 2×
“Alert-ing overload was also a usability and safety issue identified by Bouamrane and Mair (2013), Abramson et al. (2012), and Sittig and Singh (2012).”
BackgroundAhmed, A., Chandra, S., Herasevich, V., Gajic, O., & Pickering, B. W. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31821858a0 · Cited by 196 · cited 1×
“In another study, Ahmed, Chandra, Herasevich, Gajic, and Pickering (2011) identified user errors in EMR use due to information load and prototyped a new interface design that ranked data in terms of importance to a case and presented only highly ranked items on the screen for clinicians.”
BackgroundPrimary Care Physicians’ Use of an Electronic Medical Record System: A Cognitive Task Analysis
Shachak, A., Hadas-Dayagi, M., Ziv, A., & Reis, S. (2009) · Journal of General Internal Medicine · doi:10.1007/s11606-008-0892-6 · Cited by 188
Electronic Medical Records vs. Electronic Health Records:Yes,There Is a Difference
Yang, H. (2007) · Chinese Hospitals · Cited by 174
Using qualitative studies to improve the usability of an EMR
Rose, A. F., Schnipper, J. L., Park, E. R., Poon, E. G., Li, Q., & Middleton, B. (2005) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2004.11.006 · Cited by 169 · cited 4×
“Rose et al. (2005) sought to identify usability deficiencies in EMR design, including feature navigation.”
BackgroundMethodInfluentialMethods of information in medicine
(2014) · Methods of Information in Medicine · doi:10.3414/me · Cited by 157
Copy, Paste, and Cloned Notes in Electronic Health Records
Weis, J. M., & Levy, P. C. (2014) · CHEST Journal · doi:10.1378/chest.13-0886 · Cited by 154 · cited 1×
“In a more recent study, Weis and Levy (2014) identified benefits and risks of content-importing technologies (CIT), such as C/P functions in EHRs.”
BackgroundEvaluating usability of a commercial electronic health record: A case study
Edwards, P. J., Moloney, K. P., Jacko, J. A., & Sainfort, F. (2008) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2008.06.002 · Cited by 143 · cited 5×
“Edwards et al. (2008) also mentioned that the greatest trade-off in EHR design is providing a balance between efficient task performance and patient safety.”
BackgroundInfluentialPhysicians’ Attitudes Towards Copy and Pasting in Electronic Note Writing
O’Donnell, H. C., Kaushal, R., Barrón, Y., Callahan, M. A., Adelman, R. D., & Siegler, E. L. (2008) · Journal of General Internal Medicine · doi:10.1007/s11606-008-0843-2 · Cited by 135 · cited 1×
“Related to this finding, O’Donnell et al. (2009) also noted inconsistencies and outdated information as a result of C/P function use in patient notes.”
BackgroundFujitsu scientific and technical journal
富士通 (1965) · Medical Entomology and Zoology · Cited by 134
Direct text entry in electronic progress notes. An evaluation of input errors.
Weir, C. R., Hurdle, J. F., Felgar, M. A., Hoffman, J. M., Roth, B., & Nebeker, J. R. (2003) · PubMed · Cited by 122
Abramson, E. L., Patel, V., Malhotra, S., Pfoh, E. R., Osorio, S. N., Cheriff, A. D., Cole, C. L., Bunce, A., Ash, J. S., & Kaushal, R. (2012) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2012.02.010 · Cited by 114 · cited 3×
“Alert-ing overload was also a usability and safety issue identified by Bouamrane and Mair (2013), Abramson et al. (2012), and Sittig and Singh (2012).”
