Automated Selection of DAB-labeled Tissue for Immunohistochemical Quantification
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The increased use of immunohistochemistry (IHC) in both clinical and basic research settings has led to the development of techniques for acquiring quantitative information from immunostains. Staining correlates with absolute protein levels and has been investigated as a clinical tool for patient diagnosis and prognosis. For these reasons, automated imaging methods have been developed in an attempt to standardize IHC analysis. We propose a novel imaging technique in which brightfield images of diaminobenzidene (DAB)-labeled antigens are converted to normalized blue images, allowing automated identification of positively stained tissue. A statistical analysis compared our method with seven previously published imaging techniques by measuring each one's agreement with manual analysis by two observers. Eighteen DAB-stained images showing a range of protein levels were used. Accuracy was assessed by calculating the percentage of pixels misclassified using each technique compared with a manual standard. Bland-Altman analysis was then used to show the extent to which misclassification affected staining quantification. Many of the techniques were inconsistent in classifying DAB staining due to background interference, but our method was statistically the most accurate and consistent across all staining levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PERIODATE-LYSINE-PARAFORMALDEHYDE FIXATIVE A NEW FIXATIVE FOR IMMUNOELECTRON MICROSCOPY
MCLEAN, I. W., & NAKANE, P. K. (1974) · Journal of Histochemistry & Cytochemistry · doi:10.1177/22.12.1077 · Cited by 3,798 · cited 1×
“The harvested tissue was fixed with paraformaldehyde– lysine–phosphate fixative (McLean and Nakane 1974), decalcified using ethylenediaminetetraacetic acid–glycerol (Bourque et al. 1993; Mori et al. 1988) for 5 weeks, washed to remove the glycerol, and frozen in OCT embedding medium (Tissue-Tek;…”
MethodQuantification of histochemical staining by color deconvolution.
Ruifrok, A. C. C., & Johnston, D. A. (2001) · PubMed · Cited by 2,568
Prognostic and predictive factors in breast cancer by immunohistochemical analysis.
Allred, D. C., Harvey, J. M., Berardo, M. D., & Gm, C. (1998) · PubMed · Cited by 2,143
Jähne, B. (1997) · Springer eBooks · doi:10.1007/978-3-662-03477-4 · Cited by 727
Statistics Notes: Measurement error and correlation coefficients
Bland, J. M., & Altman, D. G. (1996) · BMJ · doi:10.1136/bmj.313.7048.41 · Cited by 639 · cited 2×
“The mean manual value then has a 95% confidence interval of 1.96s (Bland and Altman 1996; Daly and Bourke 2000; King et al. 2002).”
BackgroundMethodInterpretation and Uses of Medical Statistics
Daly, L. E., & Bourke, G. J. (2000) · Wiley eBooks · doi:10.1002/9780470696750 · Cited by 558
Jacobs, T. W., Gown, A. M., Yaziji, H., Barnes, M. J., & Schnitt, S. J. (1999) · Journal of Clinical Oncology · doi:10.1200/jco.1999.17.7.1983 · Cited by 457
Venter, D., Kumar, S., Tuzi, N., & Gullick, W. (1987) · The Lancet · doi:10.1016/s0140-6736(87)92736-x · Cited by 404 · cited 2×
“A correlation between IHC staining and protein levels has been shown using accepted measurement methods, including Western blotting analysis (Venter et al. 1987; Podhajsky et al. 1997; Dias et al. 2000) and enzyme immunoassays (Aasmund- stad et al. 1992; Lehr et al. 1997; Bhatnagar et al. 1999;…”
BackgroundMethodLehr, H.-A., Mankoff, D. A., Corwin, D., Santeusanio, G., & Gown, A. M. (1997) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549704501112 · Cited by 308 · cited 7×
“…methods have been developed to rapidly differentiate DAB-stained tissue from background staining levels (Goto et al. 1992; Montironi et al. 1996; Lehr et al. 1997; Ruifrok 1997; Smejkal and Shainoff 1997; Ma and Lozanoff 1998; Kohlberger et al. 1999; Ruifrok and Johnston 2001; Vilaplana and…”
BackgroundMethodInfluentialInterpretation and Quantification of Immunostains
Seidal, T., Balaton, A. J., & Battifora, H. (2001) · The American Journal of Surgical Pathology · doi:10.1097/00000478-200109000-00013 · Cited by 205 · cited 5×
“In addition, quantitative IHC techniques have often yielded clinically important information regarding patient diagnosis, prognosis, or both (Seidal et al. 2001).”
