Reliable Bioelectrical Impedance Analysis Estimate of Fat‐free Mass in Liver, Lung, and Heart Transplant Patients
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Background: Bioelectrical impedance analysis (BIA) can be valuable in evaluating the fat‐free (FFM) and fat masses (FM) in patients, provided that the BIA equation is valid in the subjects studied. The purpose of the clinical evaluation was to evaluate the applicability of a single BIA equation to predict FFM in pre‐ and posttransplant patients and to compare FFM and FM in transplant patients with healthy controls. Methods: Pre‐ and posttransplant liver, lung, and heart patients (159 men, 86 women) were measured by two methods—50‐kHz BIA‐derived FFM (FFM BIA) by Xitron instrument and DXA‐derived FFM (FFM DXA) by Hologic QDR‐4500 instrument—and compared with healthy controls (196 men, 129 women), aged 20 to 79 years. Results: The high correlation coefficient (r =.974), small bias (0.3 ± 2.3 kg), and small SEE (2.3 kg) suggest that BIA using the GENEVA equation is able to predict FFM in pre‐ and posttransplant patients. The study shows that the lower weight seen in transplant men and women than in controls was due to lower FFM, which was partially offset by higher FM in men but not in women. Furthermore, the higher weights in posttransplant than in pretransplant patients were due to higher FM and % FM that was confirmed by lower FFM/FM ratio in posttransplant patients. Conclusions: Single 50‐kHz frequency BIA permits measurement of FFM in pre‐ and posttransplant patients. (journal of Parenteral and Enteral Nutrition 25:45–51, 2001)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
Estimation of total body water by bioelectrical impedance analysis
Kushner, R., & Schoeller, D. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.3.417 · Cited by 772
Is the Impedance index (ht2/R) significant in predicting total body water?
Kushner, R., Schoeller, D., Fjeld, C., & Danford, L. (1992) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/56.5.835 · Cited by 374
Why bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361
Application of Bioelectrical Impedance Analysis to Elderly Populations
Roubenoff, R., Baumgartner, R. N., Harris, T. B., Dallal, G. E., Hannan, M. T., Economos, C. D., Stauber, P. M., Wilson, P. W. F., & Kiel, D. P. (1997) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/52a.3.m129 · Cited by 258
Body composition and exercise performance in patients with chronic obstructive pulmonary disease.
Schols, A. M., Mostert, R., Soeters, P. B., & Wouters, E. F. (1991) · Thorax · doi:10.1136/thx.46.10.695 · Cited by 230
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Self-citationBioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Self-citationPichard, C., Kyle, U. G., Morabia, A., Perrier, A., Vermeulen, B., & Unger, P. (2004) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/79.4.613 · Cited by 392
Self-citationKyle, U. G., Kossovsky, M. P., Karsegard, V. L., & Pichard, C. (2006) · Clinical Nutrition · doi:10.1016/j.clnu.2005.11.001 · Cited by 379
Self-citationKyle, U. G., Genton, L., Hans, D., & Pichard, C. (2003) · Clinical Nutrition · doi:10.1016/s0261-5614(03)00048-7 · Cited by 248
Self-citation
Metadata
- Authors
- Kyle, U. G., Genton, L., Mentha, G., Nicod, L., Slosman, D. O., & Pichard, C.
- Venue
- Journal of Parenteral and Enteral Nutrition
- Publisher
- Wiley
- Published
- 2001-03
- Volume
- 25
- Issue
- 2
- Pages
- 45-51
- ISSN
- 0148-6071 (ISSN-L)
- 1941-2444
- OpenAlex
- W1982972567
- Cited by
- 60
- References
- 9
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliable Bioelectrical Impedance Analysis Estimate of Fat‐free Mass in Liver, Lung, and Heart Transplant Patients. https://app.cochat.ai/papers/10.1177/014860710102500245
- The paper
- Kyle, U. G., Genton, L., Mentha, G., Nicod, L., Slosman, D. O., & Pichard, C. (2001). Reliable Bioelectrical Impedance Analysis Estimate of Fat‐free Mass in Liver, Lung, and Heart Transplant Patients. Journal of Parenteral and Enteral Nutrition. https://doi.org/10.1177/014860710102500245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.