BackgroundDirect Text Entry in Electronic Progress Notes
Hurdle, J. F., Felgar, M. A., Hoffman, J. M., Roth, B., Nebeker, J. R., & Weir, C. R. (2003) · Methods of Information in Medicine · doi:10.1055/s-0038-1634210 · Cited by 109
Belden, J. L., Grayson, R. L., & Barnes, J. (2009) · MOspace Institutional Repository (University of Missouri) · Cited by 104
Assessing performance of an Electronic Health Record (EHR) using Cognitive Task Analysis
Saitwal, H., Feng, X., Walji, M. F., Patel, V. L., & Zhang, J. (2010) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2010.04.001 · Cited by 102
Technical evaluation, testing, and validatiaon of the usability of electronic health records
Lowry, S. Z., Quinn, M. T., Ramaiah, M., Schumacher, R. M., Patterson, E. S., North, R. A., Zhang, J., Gibbons, M. C., & Abbott, P. A. (2012) · doi:10.6028/nist.ir.7804 · Cited by 102 · cited 1×
“Some other technical reports have been published regarding the usability and safety of EHRs, such as Lowry et al. (2012).”
BackgroundCopying and pasting of examinations within the electronic medical record
Thielke, S. M., Hammond, K. W., & Helbig, S. (2006) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2006.06.004 · Cited by 101 · cited 1×
“Regarding C/P function use, Thielke, Hammond, and Helbig (2007) explored the prevalence of use in EMRs and the effect on medical errors by using an automated text categorization algorithm.”
MethodWalji, M. F., Kalenderian, E., Tran, D. T., Kookal, K. K., Nguyen, V., Tokede, O. A., White, J. M., Vaderhobli, R. M., Ramoni, R. B., Stark, P. C., et al. (2012) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2012.05.018 · Cited by 99 · cited 4×
“Walji et al. (2013) evaluated the usability of an EHR interface in order to identify some high-priority problems that could deteriorate user ability to perform tasks.”
BackgroundMethodInfluentialHarrington, L., Kennerly, D., & Johnson, C. (2011) · Journal of Healthcare Management · doi:10.1097/00115514-201101000-00006 · Cited by 93
Electronic medical record systems for developing countries: Review
Kalogriopoulos, N. A., Baran, J., Nimunkar, A. J., & Webster, J. G. (2009) · 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2009.5333561 · Cited by 88 · cited 1×
“Moreover, Kalogriopoulos, Baran, Nimunkar, and Webster (2009); Chin and Sakuda (2012); Chaudhry et al. (2006); and Bates and Gawande (2003) all identified implementation of EMRs to have resulted in increased quality of health care systems, decreased errors by health care workers (HCWs), and savings…”
BackgroundBad Health Informatics Can Kill – Is Evaluation the Answer?
Shaw, N. T., & Ammenwerth, E. (2005) · Methods of Information in Medicine · doi:10.1055/s-0038-1633915 · Cited by 82
Failure Mode and Effect Analysis
Ben‐Daya, M. (2009) · Springer eBooks · doi:10.1007/978-1-84882-472-0_4 · Cited by 78
Kumar, S., & Aldrich, K. (2010) · Health Informatics Journal · doi:10.1177/1460458210380523 · Cited by 74 · cited 2×
“In a similar study, Kumar and Aldrich (2010) analyzed a case of failure in health care due to EMR system failure.”
BackgroundMethodMcGuire, M., Noronha, G., Samal, L., Yeh, H., Crocetti, S., & Kravet, S. J. (2012) · Journal of General Internal Medicine · doi:10.1007/s11606-012-2153-y · Cited by 72 · cited 1×
“In addition, McGuire et al. (2013) found that EMRs, if designed and implemented properly, may promote safety culture in primary care providers.”
BackgroundHawai’i Journal of Medicine and Public Health
Beasley, H. (2014) · Wilderness and Environmental Medicine · doi:10.1016/j.wem.2014.06.006 · Cited by 70
Diaper, D. (2003) · Elsevier eBooks · doi:10.1016/b0-12-227410-5/00849-8 · Cited by 63
Use of a human factors approach to uncover informatics needs of nurses in documentation of care
Rogers, M. L., SOCKOLOW, P. S., Bowles, K. H., Hand, K. E., & George, J. (2013) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2013.08.007 · Cited by 61 · cited 5×
“Related to this problem, Rogers et al. (2013) mentioned that some functions of the NIS were unclear to nurses and they could not predict what would happen if they clicked them.”