BackgroundInfluentialDias, P., Chen, B., Dilday, B., Palmer, H., Hosoi, H., Singh, S., Wu, C., Li, X., Thompson, J., Parham, D., et al. (2000) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)64743-8 · Cited by 190 · cited 2×
“…IHC staining and protein levels has been shown using accepted measurement methods, including Western blotting analysis (Venter et al. 1987; Podhajsky et al. 1997; Dias et al. 2000) and enzyme immunoassays (Aasmund- stad et al. 1992; Lehr et al. 1997; Bhatnagar et al. 1999; Simone et al. 2000).”
BackgroundMethodMatkowskyj, K. A., Schonfeld, D., & Benya, R. V. (2000) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540004800216 · Cited by 152 · cited 2×
“…Huang et al. 1996; Montironi et al. 1996; Kohlberger et al. 1999; Lehr et al. 1997,2001; Ruifrok 1997; Smejkal and Shainoff 1997; Ma and Lozanoff 1998; Vilaplana and Lavaille 1999; Matkowskyj et al. 2000; Ruifrok and Johnston 2001; Underwood et al. 2001; King et al. 2002; McGinley et al. 2002).”
BackgroundGiatromanolaki, A. N., Koukourakis, M. I., Theodossiou, D., Barbatis, K., O'Byrne, K. J., Harris, A. L., & Gatter, K. C. (1997) · PubMed · Cited by 136
Sensitive Immunoassay of Tissue Cell Proteins Procured by Laser Capture Microdissection
Simone, N. L., Remaley, A. T., Charboneau, L., Petricoin, E. F., III, Glickman, J., Emmert‐Buck, M. R., Fleisher, T. A., & Liotta, L. A. (2000) · American Journal Of Pathology · doi:10.1016/s0002-9440(10)64749-9 · Cited by 136 · cited 2×
“…to correlate with protein measurements (Aasmundstad et al. 1992; Lehr et al. 1997; Podhajsky et al. 1997; Bhatnagar et al. 1999; Dias et al. 2000; Simone et al. 2000) and even DNA measures (Venter et al. 1987; Ratcliffe et al. 1997; Gerdes et al. 1998; Jacobs OD r,g,b( ) log10…”
BackgroundMethodHansen, S., Grabau, D., Rose, C., Bak, M., & Sørensen, F. B. (1998) · PubMed · Cited by 124
Assessment of HER2 status in breast cancer
Dowsett, M., Cooke, T., Ellis, I. O., Gullick, W., Gusterson, B. A., Mallon, E., & Walker, R. A. (2000) · European Journal of Cancer · doi:10.1016/s0959-8049(99)00264-6 · Cited by 107 · cited 1×
“Acceptance of protocol and analysis standards is essential for the comparison of results across laboratories (Allred et al. 1998; Grzybicki and Moore 1999; Dowsett et al. 2000; Braun and Harbeck 2001; Ermert et al. 2001; Hanna 2001; O’Leary 2001; Schnitt 2001; Williams et al. 2001).”
BackgroundA Technique for Quantitative Three-Dimensional Analysis of Microvascular Structure
Brey, E. M., King, T. W., Johnston, C. M., McIntire, L. V., Reece, G. P., & Patrick, C. (2002) · Microvascular Research · doi:10.1006/mvre.2002.2395 · Cited by 100 · cited 2×
“Anticancer Res 18:2529–2534 Giatromanolaki A, Koukourakis MI, Theodossiou D, Barbatis K, O’Byrne K, Harris AL, Gatter KC (1997) Comparative evaluation of angiogenesis assessment with anti-factor-VIII and antiCD31 immunostaining in non-small cell lung cancer.”