BackgroundInfluentialHyman, D., Laire, M., Redmond, D., & Kaplan, D. W. (2012) · PEDIATRICS · doi:10.1542/peds.2011-2984 · Cited by 61
A study of general practitioners’ perspectives on electronic medical records systems in NHSScotland
Bouamrane, M.-M., & Mair, F. S. (2013) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-13-58 · Cited by 54 · cited 2×
“Alert-ing overload was also a usability and safety issue identified by Bouamrane and Mair (2013), Abramson et al. (2012), and Sittig and Singh (2012).”
BackgroundPre-post evaluation of physicians' satisfaction with a redesigned electronic medical record system.
Jaspers, M., Peute, L., Lauteslager, A., & Bakker, P. J. M. (2008) · PubMed · Cited by 41
Viitanen, J., Kuusisto, A. M., & Pirkko, N. (2011) · Studies in health technology and informatics · doi:10.3233/978-1-60750-709-3-333 · Cited by 37 · cited 1×
“Viitanen, Kuusisto, and Nykänen (2011) identified another classification of usability issues related to electronic nursing record systems.”
BackgroundLowry, S. Z., Ramaiah, M., Patterson, E. S., Brick, D., Gurses, A. P., Ozok, A., Simmons, D., & Gibbons, M. C. (2014) · Proceedings of the International Symposium on Human Factors and Ergonomics in Health Care · doi:10.1177/2327857914031028 · Cited by 37 · cited 2×
“In the most recent study, Lowry et al. (2014) used two human factors modeling methods (process mapping and goal–means decomposition diagrams) to improve EHR work flow integration in a larger clinical work flow.”
BackgroundMethodSingh, R. K. P. G., Servoss, T., Kalsman, M., Fox, C., & Singh, G. (2004) · Journal of Innovation in Health Informatics · doi:10.14236/jhi.v12i4.131 · Cited by 32 · cited 2×
“(Singh et al., 2004), and they see themselves as secretaries when they have to enter information into several forms.”
BackgroundMinimizing electronic health record patient-note mismatches
Wilcox, A. B., Chen, Y.-H., & Hripcsak, G. M. (2011) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2010-000068 · Cited by 32 · cited 2×
“As with orders being incorrectly filed for patients, Wilcox, Chen, and Hripcsak (2011) identified “patient–note mismatch” as a common type of EMR data entry error.”
BackgroundMethodUsability of a mobile electronic medical record prototype: a verbal protocol analysis
Wu, R. C., Orr, M. S., Chignell, M., & Straus, S. E. (2008) · Informatics for Health and Social Care · doi:10.1080/17538150802127223 · Cited by 29 · cited 1×
“Wu, Orr, Chignell, and Straus (2008) observed HCWs to have difficulty in reading information from EMR screens and in data entry, specifically with mobile systems.”
BackgroundThe electronic medical record: pros and cons
Ventura, M. L., Battan, A. M., Zorloni, C., Abbiati, L., Colombo, M., Farina, S., & Tagliabue, P. E. (2011) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767058.2011.607582 · Cited by 27 · cited 1×
“Related to this issue, Ventura et al. (2011) suggested that EMR systems should be equipped with CPOE dialogs in order to increase efficiency in use; however, they also noted that without patient and order verification dialogs, such systems could lead to prescription errors.”
BackgroundCaudill-Slosberg, M., & Weeks, W. B. (2005) · American Journal of Medical Quality · doi:10.1177/1062860605280196 · Cited by 26 · cited 7×
“Caudill-Slosberg and Weeks (2005) suggested that hazards associated with EMR use could also be identified by using techniques such as cause-and-effect diagrams or fishbone analysis.”
BackgroundMethodResultInfluentialDeveloping EMRs in Developing Countries
Chen, W., & Akay, M. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2091509 · Cited by 24 · cited 1×
“Chen and Akay (2011) identified a lack of interface customizability as a major issue in EMR system use in developing countries.”
BackgroundAddressing Human Computer Interaction Issues of Electronic Health Record in Clinical Encounters
Clarke, M. A., Steege, L. M. B., Moore, J. L., Belden, J. L., Koopman, R. J., & Kim, M. S. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-39241-2_42 · Cited by 20 · cited 5×
“Bowman (2013), in studying EHRs, observed that the complexity of interfaces contributes to user confusion and can cause errors.”
BackgroundInfluentialGlossary and Tables for Statistical Quality Control
Feder, P. I. (1984) · Technometrics · doi:10.2307/1268418 · Cited by 19
Using a unified usability framework to dramatically improve the usability of an EMR Module.
Harrington, C., Wood, R., Breuer, J., Pinzon, O. E., Howell, R., Pednekar, M., Zhu, M., & Zhang, J. (2011) · PubMed · Cited by 17
Electronic Medical Records Management Systems: An Overview
Edmund, L. C. S., Ramaiah, C. K., & Gulla, S. P. (2009) · DESIDOC Journal of Library & Information Technology · doi:10.14429/djlit.29.273 · Cited by 17
User interface optimization for an electronic medical record system.
Zheng, K., Padman, R., & Johnson, M. P. (2007) · PubMed · Cited by 16
Electronic Health Record System Risk Assessment: A Case Study from the MINET
Win, K. T., Phung, H. N., Young, L., Tran, M. H., Alcock, C., & Hillman, K. (2004) · Health Information Management Journal · doi:10.1177/183335830403300205 · Cited by 16 · cited 1×
“Win et al. (2004) also used the FMEA technique to identify potential failure modes in a health information sys-tem.”
MethodOn the Safety of Electronic Medical Records
Weber-Jahnke, J. H., & Mason-Blakley, F. (2012) · Lecture notes in computer science · doi:10.1007/978-3-642-32355-3_11 · Cited by 14 · cited 8×
“As mentioned earlier, Weber-Jahnke and Mason-Blakley (2012) recommended highlighting out-of-range values in EMR displays and providing warnings about “stale” results.”
BackgroundMethodResultInfluentialHagstedt, L. J., Rudebeck, C. E., & Petersson, G. (2011) · Journal of Innovation in Health Informatics · doi:10.14236/jhi.v19i3.809 · Cited by 14 · cited 2×
“In addition, Hagstedt, Rudebeck, and Petersson (2011) found that entering dosage values as free text may result in different interpretations at a pharmacy and ultimately increase the risk that a drug will be prescribed with the incorrect dosage.”
BackgroundResultElectronic Health Records: Physician's Perspective on Usability
Schumacher, R. M., Berkowitz, L., Abramson, P. R., & Liebovitz, D. (2010) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193121005401202 · Cited by 13 · cited 3×
“In another study, Schumacher et al. (2010) also observed interface navigation problems, specifically, excessive clicking to access functions, resulting in physician frustration.”
BackgroundMendez, E. O., & Ren, S. (2012) · IEEE International Conference on Electro Information Technology · doi:10.1109/eit.2012.6220696 · Cited by 13 · cited 1×
“Finally, Méndez and Ren (2012) found that, in general, reading and entering, for example, the vital signs of patients in an EMR is an error-prone and time consuming process.”
BackgroundHollin, I. L., Griffin, M., & Kachnowski, S. (2012) · Health Informatics Journal · doi:10.1177/1460458212437008 · Cited by 13 · cited 4×
“On the basis of field research in five health clinics, Hollin, Griffin, and Kachnowski (2012) identified eight aspects of usability relevant to EMR design.”
BackgroundInfluentialEnhancing Usability in EMR Screen Design
Zopf-Herling, K. M. (2011) · CIN Computers Informatics Nursing · doi:10.1097/ncn.0b013e31823ea54e · Cited by 13 · cited 3×
“Minimizing the number of user control actions to access functions was also one of the usability rules of thumb identified by Zopf-Herling (2011).”
BackgroundRealizing Electronic Medical Record Benefits: An Easy-to-Do Usability Study
Harrington, L., Porch, L., Acosta, K., & Wilkens, K. G. (2011) · JONA The Journal of Nursing Administration · doi:10.1097/nna.0b013e3182250b23 · Cited by 13
Yamamoto, L. G. (2014) · PubMed · Cited by 11
Electronic Medical Records Management Systems: An Overview
Edmund, L. C. S., Ramaiah, C. K., & Gulla, S. P. (2009) · DESIDOC Journal of Library & Information Technology · doi:10.14429/djlit.29.6.273 · Cited by 10 · cited 1×
“Edmund, Ramaiah, and Gulla (2009) observed that the use of EMRs has led to some improvements in health care, such as increased information exchange among providers.”