MethodSelf-citationvan der Laak, J. A. W. M., Pahlplatz, M. M. M., Hanselaar, A. G. J. M., & de Wilde, P. C. M. (2000) · Cytometry · doi:10.1002/(sici)1097-0320(20000401)39:4<275::aid-cyto5>3.0.co;2-8 · Cited by 91
Lehr, H. A., Jacobs, T. W., Yaziji, H., Schnitt, S. J., & Gown, A. M. (2001) · American Journal of Clinical Pathology · doi:10.1309/aj84-50ak-1x1b-1q4c · Cited by 81 · cited 2×
“…and even DNA measures (Venter et al. 1987; Ratcliffe et al. 1997; Gerdes et al. 1998; Jacobs OD r,g,b( ) log10 (Red,Green,Blue) (Red,Green,Blue)control ------------------------------------------------------- –= CD 3.63*b 2.60*r 1.28*g––= et al. 1999; Lehr et al. 2001) of highly amplified genes.”
BackgroundInfluentialBreast Cancer in the 21st Century: Neu Opportunities and Neu Challenges
Schnitt, S. J. (2001) · Modern Pathology · doi:10.1038/modpathol.3880288 · Cited by 80 · cited 1×
“Acceptance of protocol and analysis standards is essential for the comparison of results across laboratories (Allred et al. 1998; Grzybicki and Moore 1999; Dowsett et al. 2000; Braun and Harbeck 2001; Ermert et al. 2001; Hanna 2001; O’Leary 2001; Schnitt 2001; Williams et al. 2001).”
BackgroundA method to quantify glial fibrillary acidic protein immunoreactivity on the suprachiasmatic nucleus
Vilaplana, J., & Lavialle, M. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00016-3 · Cited by 68 · cited 4×
“…Huang et al. 1996; Montironi et al. 1996; Kohlberger et al. 1999; Lehr et al. 1997,2001; Ruifrok 1997; Smejkal and Shainoff 1997; Ma and Lozanoff 1998; Vilaplana and Lavaille 1999; Matkowskyj et al. 2000; Ruifrok and Johnston 2001; Underwood et al. 2001; King et al. 2002; McGinley et al. 2002).”
BackgroundMethodInfluentialHanna, W. M. (2001) · Oncology · doi:10.1159/000055398 · Cited by 58 · cited 1×
“Acceptance of protocol and analysis standards is essential for the comparison of results across laboratories (Allred et al. 1998; Grzybicki and Moore 1999; Dowsett et al. 2000; Braun and Harbeck 2001; Ermert et al. 2001; Hanna 2001; O’Leary 2001; Schnitt 2001; Williams et al. 2001).”
BackgroundUnderwood, R. A., Gibran, N. S., Muffley, L. A., Usui, M. L., & Olerud, J. E. (2001) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215540104901011 · Cited by 56 · cited 3×
“…Huang et al. 1996; Montironi et al. 1996; Kohlberger et al. 1999; Lehr et al. 1997,2001; Ruifrok 1997; Smejkal and Shainoff 1997; Ma and Lozanoff 1998; Vilaplana and Lavaille 1999; Matkowskyj et al. 2000; Ruifrok and Johnston 2001; Underwood et al. 2001; King et al. 2002; McGinley et al. 2002).”