BackgroundUsability evaluation of Electronic Health Record
Pereira, R. P. G., Duarte, J., Salazar, M. M., Santos, M. F., Neves, J., Abelha, A., & Machado, J. M. (2012) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2012.6498049 · Cited by 10 · cited 3×
“For example, Pereira et al. (2012) found that the principle was violated in one EHR form.”
BackgroundA case study on better iconographic design in electronic medical records' user interface
Tasa, U. B., Özcan, O., Yantaç, A. E., & Ünlüer, A. A. (2008) · Informatics for Health and Social Care · doi:10.1080/17538150802127298 · Cited by 8
Vatnøy, T. K., Vabo, G. L., & Fossum, M. (2014) · Lecture notes in computer science · doi:10.1007/978-3-319-07293-7_67 · Cited by 7 · cited 2×
“Authors of other studies also referred to violations of the effective use of language principle in EMR design as a part of their usability evaluation (e.g., Indranoi et al., 2009; Vatnøy et al., 2014; Zopf-Herling, 2011).”
BackgroundPhysicians’ and Nurses’ Documenting Practices and Implications for Electronic Patient Record Design
Reuss, E. I., Naef, R., Keller, R., & Norrie, M. C. (2007) · Springer eBooks · doi:10.1007/978-3-540-76805-0_9 · Cited by 7 · cited 1×
“In an empirical investigation of physician and nurse practices in recording information with EPRs, Reuss, Naef, Keller, and Norrie (2007) found the majority of HCWs to identify a lack of flexible ways for entering information to be a usability issue.”
BackgroundRodriguez, N. J., Borges, J. A., Murillo, V., Ortiz, J., & Sands, D. Z. (2003) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.2002.1011405 · Cited by 7 · cited 1×
“Related to this finding, Rodriguez, Borges, Murillo, Ortiz, and Sands (2002) compared a graphics-based electronic patient record (EPR) with a text-based record in terms of the usability attributes of learnability, task efficiency, and user satisfaction.”
BackgroundUsing Design Structure Matrix for improving Electronic Medical Record usability
Kuqi, K., Eveleigh, T., Holzer, T. H., & Sarkani, S. (2012) · IEEE International Systems Conference (SysCon) · doi:10.1109/syscon.2012.6189484 · Cited by 6 · cited 1×
“For example, Kuqi, Eveleigh, Holzer, and Sarkani (2012) evaluated usability issues in EMR use and observed that poor design leads to user information overload.”
BackgroundDESIGNING A PHYSICIAN-FRIENDLY INTERFACE FOR AN ELECTRONIC MEDICAL RECORD SYSTEM
Craig, D., & Farrell, G. (2010) · International Conference on Health Informatics · doi:10.5220/0002746003240329 · Cited by 4 · cited 3×
“In the event that a special medication or dosage is needed, dialog design should include free-for-mat text entry (Craig & Farrell, 2010) for the clinician.”
BackgroundUsability assessment of an electronic health record in a comprehensive dental clinic
Suebnukarn, S., Rittipakorn, P., Thongyoi, B., Boonpitak, K., Wongsapai, M., & Pakdeesan, P. (2013) · SpringerPlus · doi:10.1186/2193-1801-2-220 · Cited by 4 · cited 1×
“In a more recent study, Suebnukarn et al. (2013) found mental workload to be a major usability issue in using EHRs.”