BackgroundMethodHuang, X., Chen, S., & Tietz, E. I. (1996) · Journal of Histochemistry & Cytochemistry · doi:10.1177/44.9.8773563 · Cited by 42 · cited 2×
“A variety of computer-assisted methods have been developed to aid in the analysis of digital images of immunostains (Goto et al. 1992; Huang et al. 1996; Montironi et al. 1996; Kohlberger et al. 1999; Lehr et al. 1997,2001; Ruifrok 1997; Smejkal and Shainoff 1997; Ma and Lozanoff 1998; Vilaplana…”
BackgroundMethodA Quantitative Immunohistochemical Study of the Cellular Response to Crush Injury in Optic Nerve
Podhajsky, R. J., Bidanset, D. J., Caterson, B., & Blight, A. R. (1997) · Experimental Neurology · doi:10.1006/exnr.1996.6354 · Cited by 29 · cited 2×
“IHC staining levels have been shown to correlate with protein measurements (Aasmundstad et al. 1992; Lehr et al. 1997; Podhajsky et al. 1997; Bhatnagar et al. 1999; Dias et al. 2000; Simone et al. 2000) and even DNA measures (Venter et al. 1987; Ratcliffe et al. 1997; Gerdes et al. 1998; Jacobs OD…”
BackgroundMethodImplications of Prognostic Markers in Brain Tumors
Grzybicki, D. M., & Moore, S. A. (1999) · Clinics in Laboratory Medicine · doi:10.1016/s0272-2712(18)30093-3 · Cited by 24 · cited 1×
“Acceptance of protocol and analysis standards is essential for the comparison of results across laboratories (Allred et al. 1998; Grzybicki and Moore 1999; Dowsett et al. 2000; Braun and Harbeck 2001; Ermert et al. 2001; Hanna 2001; O’Leary 2001; Schnitt 2001; Williams et al. 2001).”
BackgroundMolecular markers for diagnosis, staging, and prognosis of bladder cancer.
Williams, S. G., Buscarini, M., & Stein, J. P. (2001) · PubMed · Cited by 22
Ma, W., & Lozanoff, S. (1999) · Biotechnic & Histochemistry · doi:10.3109/10520299909066470 · Cited by 12 · cited 17×
“Hue images may provide a more useful means for assessing color change and have been suggested to enhance the separation of DAB and hematoxylin staining (Ma and Lozanoff 1998).”
BackgroundMethodInfluentialDaly, L. E., & Bourke, G. J. (2000) · Wiley eBooks · doi:10.1002/9780470696750.ch12 · Cited by 12
Cited by
Varghese, F., Bukhari, A. B., Malhotra, R., & De, A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096801 · Cited by 1,318
“With the introduction of advanced digital image processing systems, the emergence of a number of both, commercial as well as freelyavailablecomputer-assistedsoftwareshavebeenintroducedin order to rally the high volume IHC analysis and scoring [1,5,7–14].”
MethodFedchenko, N., & Reifenrath, J. (2014) · Diagnostic Pathology · doi:10.1186/s13000-014-0221-9 · Cited by 808
Deubiquitinase USP9X stabilizes MCL1 and promotes tumour cell survival
Schwickart, M., Huang, X., Lill, J. R., Liu, J., Ferrando, R., French, D. M., Maecker, H., O’Rourke, K., Bazan, F., Eastham-Anderson, J., et al. (2010) · Nature · doi:10.1038/nature08646 · Cited by 628
Wu, T., Dejanovic, B., Gandham, V. D., Gogineni, A., Edmonds, R., Schauer, S., Srinivasan, K., Huntley, M. A., Wang, Y., Wang, T.-M., et al. (2019) · Cell Reports · doi:10.1016/j.celrep.2019.07.060 · Cited by 466
Álvaro, T., Lejeune, M., Salvadó, M. T., Bosch, R., García, J. F., Jaén, J., Banham, A. H., Roncador, G., Montalbán, C., & Piris, M. A. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-04-1869 · Cited by 450
Metadata
- Authors
- Brey, E. M., Lalani, Z., Johnston, C., Wong, M., McIntire, L. V., Duke, P. J., & Patrick, C. W.
- Venue
- Journal of Histochemistry & Cytochemistry
- Publisher
- SAGE Publications
- Published
- 2003-05
- Volume
- 51
- Issue
- 5
- Pages
- 575-584
- ISSN
- 0022-1554 (ISSN-L)
- 1551-5044
- OpenAlex
- W2130455044
- Cited by
- 200
- References
- 29
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.