BackgroundDevelopment and Usability of iCare: An Electronic Health Record System
Indranoi, C., Wyatt, T. H., & Li, X. (2009) · Cited by 1
Research works printed but not linked: 12
- Bowman S., 2013, Perspectives in Health Information Management, 10, 1c
- Chin B., 2012, Hawaii Journal of Medicine and Public Health, 71, 50
- Graham T. A., 2008, AMIA annual symposium proceedings, 2008, 257
- Hagstedt L. J., 2011, Informatics in Primary Care, 19, 161
- Harrington C., 2011, AMIA annual symposium proceedings, 2011, 549
- Indranoi C., 2009, In Proceedings of the 2009 Industrial Engineering Research Conference, 797
- International Organization for Standardization, 1998, Ergonomic requirements for office work with visual display terminals (VDTs) — Part 11: Guidance on usability
- Jaspers M. W., 2008, Studies in Health Technology and Informatics, 136, 303
- Omdahl T. P., 1988, Reliability, availability, and maintainability dictionary
- Singh R., 2004, Informatics in Primary Care, 12, 235
- Suebnukran S., 2013, SpringPlus, 2, 1
- Zheng K., 2007, Studies in Health Technology and Informatics, 129, 1058
Cited by
Association of Electronic Health Record Design and Use Factors With Clinician Stress and Burnout
Kroth, P. J., Morioka-Douglas, N., Veres, S., Babbott, S., Poplau, S., Qeadan, F., Parshall, C., Corrigan, K., & Linzer, M. (2019) · JAMA Network Open · doi:10.1001/jamanetworkopen.2019.9609 · Cited by 333
Identifying electronic health record usability and safety challenges in pediatric settings
Ratwani, R. M., Savage, E., Will, A., Fong, A., Karavite, D., Muthu, N., Rivera, A. J., Gibson, C., Asmonga, D., Moscovitch, B., et al. (2018) · Health Affairs · doi:10.1377/hlthaff.2018.0699 · Cited by 163
Navigation in the electronic health record: A review of the safety and usability literature
Roman, L. C., Ancker, J. S., Johnson, S. B., & Senathirajah, Y. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.01.005 · Cited by 166
Why Is the Electronic Health Record So Challenging for Research and Clinical Care?
Holmes, J. H., Beinlich, J., Boland, M. R., Bowles, K. H., Chen, Y., Cook, T. S., Demiris, G., Draugelis, M., Fluharty, L., Gabriel, P. E., et al. (2021) · Methods of Information in Medicine · doi:10.1055/s-0041-1731784 · Cited by 117
Melnick, E. R., Harry, E., Sinsky, C. A., Dyrbye, L. N., Wang, H., Trockel, M. T., West, C. P., & Shanafelt, T. (2020) · Journal of Medical Internet Research · doi:10.2196/23382 · Cited by 100
Metadata
- Authors
- Zahabi, M., Kaber, D. B., & Swangnetr, M.
- Affiliations
- North Carolina State University (US)
- Khon Kaen University, Khon Kaen, Thailand
- Venue
- Human Factors: The Journal of the Human Factors and Ergonomics Society
- Publisher
- SAGE Publications
- Published
- 2015-03-23
- Volume
- 57
- Issue
- 5
- Pages
- 805-834
- ISSN
- 0018-7208 (ISSN-L)
- 1547-8181
- OpenAlex
- W2153072644
- Semantic Scholar
- 337add3ca4224d5d4244772ae3b95bba6f06cf97
- Cited by
- 240
- References
- 76
- Citations by year
- 2026: 21 · 2025: 16 · 2024: 17 · 2023: 17 · 2022: 21 · 2021: 35 · 2020: 33 · 2019: 26 · 2018: 16 · 2017: 23 · 2016: 14 · 2015: 1
- FWCI
- 34.60
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Human Factors The Journal of the Human Factors and Ergonomics Society (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (2 T42 OH008673-08)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Physical Sciences › Computer Science › Human-Computer Interaction › Usability and User Interface Design
- Health Sciences › Nursing › Research and Theory › Nursing Diagnosis and Documentation
- Keywords
- electronic health records, user interface usability, medical device safety, hazard identification, design guidelines, error prevention, cognitive load, feedback, clinical documentation, diagnostic process, data presentation
- MeSH terms
- Humans, Quality of Health Care, Safety, Software, User-Computer Interface, Guidelines as Topic, Medical Errors, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.